Skip to content

Review pass 10 (2026-11-07)

Date 2026-11-07
Reviewed 0.15.0
Findings 10.01–10.95 (pass-9 identifiers kept where a finding was already known)
Released in 2026.11.0
Overview Audit history · Changelog

The tenth review pass ran against 0.15.0. Its change concept was decided on 2026-11-07 and recorded in the [Unreleased] block of the changelog; the work was carried out by parallel work streams, each of which wrote its release notes as a changelog fragment. The release notes of 2026.11.0 condense these fragments; the concept and the fragments are reproduced here verbatim.

Where this text comes from

This page was moved verbatim from CHANGELOG.md when the release notes were condensed in 2026.11.0 (source: commit 30a122d). Only the markup was adapted: reST roles are rendered as code or math, relative links point to the current pages, trailing whitespace is removed, and each block stands under a heading that names where it was published. Paths, test names and numbers are those of the time; the code has changed since.

Change concept (decided 2026-11-07)

Planned — review pass 10 (change concept, decided 2026-11-07)

Not yet implemented. This block records the change concept of the tenth review pass (2026-11-07, against 0.15.0) as decided on 2026-11-07. Findings are referenced as 10.NN; pass-9 identifiers (Fxx) are kept where an item was already known. Each item moves into Added / Changed / Fixed / Security / Removed below once it lands together with its test; whatever is still listed here when the release is cut moves to the Roadmap instead. Items marked ⚠ change numerical results.

One release, calendar versioning. All items below ship together in the first calendar-versioned release. The version scheme changes from SemVer (0.15.0) to CalVer YYYY.MM.MICRO (e.g. 2026.11.0; month unpadded and no hyphen, because PEP 440 drops leading zeros and reads 2026-11 as a post-release). MICRO counts further releases within the same month. CalVer carries no compatibility promise, so deprecations follow a written policy: a deprecated name keeps working, warns with DeprecationWarning, and is removed no earlier than two releases and six months after its announcement.

  • Versioning and release tooling: scripts/release.py computes the CalVer version from the release date, validates everything before it writes, and runs git in the repository root; tags become vYYYY.MM.MICRO.
  • Security (10.01): evaluate_spec passes impedance_formula from a BusType JSON to sympy.sympify, which evaluates Python code. Replace it by an allow-list parser that builds the SymPy expression from the AST (numbers, f, rho, j, pi, + − * / **, sqrt/exp/log, size and exponent bounds) and validate on load. groundinsight (local 0.6.0) already guards its formulas; its guard is re-verified against the same attack corpus and against every formula groundfield exports.
  • Packaging (10.02, 10.11): no top-level scripts package and no release console script in the wheel (the same collision exists in groundinsight); py.typed; polars dropped (never imported); profile.out untracked; poetry-core bounded.
  • Silent failures become errors (10.06, 10.43, 10.51, 10.66, 10.67): unknown attached_to / return_to names, worlds without a finite current source, magnitude=nan, cross_section <= 0, non-finite resistivities, zero-length geometry, an ideal conductor with discretize_segment_length, and VoltageSource (currently solved to zero) raise with a named parameter and a suggestion; a cross section above 1e-2 m² warns ("mm² given?"); worlds beyond HARD_LIMIT raise before any allocation unless max_segments is raised; inert settings warn.
  • ⚠ Two-terminal sources and measurement (F01/F30, 10.16, 10.17, 10.38): Source.return_to honoured by every backend through one shared injection step; leakage-free junction nodes; measurement leads re-wired through them (replacing the 5 cm pseudo-rods); FieldResult.input_impedance(source).
  • ⚠ Cross-layer electrodes (F02, 10.15, 10.32, 10.50): one current share per electrode and layer in image_2layer, cim and solve_mutual_*; interface slivers merged; Galerkin self-term.
  • ⚠ Concrete encasement (10.12–10.14): one mechanism — the solver always treats the concrete shell as a distributed series resistance; the lumped model only converts its input. Today the lumped shell is dropped by solve_mutual_matrix, solve_mutual_field and every world without a PEN service drop while the inflated wire radius is kept (−3 % to −29 % on a foundation's self-impedance). OrtsnetzLayout honours the shells. An impact study on representative AP1 sites compares the old and new numbers.
  • ⚠ Exact line-source kernel (10.28): default reaction-matrix and field kernel; the point kernel converges 0.9–1.9 % below the exact uniform-current solution. Engine(kernel="point") reproduces earlier numbers.
  • ⚠ Earth return (F32, F50, F52, 10.20, 10.24, 10.35–10.37, 10.45, 10.46): carson_series on the anti-parallel image baseline; Sommerfeld λ-grid resolves distant pairs; exact n >= 3 buried kernel; Neumann inductance also on lumped and single-segment conductors; consistent internal-inductance convention; opt-in skin effect for conductor resistance.
  • ⚠ Post-solve consistency (10.25, 10.26, 10.33, 10.34): FieldResult.potential and solve_mutual_* use the engine's series controls (today capped at 100 terms); length-weighted solve_mutual_matrix diagonal; backend check and an optional reciprocal off-diagonal; line-source evaluation near conductors.
  • ⚠ Safety (F13, F51, 10.21, 10.22, 10.42, 10.52): touch voltage over the electrode footprint; uniform-current caveat; the EN 50522 anchors are confirmed against EN 50522:2022 Table B.4 (DIN EN 50522:2023-10) and pinned as literals in the test; docstrings cite the current edition; optional body-impedance / additional-resistance model and spectrum touch voltage.
  • ⚠ Fits and export (10.18, 10.19, 10.27, 10.40, 10.41): quantity= on sweep and the rho-f helpers with the input impedance as default; passivity check before export; robust vector fitting with a 0 Hz sample; standard form with optional constant term and relative weights; readable exported formulas.
  • ⚠ Engines (10.23, 10.29–10.31, 10.47–10.49): floating passive clusters in the mom family (reciprocal transfer impedances); cim weighted read-back; fem marked experimental with guards; duplicated layers merged; cim, bem and image_nlayer become deprecated aliases; shared engine benchmark suite.
  • ⚠ Generators (F07, F08, F28, F47, F48, 10.39, 10.53–10.55, 10.78): one network plan and one materialiser behind TnNetworkGenerator and the layout builder; reproducible resolved configs; rotated mesh foundations split at crossings; per-footprint foundations; lead depth honoured; bounded and validated Overpass requests with atomic caching; MD5 marked usedforsecurity=False (identical digests — stored masks stay valid).
  • Performance (10.56–10.65): row-chunked kernels (memory from 96 B·N² to O(N)), one reaction-matrix evaluation per solve, direct matrix assembly in solve_mutual_matrix, vectorised two-layer series (optional numba extra), multi-frequency Sommerfeld assembly, chunked field evaluation, sweep(n_jobs=...), performance and memory regression tests.
  • Architecture (10.74–10.77, 10.79–10.81): one kernel module and one solve pipeline shared by all backends; backend registry with a common metadata core and provenance (F22); versioned save_result / load_result (F23); nested backend options.
  • Usability (10.68–10.73): typed electrode factories, consistent parameter names with aliases, English names for German identifiers with aliases, curated namespaces (gf.plot, gf.safety, gf.fit), FieldResult.to_dataframe(), complex-valued compare_engines over all frequencies.
  • Standards (10.80, 10.94, 10.95): ruff format, ruff lint with the NumPy docstring convention and a physics naming allow-list, mypy, pre-commit, CI jobs for lint, types, docs and Python 3.14; tests organised by feature with a finding marker; supply-chain hardening of the workflows (10.03, 10.04).
  • Documentation (10.82–10.93): tutorials / how-to / reference / explanation structure, versioned tutorial notebooks executed in CI, glossary, units and conventions, warnings catalogue, validation page, known limitations, factories in the API reference, corrections to the 0.15.0 release notes (F47, F48 and F53/F54 were listed as fixed but the code was unchanged; cim is not bit-identical to image_2layer on unequal segment lengths; the F16 entry describes the symptom of F08), a concise changelog with a list of releases that changed numbers.

Release notes of the work streams

The fragments are reproduced as the work streams wrote them (from changelog.d/ of the release branch); only reST roles would be adapted, and none occur. Each stream wrote its fragment against the state of the branch at that time, so a later stream may have changed what an earlier one describes.

Corrections (first adversarial audit of this release)

Three statements in the fragments below were found to be wrong; the release notes of 2026.11.0 carry the corrected wording:

  • coup1, references.pollaczek (10.45): R′ moves by up to +3.5 % in band (100/10 Ω·m, h₁ = 1 m, conductor at 3 m, 1 kHz; +1.4 % for 1000/30 Ω·m, h₁ = 5 m, conductor at 3 m in the upper layer), not by “up to +0.5 %”; X′ by up to −0.09 %, not “less than 0.02 %”.
  • coup1, exact removal of the additive image (10.46): only kernel-level numbers are quoted. At solver level (default sommerfeld earth return, point kernel; two 1 m rods in 100 Ω·m joined by a 95 mm² conductor) Im Z moves by +6.0 % for a conductor inclined by 30° and by +18.4 % (50 Hz) to +18.5 % (1 kHz) for a steep riser; Re Z is unchanged.
  • core1a, solver structure (10.75, 10.79): “every previously importable name of groundfield.solver.image remains importable” is false for private names and re-imports: the _discretize_* helpers, _grid_segments, the electrode classes and PointSource that the module re-imported, _galerkin_solve of bem and mom_sommerfeld, private helpers re-imported by the other solver modules, and the private Pollaczek kernels of coupling.sommerfeld_inductance are gone.
  • Several fragments of the first waves describe intermediate states that later streams changed: the default kernel became "line" (core2b, after core1a), touching="exact" and the anti-parallel carson_series baseline became the solver default (coup2, after coup1), cim, bem and image_nlayer became deprecated aliases (eng2), the 180° counter-source of the layout builder was replaced by the junction-based measurement loop (gen2, after core2a), the two passivity checks were merged (fitx, after post and secio), and touch_voltage_envelope replaced mesh_centres= by interior= (fitx).

Corrections (second adversarial audit of this release)

The second audit found these statements of the fragments below to be false at the time they were written; the fragments of the fix2* streams at the end of the page record the fixes, and the release notes carry the corrected wording:

  • core2b, interface slivers (10.32): dropping an interface cut that would leave a part shorter than the wire diameter ignored the contact with the other layer (a 4.5 m rod in 1000/30 Ω·m: 195.0 Ω with its tip 15.9 mm into the lower layer, 128.6 Ω at 16.1 mm); every cut is now kept (fix2solver).
  • core2b, “a world without a source stays solvable through Engine.solve (all results zero)”: only fem did; every backend now raises (fix2solver).
  • The segment budget (10.06): conductor sub-pieces were not counted (a 100 m PEN in 2000 pieces was predicted at 12 segments); the guard now counts the nodal system (fix2solver).
  • Floating clusters in solve_mutual_* (10.29): not only an accuracy change; the cost grew with the square of the number of bonded nodes (256 nodes: 24.3 s → 199.9 s); one factorisation now serves all excitations (fix2solver).
  • carson_series on the anti-parallel image (10.20): wrong for a pair on opposite sides of the surface (an overhead lead 1 m above a PEN at 0.7 m: mutual reactance 35.9 % low at 1 kHz) and outside Carson's per-metre domain (fix2coup).
  • Lumped inductive conductors (10.24): under sommerfeld a km-long lumped conductor was one 16 × 16 quadrature (3 km at 1 kHz: +13.4 % earth-return resistance, +11 % at solver level, no warning) (fix2coup).
  • fixsec, “parse cost bounded” (10.01): SymPy still expanded symbolic exp and fractional powers of large powers (67- to 75-character formulas ran longer than 60 s), and a literal of 320 nines raised OverflowError (fix2sec).
  • gen2, a shell with ρ_c = ρ_soil (10.12): a shell of any size switched a mesh foundation from one current owner to one per wire (largest touch voltage 232.3 → 221.2 V at 100 A) (fix2gen).
  • eng2, deprecated cim “bit-identical on every world compared” (10.76): it is bit-identical to image_2layer of the same release; through the alias it uses the new default line kernel (core2b), so a ring of r = 2 m in 100 Ω·m moves by +0.85 % against 0.15.0 (13.31207 → 13.42534 Ω).

Superseded by the third adversarial audit and the user's decisions

These statements of the fragments below no longer describe the release; the fragments at the end of the page and the release notes do:

  • core2b, solve_mutual_matrix: offdiag=None selected "probe" when probe points were given. The galerkin off-diagonal is the default of every call; probe points need offdiag="probe" (ddefaults, user decision Q15).
  • coup2 and fix1, Sommerfeld assembly: “the default stays the per-pair assembly”, “"exact" (default)”. The default is "tabulated"; "exact" is the per-pair rule (ddefaults, user decision Q16).
  • fitx and fix3solver, touch_voltage_envelope(interior=None) sampled mesh cells and ring centres (and the cells of generated mesh foundations) by default. The default samples no interior; interior="meshes" does (dsafety, user decision Q3).
  • post, long_duration=True for 80 V beyond 10 s. 80 V applies to every fault duration above 10 s; the keyword is gone (dsafety, user decision Q4).
  • secio / fitx, rho_at_fit = ρ₁ for layered soil. The convention is the effective resistivity effective_resistivity(soil) (drhoeff, user decision Q6).
  • fix2gen, the nearest-point tree of PEN cables (chained cabinets, drops hung on other drops). Every cabinet has its own cable and a drop taps the cable that feeds its building (fix3gen).
  • fix2solver, “the step at zero penetration is the onset of the contact”. It is a limit of the thin-wire model; a rod end within one wire radius of an interface warns (InterfaceContactWarning), and the interface diagonal no longer clamps at h₁/200 (fix3solver).
  • fix2coup, wires lying side by side were switched to touching wires as whole pairs, from one segment's view (order dependent); the rule acts pointwise and order-free, and the accuracy statements “5e-11”, “1e-9” and “≤ 1e-4” hold only where they were measured (fix3coup).

Stream infra: Release tooling, packaging and CI

Changed

  • Calendar versioning: releases are numbered YYYY.MM.MICRO in PEP 440 form (2026.11.0; month without leading zero, no hyphen; MICRO counts the earlier releases of the month; tags v2026.11.0). The deprecation policy is stated at the top of this changelog. Test: tests/test_release_script.py::test_calver_version_from_date_and_tags.
  • Release tool (10.09): python scripts/release.py calver [--date YYYY-MM-DD] [--dry-run] derives the version from the date and the existing tags; python scripts/release.py set X.Y.Z takes an explicit canonical PEP 440 calendar version (pre-releases such as 2026.11.0rc1 included). The tool updates pyproject.toml, __version__, CITATION.cff (version, date-released) and turns [Unreleased] into ## [X] - YYYY-MM-DD, then commits and tags; it never pushes. The major / minor / patch bumps and the options --no-push, --allow-dirty and --allow-empty-changelog are gone. Test: tests/test_release_script.py.
  • Package metadata (10.11): metadata moved from the legacy [tool.poetry] tables to [project] (PEP 621; license as SPDX expression MIT, PEP 639); explicit classifiers for Python 3.12, 3.13 and 3.14 (the auto-generated 3.15 classifier is gone), OS independent, Scientific/Engineering, Typing :: Typed; build backend bounded to poetry-core>=2.2.0,<3.0.0. Test: tests/test_packaging.py::test_metadata_uses_the_project_table.
  • Typed package (10.02): groundfield ships a py.typed marker, so type checkers use its annotations. Test: tests/test_packaging.py::test_wheel_contents.
  • Development standards (10.94, 10.80): ruff lint configuration (F, E, W, I, B, UP, D with NumPy convention, N with a physics naming allow-list, C901 with complexity 15), mypy configuration with the pydantic plugin, pre-commit hooks (ruff format, ruff check, nbstripout, file hygiene), ruff 0.17.4 and mypy 2.4.1 pinned in the dev group, black removed. CI runs lint, types (non-blocking), tests on Python 3.12, 3.13 and 3.14 with pytest -n auto and coverage, a strict docs build on pull requests, and a non-blocking weekly dependency and workflow audit.

Removed

  • polars dependency (10.11): it was never imported. It is still installed with the groundinsight extra, because groundinsight 0.3.0 requires it. Test: tests/test_packaging.py::test_polars_is_neither_a_dependency_nor_imported.
  • Console scripts and the top-level scripts package (10.02): the wheel no longer installs release, generate-third-party-licenses or a scripts package. Run the tools from a checkout: python scripts/release.py ..., python scripts/generate_third_party_licenses.py. Test: tests/test_packaging.py::test_no_scripts_package_and_no_console_scripts.

Security

  • Package collision with groundinsight (10.02): the v0.15.0 wheel installed the same scripts/release.py and release command as groundinsight 0.3.0; installing both overwrote one with the other and uninstalling one broke the other. The wheel now contains only groundfield/ and its metadata. Test: tests/test_packaging.py::test_wheel_contents.
  • CI supply chain (10.03): every workflow starts with permissions: {} and grants each job only what it needs; every action is pinned to a full commit SHA with the tag in a comment; checkouts do not persist credentials (except the docs deployment, which pushes gh-pages); snok/install-poetry and softprops/action-gh-release are replaced by a pinned pip install poetry and the GitHub CLI; tag names reach shell code only through environment variables. The release workflow checks that the tag equals the version in all three version files, runs the full CI as a gate before building, and keeps PyPI trusted publishing. zizmor 1.32.0 reports 26 findings on the v0.15.0 workflows and none on the new ones.
  • Locked dependencies (10.04): pip-audit on the exported lock (all groups and extras) found 100 known advisories in 8 packages; after updating pillow (13.0.0), tornado (6.6), urllib3 (2.8.0), pymdown-extensions (12.3), certifi (2026.10.23), idna (3.20), pytest (9.2.0) and mkdocs-material (9.8.1) it finds none. numpy, scipy, sympy, pydantic, matplotlib and pandas keep their locked versions.
  • MathJax (10.08): the documentation loaded MathJax from a floating cdn.jsdelivr.net/npm/mathjax@3 URL without integrity check. MathJax 3.2.2 is now vendored with the site (60 files byte-identical to the verified npm release, pinned by SHA256SUMS); the site loads no third-party JavaScript. Test: tests/test_docs_assets.py.
  • Release tool (10.09): the v0.15.0 tool ran git in the caller's working directory, rewrote the version files before it validated the changelog (an aborted run left bumped files behind), committed on a detached HEAD or onto an existing tag, and could not finalise a pre-release. It now runs git in the repository root, validates everything before it writes (clean tree, branch, tag, agreeing version files, non-empty [Unreleased]) and restores the files if the commit fails. Tests: tests/test_release_script.py (marked finding("10.09")).

Docs

  • Formula rendering: the MathJax configuration started a second typesetting pass concurrently with MathJax's own; every formula was typeset twice (the copy lands in the hidden assistive-MathML region), and pages that autoload a TeX extension (\boldsymbol in ADR-0003 and ADR-0004) failed with "Cannot read properties of null (reading 'replaceChild')". Re-typesetting after instant navigation is now serialised through MathJax.startup.promise.

Stream core1a: Exact line-source kernel, solver structure and memory

Added

  • Exact line-source kernel (10.28): Engine(kernel="line") treats every segment as a uniform line current (Galerkin form of the exact line potential ln((R1+R2+L)/(R1+R2-L))/L, self term (2/L)[asinh(L/a) - sqrt(1+(a/L)^2) + a/L], images with mirrored end points) for the reaction matrix, FieldResult.potential and solve_mutual_matrix / solve_mutual_field. Against the exact uniform-current resistance (100 Ω·m) a 3 m rod, a 10 m strip, a 10 × 10 m foundation and a 20 × 20 m grid agree within 0.0004 % at every segment length from 2 m to 0.125 m (point kernel: −0.4 … −1.7 %); a ring of 5 m radius converges monotonically as O(ds²) (−0.60 / −0.17 / −0.044 / −0.011 % at ds = 2 / 1 / 0.5 / 0.25 m; point kernel −0.95 % at every ds). The default stays kernel="point", which reproduces earlier numbers; backends outside the image family reject kernel="line". Results record metadata["kernel"]; PointSource gains an optional direction (results written before this release load unchanged and are evaluated with the point kernel). For 16 house grids (1 920 segments) a solve with the line kernel takes about 2.5× the time of the point kernel with numba installed and about 5× without. Test: tests/test_line_kernel.py.
  • Geometry queries on the electrode models (10.79): every electrode kind provides segments(ds, layer_interfaces=None), segment_count(ds), wire_polylines(), bounds(), total_length() and min_feature_length(); groundfield.geometry.WireSegments holds midpoints, lengths and tangents. The solver discretises through them (midpoints, lengths and tangents bit-identical to the previous discretiser), so diagnostics, plots and exports can use the same conventions instead of their own isinstance ladders. Test: tests/test_electrode_geometry.py.
  • Optional compiled kernels (10.58, 10.28): when numba is installed the Tagg/Sunde series matrix and the far-field term of the line kernel are evaluated by compiled kernels that give the same matrices bit for bit: the series about 3× faster than the numpy path on one core (1 200 segments, 148 images), the far-field term about 5× (1 920 segments). Tests: tests/test_kernel_performance.py::test_numba_series_kernel_is_bit_identical, tests/test_line_kernel.py::test_numba_far_field_block_is_bit_identical.

Changed

  • ⚠ Two-layer image series summed before the product (10.58): the series is accumulated image by image into one matrix and then multiplied with the currents, instead of one matrix product per image. Results of image_2layer (electrodes inside the upper layer) and cim move by floating-point round-off only: at most 7.3e-16 relative on the golden cases cim_rod_two_layer, cond_isolated_pen_sommerfeld_two_layer, defaults_two_layer_ring_auto, img2_grid_upper_resistive and img2_ring_rods_within_layer (all within_tol). The reaction matrices of solve_mutual_* and of the mom family are unchanged bit for bit. A 30-house two-layer network (3 669 segments, 11 frequencies) solved 10–15× faster in two back-to-back comparisons on the same machine (memory 1 236 → 219 MiB).
  • Solver structure (10.75, 10.79): solver/image.py (2 526 lines) is split into private modules (discretisation, guards, kernels, inductive assembly, topology, pipeline); solve_image and solve_image_2layer run through one pipeline and differ only in the Green's-function object; the Tagg/Sunde series is one ImageSeries object used by the solver, FieldResult.potential and solve_mutual_*. Every previously importable name of groundfield.solver.image remains importable. Numbers are unchanged (golden values bit-identical). Tests: tests/test_solver_structure.py, tests/test_image_pipeline.py.
  • The warning for ignored non-current sources of image and image_2layer uses the common text of the other backends; FieldResult.clusters lists the electrodes in world order.

Fixed

  • Memory of the image-family kernels (10.56): the kernels no longer build (N, N, 3) difference tensors (96 bytes per segment pair). A 30-house network (3 687 segments) peaks at 115 MiB instead of 1 248 MiB and solved about 10× faster in back-to-back runs on the same machine; an 80-house network (9 712 segments) solves in about 2 s with 773 MiB (before: about 8.4 GiB needed). With rods reaching the lower layer of a two-layer soil (ADR-0007 path) the 30-house network peaks at 510 MiB instead of 1 250 MiB. Results are bit-identical. Above 1 GiB per reaction matrix the kernels switch to row blocks (results then differ by round-off only). Tests: tests/test_kernel_performance.py::test_solve_memory_peak_is_bounded, tests/test_kernel_performance.py::test_cross_layer_solve_memory_peak_is_bounded.
  • Reaction matrix evaluated twice per solve (10.57): the segment potentials after the solve reuse the assembled matrix. Bit-identical. Test: tests/test_kernel_performance.py::test_one_reaction_matrix_assembly_per_solve.
  • solve_mutual_matrix built the reaction matrix as kernel(eye(N)) (10.59): the matrix is assembled directly; Z_G is bit-identical and a 20-house two-layer catalogue matrix (2 466 segments) was 23–31× faster in two back-to-back comparisons (memory 604 → 146 MiB). Test: tests/test_kernel_performance.py::test_mutual_matrix_without_identity_product.
  • FieldResult.potential unchunked (10.62): large evaluations run in row blocks; a 200 × 200 grid over 3 687 sources peaks at 17 MiB (v0.15.0 needs about 96 bytes per point·source pair, 13 GiB here). Two-layer evaluations share every 1/r block between real and imaginary part and skip an all-zero imaginary part. Evaluations up to 16 MiB of kernel are bit-identical. Test: tests/test_kernel_performance.py::test_potential_on_a_large_grid_is_memory_bounded.
  • Point-source arrays rebuilt on every potential() call (10.65): cached privately on the result (not serialised). Test: tests/test_kernel_performance.py::test_point_source_arrays_are_cached_and_invalidated.

Removed

  • Dead code (10.81): solver.image._potential_kernel, solver.image._segment_z_extent, solver.image_2layer._two_layer_potential_kernel and the empty module solver.field_study. Test: tests/test_solver_structure.py::test_dead_helpers_are_removed.

Stream core1b: Backend registry, metadata, provenance and result files

Added

  • Backend registry (10.74): groundfield.solver.registry with register_backend(name, solve_fn, *, capabilities, options_model=None, aliases=(), deprecated_alias_of=None, experimental=False, forward=None), get_backend, available_backends, unregister_backend, BackendCapabilities and BackendSpec. Engine.solve dispatches through the registry instead of an if-chain, so a backend is added without editing Engine.solve; the automatic forwarding of image to image_2layer / image_nlayer by soil model is kept. A deprecated alias warns with its replacement and the earliest removal (2027.5); an experimental backend warns once per process (ExperimentalBackendWarning). Tests: tests/test_backend_registry.py::test_new_backend_runs_without_editing_engine_solve, ::test_deprecated_alias_warns_with_replacement_and_removal_version, ::test_experimental_backend_warns_once_per_process, ::test_image_is_auto_forwarded_by_soil_model.
  • Capability check before the solve (10.74): a world the backend cannot represent (soil layer count, concrete-shell electrodes, an explicitly requested source kernel) raises BackendCapabilityError before any backend code runs and names the registered backends that can solve it; a stack of equal layers counts as the merged stack. A backend that solves the world with a simplification warns with BackendCapabilityWarning: fem reduces distributed and inductive conductors to lumped resistive branches, and every backend still returns the current of a source with return_to through remote earth. Tests: tests/test_backend_registry.py::test_capability_error_names_a_backend_that_can_solve_the_world, ::test_capability_check_runs_before_the_backend, ::test_two_terminal_source_warns_when_the_backend_ignores_return_to, ::test_fem_warns_when_it_reduces_a_distributed_conductor.
  • Metadata core (10.74): every result carries backend, effective_backend, kernel, groundfield_version, frequencies, n_segments, soil_kind, earth_inductive_model, solve_time_s, series and provenance (groundfield.solver.engine.CORE_METADATA_KEYS) next to the backend-specific keys, which are unchanged. series records the engine's image-series controls for the post-solve field evaluation. Test: tests/test_backend_registry.py::test_every_backend_reports_the_metadata_core.
  • Backend options (10.74): Engine.options, keyed by backend name and validated by MomSommerfeldOptions (mom_sommerfeld) and FemOptions (fem), with a did-you-mean message for misspelled names; Engine.backend_options(name) returns the options a backend runs with. Tests: tests/test_engine_options.py::test_nested_sommerfeld_options_reach_the_backend, ::test_misspelled_option_is_rejected_with_a_suggestion.
  • Provenance (10.77, F22): metadata["provenance"] of every solve holds the groundfield, Python, numpy, scipy and pydantic versions, the platform, the engine configuration, world_fingerprint (SHA-256 of the canonical world JSON, groundfield.io.world_fingerprint) and the UTC time of the solve. Tests: tests/test_result_persistence.py::test_every_solve_records_provenance, ::test_world_fingerprint_is_canonical_and_sensitive, ::test_fingerprint_describes_the_world_as_built.
  • Versioned result files (10.77, F23): groundfield.io.save_result / load_result write and read one standard-JSON file with the envelope {"format": "groundfield.result", "schema_version": 1, "written_by", "provenance", "result"} (no pickle, atomic write, no silent overwrite); a newer schema raises ResultFormatError. Tests: tests/test_result_persistence.py::test_save_and_load_result_round_trip, ::test_load_result_rejects_a_newer_schema.
  • FieldResult.to_dataframe() (10.69, 10.72): tidy table with one row per frequency and electrode (frequency_hz, electrode, cluster, potential_v, current_a, cluster_impedance_ohm); to_dataframe("sources") gives one row per frequency and source with the impressed current and the input impedance. pandas is imported on first use. Tests: tests/test_result_dataframe.py::test_electrode_table_is_tidy_and_matches_the_accessors, ::test_source_table_carries_the_input_impedance.

Changed

  • Engine.backend is validated against the registry (a plain str annotation; Backend stays the Literal of the built-in names for type hints). An unknown name raises with the closest registered name as suggestion. Test: tests/test_backend_registry.py::test_unknown_backend_name_suggests_the_closest_registered_one.
  • Unsupported worlds fail earlier: cim, bem, mom and image_nlayer on soils with three or more distinct layers, and every non-image backend on concrete-shell electrodes, now raise BackendCapabilityError from Engine.solve and list the backends that can. It subclasses ValueError and NotImplementedError, the types image_nlayer, cim, bem and the concrete-shell guard raised before; mom raised TypeError for three or more layers.
  • One default for the image-series cap (10.74): DEFAULT_IMAGE_MAX_TERMS = 300 and DEFAULT_IMAGE_SERIES_TOL = 1e-6 (in groundfield.solver.registry) are the engine defaults and are recorded on every result as metadata["series"]. The image-series controls stay common Engine fields because six backends and the post-solve layer read them. Test: tests/test_engine_options.py::test_series_default_is_one_documented_value.
  • Engine JSON: options replaces the four flat sommerfeld_* keys; engine JSON written by 0.15.0 still loads, silently when it carries the default values. Test: tests/test_engine_options.py::test_v0150_engine_json_loads_without_warnings.
  • Result JSON writes non-finite floats of typed fields as "Infinity" / "NaN" strings instead of null, and tagged objects in metadata (see the groundfield.solver.result module docstring), so it is standard JSON and round-trips exactly.
  • Warnings of the pre-flight resolution check of Engine.solve are attributed to the caller's line instead of a line inside groundfield.

Fixed

  • Lossy result JSON (10.77): metadata["penetration_depth"] lost its float keys and its inf, and numpy values in the metadata could not be serialised at all. Tests: tests/test_result_persistence.py::test_result_json_round_trip_is_lossless, ::test_numpy_and_non_json_metadata_survive_the_round_trip.
  • Backend options silently accepted for another backend (10.74): the sommerfeld_* fields were accepted by every backend without effect; options for a backend that will not run now warn (BackendOptionsWarning). Test: tests/test_engine_options.py::test_options_for_another_backend_warn.
  • fem knobs unreachable (10.74): n_radial, n_axial, r_far_factor, z_far_factor and far_field can now be set through Engine(options={"fem": {...}}). Tests: tests/test_engine_options.py::test_fem_knobs_are_reachable_through_engine_options, ::test_fem_far_field_option_reaches_the_solver.
  • Engine.solve let a backend rewrite the caller's sources (10.72): World.solve, Engine.solve and run_simulation now share one identity-preserving snapshot and restore of World.sources. Test: tests/test_solve_entry_points.py::test_every_entry_point_restores_the_sources.
  • Inert engine settings accepted silently (10.51): Engine.tolerance and Engine.max_iterations are read by no backend; a non-default value now warns. Test: tests/test_engine_options.py::test_tolerance_and_max_iterations_warn_that_they_have_no_effect.

Deprecated

  • Engine.tolerance and Engine.max_iterations (no effect): a non-default value or attribute access emits DeprecationWarning; removal no earlier than 2027.5.
  • The flat fields Engine.sommerfeld_lambda_max_factor, sommerfeld_epsabs, sommerfeld_epsrel and sommerfeld_max_osc_panels: use Engine(options={"mom_sommerfeld": {...}}) or MomSommerfeldOptions. They are still accepted (constructor, JSON, attribute read and write); removal no earlier than 2027.5. Test: tests/test_engine_options.py::test_flat_sommerfeld_fields_are_mapped_and_deprecated.
  • World.solve(snapshot_sources=False): every entry point takes the snapshot now, so the opt-out saves nothing; removal no earlier than 2027.5. Test: tests/test_solve_entry_points.py::test_snapshot_opt_out_is_deprecated.

Removed

  • The private, unreachable Engine._stub_result and Engine._dispatch (replaced by the registry; part of 10.81).

Stream secio: Formula security and the groundinsight export

Security

  • BusType impedance formulas are parsed, never executed (10.01): evaluate_spec passed impedance_formula to sympy.sympify, which evaluates the text as Python code, so a crafted BusType JSON file ran arbitrary code or exhausted memory (7**7**7*0+rho builds an integer of about 696 000 digits, 9**9**9**9 never finishes). A new allow-list parser (groundfield.io._formula) parses the text with ast and builds the SymPy expression itself: numbers, f, rho, j / I, pi, E, + - * /, ** with a literal exponent (at most 64 in magnitude) and sqrt / exp / log, after Unicode NFKC normalisation, ASCII only, at most 10 000 characters, 2 000 syntax nodes and nesting depth 100. Every number stays within 1e-300 to 1e300 and powers are checked before they are computed, which also stops towers such as (((10**60*f)**64)**64)**64 (the review prototype accepted this one after 24 to 46 s with a 15.7-million-digit integer). BusTypeSpec.from_dict and load_bustype_json validate the formula on load and raise EvaluateSpecError naming the offending element (a missing formula raises EvaluateSpecError instead of KeyError). All 384 formulas the 0.15.0 exporter wrote parse to identical values, so existing BusType files keep loading. The corpus tests/data/formula_corpus.json (115 accepted formulas with reference values, 79 rejected strings) is shared with groundinsight's guard. Tests: tests/test_formula_security.py::test_evaluate_spec_does_not_run_code_from_a_formula, tests/test_formula_security.py::test_every_rejected_formula_fails_on_load_within_bounds, tests/test_formula_security.py::test_every_rejected_formula_fails_in_evaluate_spec_within_bounds.

Added

  • Passivity check before BusType export (10.40): to_bustype_dict, save_bustype_json, to_bustype and save_bustype_to_db evaluate the exported formula from 0 Hz to twice the highest fitted frequency (dense linear and logarithmic grid, the samples and the midpoints between them, points around every pole; for the standard form over the fitted rho range) and refine the minima. metadata["passivity"] records passed, min_re_Z_Ohm, f_at_min_Hz, rho_at_min_Ohm_m and the checked ranges. Re Z < 0 emits NonPassiveFitWarning; the new keyword require_passive=True raises NonPassiveFitError (a ValueError) and writes nothing. Example from the review: a 4-pole fit of passive data (rms 4.4 mOhm) has Re Z = -0.0194 Ohm at 5.507 Hz between the 0 Hz and 50 Hz samples and is now flagged. Test: tests/test_io_groundinsight.py::test_in_band_non_passive_vector_fit_is_flagged_on_export.

Changed

  • ⚠ Readable exported formulas (10.73): vector fits are written as partial fractions with float coefficients, each rounded once to decimals significant digits with Python's correctly rounded formatting (identical on every platform), e.g. 28.4652054274 - 54.0434542796/(2*pi*f*j + 27.5749267026). The exporter no longer calls nsimplify (exact fractions with integers of up to 254 digits) and no longer merges the partial fractions into one rational function (sympy.simplify produced terms up to f**4). Formulas of 2 to 10 poles shrink from 273-622 to 126-469 characters, and the export takes 0.04-0.14 s instead of 0.39-2.23 s (same session, passivity check included). decimals must be a positive integer; values above 17 count as 17. Numbers move only at the rounding level, at most half a unit in the last printed digit per coefficient (round trip below 1e-10 relative at the default 12 digits). Affected: anyone comparing formula text, e.g. diffs of BusType JSON files. Golden cases: none moved (fit_rho_f_standard_sweep bustype/eval is bit-identical). Tests: tests/test_io_groundinsight.py::test_vector_fit_formula_prints_floats_not_long_rationals, tests/test_io_groundinsight.py::test_round_trip_accuracy_follows_decimals.

Fixed

  • Actionable rho_at_fit error for vector-fit exports (10.84): the documented save_bustype_json(fit, ...) call for a vector fit raised "rho_at_fit is required" without saying what to pass. rho_at_fit stays required for a VectorFitResult (the BusType records the soil resistivity it belongs to); all four export functions now raise the same ValueError naming the function, an example call and the layered-soil convention, before a file is written or groundinsight is imported, and rho_at_fit must be positive and finite. Test: tests/test_io_groundinsight.py::test_vector_fit_without_rho_at_fit_raises_an_actionable_error.
  • BusType provenance stamp: metadata["source"] read groundfield unknown when the package ran from a source checkout (and went stale under an editable install); it now uses groundfield.__version__ (review item R5-12). Test: tests/test_io_groundinsight.py::test_bustype_metadata_records_the_running_groundfield_version.

Internal

  • The groundinsight round-trip test for vector fits asserts 1e-9 (ADR-0008) instead of 1e-3; a new test compares evaluate_spec with groundinsight's compute_impedance to 1e-9 and skips without groundinsight (tests/test_io_groundinsight.py::test_evaluate_spec_matches_groundinsight_evaluation). The bridge tests no longer skip the whole module when groundinsight is missing.

Stream post: Safety, sweeps, fits and plots

Added

  • Prospective touch voltage (F51, 10.52): permissible_prospective_touch_voltage_en50522(t_f, *, R_H=0, R_F1=0, rho_s=None, HF=1, long_duration=False) implements EN 50522:2022, Annex B.4 / Equation (A.3): U_vTp = U_Tp(t_f) + I_B(t_f)/HF · R_A with R_A = R_H + R_F1 + 1.5 m⁻¹ · ρ_s and the body current of Table B.1. Test: tests/test_safety.py::test_prospective_touch_voltage_figure_b3_parameter_sets.
  • True-RMS touch voltage over a fault spectrum (10.52): touch_voltage_spectrum(result_or_results, world, *, electrode, currents, ...) scales the touch voltage of every harmonic with its fault current and returns sqrt(Σ|U_T,k|²) at one foot position (AP2 harmonic cases). Test: tests/test_safety.py::test_touch_voltage_spectrum_is_the_rms_of_the_scaled_harmonics.
  • 80 V for long-duration faults (10.42): permissible_touch_voltage_en50522(t_f, long_duration=True) returns the 80 V that EN 50522:2022 allows for current-flow durations considerably longer than 10 s (requires t_f > 10 s; math.inf accepted). The default keeps the 85 V end value of Table B.4. Test: tests/test_safety.py::test_en50522_long_duration_allows_80_volt.
  • sweep(n_jobs=...) (10.64): process pool (spawn, BLAS pinned to one thread per worker); rows in serial order, worker warnings re-issued, bit-identical to n_jobs=1 when the caller also runs a single-threaded BLAS. Callables must be importable (not lambdas or notebook functions; a clear TypeError says so). Test: tests/test_sweep.py::test_parallel_sweep_is_bit_identical_to_the_serial_sweep.
  • check_passivity(fit, f_max, n=...) (10.41, 10.40): returns a PassivityReport (passed, min_re_Z, f_at_min, as_dict()); dense grid plus pole frequencies plus bounded refinement for vector fits, exact corner check for standard-form fits. It finds the −0.019 Ω dip at 5.5 Hz of the review's 4-pole fit. The export bridge has its own check (SEC/IO); the two are to be unified. Test: tests/test_vector_fitting.py::test_check_passivity_finds_an_in_band_violation_between_samples.
  • Plot components (10.73): plot_potential_contour, plot_potential_profile, plot_potential_radial and plot_surface_potential take component="real" | "imag" | "abs" | "phase". Test: tests/test_plotting.py::test_profile_plots_and_labels_the_requested_component.
  • read_csv_with_provenance(path) (10.73): reads the CSV files of groundfield.io.csv and returns the table plus the provenance header. Test: tests/test_io_csv.py::test_csv_files_carry_a_provenance_header.
  • New names: UniformCurrentFieldWarning, NEAR_FIELD_DISTANCE_M, RhoFStandardQualityWarning, VectorFitQualityWarning, PassivityReport; fields RhoFStandardFit.k0, .max_relative, .weights, .quantity and VectorFitResult.rms_relative, .quantity; keywords touch_voltage(anchor=), touch_voltage_envelope(anchor=, mesh_centres=, return_points=), step_voltage(world=), vector_fit(rms_tol=).

Changed

  • ⚠ Input impedance is the default of sweep, convergence_study and the rho-f exporters (10.18, 10.19): all take quantity="input" | "cluster" | "electrode" and source=. "input" (default) is the driving-point impedance (φ_attached − φ_return)/I_source; the v0.15.0 behaviour is quantity="cluster" for sweep / convergence_study and quantity="electrode" for rho_f_from_field_result / rho_f_standard_from_results (electrode_name is now optional). Numbers move wherever conductors carry current out of the feeding cluster: the cluster impedance of a station was 1.26 / 1.79 / 3.09 times the input impedance with 1 / 3 / 8 houses on a PEN, and the exporters fitted a ring with two bonded rods 17 % too high. Affected: groundinsight BusTypes exported with the rho-f helpers and sweeps of TN worlds; the AP1 catalogue is not affected (it computes its own driving-point impedance). With several current sources source= is now required (v0.15.0 silently used the first). Golden cases: fit_rho_f_standard_sweep (model halves: the two rods act in parallel through the PEN). Test: tests/test_impedance_quantity.py::test_sweep_default_reports_the_input_impedance.
  • ⚠ Standard rho-f form with constant term and relative weights (10.27): fit_rho_f_standard fits Z = k0 + k1 ρ + (k2 + j k3) f + (k4 + j k5) f ρ with k0=True and weights="relative" (1/|Z|) by default, reports max_relative (worst pointwise relative error) next to rms_relative and warns with RhoFStandardQualityWarning above 5 %. In ρ₁ sweeps of two-layer soil the worst pointwise error drops from 15–27 % (ring) and 43 % (AP1-like station) to 0.8–3.3 % and 6.2 %; homogeneous single-electrode sweeps are unchanged (k0 → 0). Exported formulas gain the constant term. k0=False, weights="uniform" reproduces v0.15.0 bit for bit. Affected: rho-f formulas exported to groundinsight, including AP1 exports (the stored samples are unchanged). Golden cases: fit_rho_f_standard_sweep. Test: tests/test_rho_f_standard.py::test_two_layer_ring_sweep_is_fitted_within_five_percent.
  • CSV files (10.73): the electrode and cluster tables gain a frequency_Hz column, every file starts with # key: value provenance lines (groundfield version, UTC time, backend, frequency, solve provenance when present), and the writers raise FileExistsError instead of overwriting unless overwrite=True. Read with read_csv_with_provenance or pandas.read_csv(path, comment="#"); provenance=False writes a plain CSV. Test: tests/test_io_csv.py::test_csv_writers_refuse_to_overwrite.
  • Plot labels (10.73): potential plots label the drawn component (Re φ in V for the default) instead of Potential φ in V. Test: tests/test_plotting.py::test_default_component_is_the_real_part_with_an_honest_label.
  • split_factor (10.18) divides by the source current of the solve (snapshot in FieldResult.sources) instead of the world's current source; the current-balance tables document that their impedances are cluster / electrode impedances, related to the input impedance by Z_in = s · Z_cluster. Test: tests/test_impedance_quantity.py::test_split_factor_uses_the_solved_source_current.

Fixed

  • ⚠ Touch voltage anchored at the electrode centre (F13, 10.21): touch_voltage and touch_voltage_envelope measured the 1 m from the connection point, so for a 20 m × 20 m grid (100 A, 100 Ω·m) the feet stood above the grid: 9.92 V instead of 69.6 V at +x, envelope 9.92 V instead of 111.4 V; a 4-arm star 275 V instead of 818 V beyond the arm tip. The feet now stand distance from the nearest wire of the electrode's footprint, on the side given by direction; the envelope walks that offset curve and adds the mesh centres of mesh / grid electrodes. anchor="connection_point" reproduces v0.15.0; rods are unchanged. Affected: touch-voltage assessments of grids, meshes, stars, strips, polylines and rings (rings at +x unchanged). Golden cases: img_mixed_cluster_hom (safety/touch_1m: strip ×3.2, star ×2.1). Test: tests/test_touch_voltage_footprint.py::test_grid_envelope_covers_the_one_metre_offset_curve.
  • Uniform-current field caveat (10.22): touch and step voltages from the image family (one uniform current per electrode) near grids, meshes, stars, strips, open polylines and bonded clusters deviate from mom by up to +19 % (touch) and −21 % (step, non-conservative) 1 m outside a 20 m grid corner; rings, rods and closed loops agree within 1 %. touch_voltage*, step_voltage and touch_voltage_spectrum now emit UniformCurrentFieldWarning once per call when a uniform-current result is evaluated within 5 m of such an electrode. Test: tests/test_touch_voltage_footprint.py::test_uniform_current_backend_warns_once_per_call_near_a_grid.
  • EN 50522 permissible touch voltage (F44, 10.42): the test compared the interpolant with the constant it interpolates; it now checks literals from EN 50522:2022, Table B.4 (DIN EN 50522 (VDE 0101-2):2023-10). The module values were confirmed against the standard and do not change; the deviations quoted in the review came from a secondary reproduction. Docstrings cite the 2022 edition (Table B.4, Figure 8) instead of "EN 50522:2010, Figure B.3" and no longer call it a low-voltage curve. Test: tests/test_safety.py::test_en50522_docstrings_cite_the_current_edition.
  • Vector fit collapse with a 0 Hz sample (10.41): a 0 Hz sample with an imaginary part (measured or averaged data) made the pole relocation move a pole onto the origin; the fit collapsed to Z ≈ 0 (relative rms 0.99 in 20 of 20 noisy data sets, no warning) or numpy raised LinAlgError. 0 Hz samples are now projected onto their real part (bit-neutral for real DC samples), an imaginary DC part above 0.1 % warns, a relative rms above rms_tol (1 %) warns with VectorFitQualityWarning, and solver failures raise ValueError. Test: tests/test_vector_fitting.py::test_dc_sample_with_imaginary_part_does_not_collapse_the_fit.
  • VTK header injection and float precision (10.10): a newline in world.name corrupted the legacy VTK header, and float declarations quantised UTM northings (5.2e6–6.2e6 m) by up to 0.25 m. The header line is sanitised and limited to 256 bytes; POINTS and SCALARS are double; the z-down convention is documented. Tests: tests/test_io_vtk.py::test_world_name_cannot_break_the_header, tests/test_io_vtk.py::test_points_are_double_precision_at_utm_scale.

Stream api: Factories, namespaces and soil parameter names

Added

  • Typed factories (10.68): create_electrode has one @overload per electrode kind and returns the concrete class (create_electrode(world, "ring", ...) is a RingElectrode), so IDEs show the parameters of the chosen kind and mypy reports a misspelled kind or keyword. Every string option of the factories is a Literal type: ElectrodeKind, SourceKind and KernelKind (new, in groundfield.api), and Backend, EarthInductiveModel, ConductorType, SoilCoupling, InductanceModel where they are defined. mypy now finds all four typos of the review example (wrong kind, wrong keyword, coupling_to_soil="galvanik", kind="Current"); it found none before. Test: tests/test_api_factories.py::test_mypy_finds_the_four_typos.
  • "Did you mean …?" errors (10.68): an unknown electrode kind (ValueError), an unknown keyword of a kind (TypeError, naming the kinds that do have it), an unknown source kind (ValueError) and an unknown electrode name as a conductor end (KeyError) name the closest valid names. Tests: tests/test_api_factories.py::test_unknown_electrode_kind_suggests_the_closest, ::test_unknown_electrode_keyword_suggests_the_closest, ::test_keyword_of_another_kind_is_explained, ::test_unknown_source_kind_suggests_the_closest, ::test_unknown_conductor_end_suggests_the_closest.
  • Curated namespaces (10.72): gf.plot (all plot helpers), gf.safety (touch and step voltages, EN 50522 limit) and gf.fit (vector fitting and the rho-f standard form) are new modules (groundfield.plot, groundfield.safety, groundfield.fit); gf.io groups the export. They hold the same objects as the flat names, which keep working; dir(gf) lists the namespaces. Test: tests/test_package_namespace.py::test_namespace_is_an_importable_module.
  • create_engine(kernel=...): chooses the field / reaction-matrix kernel ("point" or "line", KernelKind). Test: tests/test_api_factories.py::test_create_engine_accepts_the_point_kernel.
  • groundfield.utils: suggest, did_you_mean, warn_deprecated, warn_inert, InertConfigurationWarning (a UserWarning), REMOVAL_VERSION ("2027.5"). Deprecation and inert-configuration warnings point at the caller's line and are not emitted when groundfield's own code is the caller. Test: tests/test_utils_helpers.py::test_helpers_stay_silent_for_groundfield_callers.

Changed

  • Faster import groundfield (10.72): post-processing, IO, generators, the geo ingest, references, cross-engine validation and diagnostics are imported on first use (PEP 562); pandas, matplotlib, sympy and scipy are no longer loaded at startup. Median import time 798 ms → 223 ms and 1169 → 346 loaded modules (15 fresh interpreters, shared 2-core sandbox). __all__ is unchanged. Test: tests/test_package_namespace.py::test_import_does_not_load_heavy_dependencies.
  • Soil parameter names (10.69): the model layer uses the literature symbols — HomogeneousSoil.rho, SoilLayer.rho, SoilLayer.h (TwoLayerSoil.rho_1, rho_2, h_1 unchanged). The canonical world JSON writes rho / h; JSON written by 0.15.0 still loads. No numerical change. Golden: gen_layout_builder (world/json only). Test: tests/test_soil_models.py::test_world_json_written_by_v0150_loads.
  • create_electrode with an unknown keyword raises TypeError (was a pydantic ValidationError), like the other factories, whose explicit signatures always raised TypeError.
  • create_engine forwards only the arguments you pass; everything else takes the Engine default (single source of the defaults). create_engine() builds the same engine as Engine(). Test: tests/test_api_factories.py::test_create_engine_forwards_only_explicit_arguments.
  • Soil models validate assignment, and SoilModel is a union discriminated by kind (inferred from the keys when a mapping omits it), so a soil is validated once and errors name the selected model.
  • model_copy(update=...) of a soil model rejects unknown keys (a misspelled key was silently stored next to the fields and the copy kept the old value). Test: tests/test_soil_models.py::test_model_copy_rejects_unknown_fields.
  • run_simulation(world, engine) is documented and tested as world.solve(engine), with the same source-snapshot semantics. Test: tests/test_api_factories.py::test_run_simulation_has_world_solve_semantics.

Fixed

  • Non-finite soil parameters (10.67): resistivity = inf, rho_1 = inf, rho_2 = inf, h_1 = inf, an infinite layer thickness or relative_permittivity were accepted; an infinite resistivity then failed inside the solver with LinAlgError: Singular matrix. They are now rejected at construction and on assignment, naming the parameter. Tests: tests/test_soil_models.py::test_soil_parameters_must_be_finite_and_positive, ::test_assignment_is_validated.
  • MultiLayerSoil structure errors (10.67): an empty stack, a single layer with a finite thickness, a half-space above the bottom and a finite bottom layer each raise a message that names the layer and the fix; a one-layer stack with h=None stays a valid homogeneous half-space. Test: tests/test_soil_models.py::test_multilayer_structure_errors_are_clear.
  • Inert settings were silent (10.51 part, F57): a non-default BoundaryConditions field set through the constructor, create_world(boundary=...) or a world JSON, and a non-default soil relative_permittivity, now warn with InertConfigurationWarning. No backend reads them: with every boundary field changed, all eight backends solve bit-identically, and ε_r = 1 and 81 give identical impedances (below 1 kHz the displacement current is at most ωε₀ε_rρ = 4.5·10⁻³ of the conduction current for ρ = 1000 Ω·m, ε_r = 81). World.set_boundary_conditions keeps its single warning. Tests: tests/test_boundary_conditions.py::test_non_default_field_warns_on_construction, ::test_boundary_conditions_are_inert_in_every_backend, tests/test_soil_models.py::test_non_default_relative_permittivity_warns.
  • annotations leaked into the top-level namespace (10.72): gf.annotations (the __future__ feature object) is gone. Test: tests/test_package_namespace.py::test_annotations_does_not_leak.

Deprecated

Old soil parameter names (10.69). They keep working as keyword, JSON key, attribute and model_copy(update=...) key, warn with DeprecationWarning, and will be removed in 2027.5 at the earliest. Passing an old and its new name together raises. Type checkers already report the old keywords (only the canonical names are part of the typed signature); at run time they keep working.

Deprecated Replacement
HomogeneousSoil(resistivity=...), HomogeneousSoil.resistivity rho
SoilLayer(resistivity=...), SoilLayer.resistivity rho
SoilLayer(thickness=...), SoilLayer.thickness h

Test: tests/test_soil_models.py::test_old_keyword_warns_and_maps_to_canonical_field.

Stream gen1: Generators: network plan, footprints, reproducibility

Added

  • Network plan (10.78): NetworkPlan with PlannedSite, PlannedElectrode, PlannedJunction, PlannedBranch, ConductorParameters, PlannedMeasurement and PlannedSource is the pure-data description of one realisation (sites with concrete electrodes, PEN junctions, cables, measurement set-up, sources, soil). TnNetworkGenerator.plan() and LvNetworkLayout.plan() produce it, materialise_plan(plan) turns it into a World; build() / to_world() are plan + materialise. A plan round-trips through JSON and rebuilds the same world. GroundingSystemSpec.resolve_electrodes, plan_site and with_footprint expose the steps of build_at. Test: tests/test_network_plan.py.
  • Foundation outline of the layout builder (10.54): LvNetworkLayout.to_world and plan take foundation_outline: "ombr" (default, oriented minimum bounding rectangle of the footprint, the rule of the OSM placement of TnNetworkGenerator), "polygon" (ring along the real outline, DIN 18014, ring-style specs only) or "spec" (the fixed spec geometry of v0.15.0). Test: tests/test_footprint_foundations.py.
  • Explicit OSM building-tag filter: every building=* value is a footprint by default (also garage, shed and building=no), as before. parse_overpass_payload, query_and_project and LvNetworkLayout.from_osm take exclude_building_tags; groundfield.geo.NON_SERVICE_BUILDING_TAGS (carport, container, garage, garages, greenhouse, hut, no, roof, ruins, shed, shelter, tent) is the documented opt-in set. Test: tests/test_overpass_ingest.py::test_building_tag_filter_drops_non_service_buildings.
  • Reproducible generator draws (10.53): TnNetworkGenerator.build() and plan() accept rng= (seed or numpy.random.Generator).

Changed

  • One network plan and one materialiser (10.78): both front-ends (TnNetworkGenerator, LvNetworkLayout) produce a NetworkPlan; one module (groundfield.generators.materialise) builds foundations and their concrete shells, PEN junctions, PEN and service cables, the measurement loop and the sources. The layout module (ortsnetz_builder.py, about 2700 lines) is split into the package groundfield.generators.layout (model, routing, measurement, penetration, plot). Worlds are unchanged: 18 of 20 reference worlds are byte-identical to v0.15.0, the other two list the same conductors in another order and solve bit-identically; the refactor alone passes all golden values in strict mode. Test: tests/test_network_plan.py::test_tn_build_is_materialised_plan.
  • English names in the generator layer (10.69): see Deprecated for the full table. Generated element names (trafo_*, kvs_*, house_*) are data and stay unchanged, so stored worlds and results keep their keys.
  • ⚠ sample_world collapses nested distributions once per realisation (10.53): as documented, cfg.sample(rng) now replaces every distribution of the config tree, also those inside the electrode specs of a building type, so all buildings of a type share the drawn value in sample_world. v0.15.0 left these to per-building draws while reporting the config as resolved. build() on an unresolved config still draws per building; plain presence_prob and jitter_m still draw per site. Affected: sample_world realisations of configs with distributions inside specs. Golden cases: none moved.
  • Overpass retries: also on HTTP 503, honouring Retry-After (capped at 60 s); max_retries is limited to 5. Non-integer timeout_s raises TypeError (it is part of the query text). Test: tests/test_overpass_ingest.py::test_retries_honour_retry_after_and_are_bounded.

Fixed

  • Resolved configs replay their realisation (10.53, F07): cfg.sample() left distributions in nested specs and in building_counts; replays of the "resolved" config with seeds 0/1/2 gave 15/15/9 electrodes at 337/280/168 Ohm m instead of 15 electrodes at 331 Ohm m. Every distribution is now resolved (dicts in sorted key order), and sample_world(rng) draws the whole realisation from rng (the construction seed gave 5 vs 7 houses for the same rng). Test: tests/test_generator_reproducibility.py::test_resolved_config_replays_the_world_for_any_seed.
  • ⚠ Stable penetration mask without OSM ids (10.53): LvNetworkLayout.foundation_mask keyed footprints without osm_id by their list index; reversing the list changed the equipped houses and Z by 2.8 %. They are now keyed by their outline; footprints with osm_id keep their keys, so stored masks of OSM layouts stay valid. Affected: masks of footprints without osm_id at penetration below 1. Golden cases: none moved. Test: tests/test_generator_reproducibility.py::test_mask_without_osm_id_ignores_footprint_order.
  • ⚠ Layout foundations follow the building footprints (10.54, F28): LvNetworkLayout.to_world gave every house the same 10 x 10 m foundation at the footprint centroid. Foundations now take size, orientation and centre from the footprint (oriented minimum bounding rectangle), like the OSM placement of TnNetworkGenerator. In three test streets (8 houses, 100 Ohm m, 50 Hz, image backend) the substation impedance moves by 0 % (10 x 10 m squares), +0.6 % (12 x 9 m houses rotated by 0 to 35 deg) and +5.2 % (6 x 4 m garages alternating with 30 x 15 m blocks). Affected: every layout world whose footprints are not 10 x 10 m axis-aligned squares; foundation_outline="spec" reproduces v0.15.0. Golden cases: gen_layout_builder unchanged (10 x 10 m squares). Test: tests/test_footprint_foundations.py::test_foundation_size_follows_the_footprint.
  • ⚠ Rotated mesh foundations without the singularity clamp (10.39): rotated mesh foundations were built from full-length strips whose segment midpoints could coincide at the crossings; the solver's 1 mm clamp then made a 10 x 10 m, 2 x 2 mesh at 30 deg 11.8 % too high at a segment length of 2.0 m and 11.0 % at 1.5 m (no error at 2.5 m or 1.0 m). Crossed wires are now polylines with a vertex at every crossing, so crossings fall on segment ends as in GridMeshElectrode; ring-style foundations keep their four strips. The oriented bounding rectangle of a square reports the axis closest to +x, and a foundation at a multiple of 90 deg is built on the axis-aligned path: mesh foundations of squares and north-south rectangles change by +1.0 to +1.2 % (or -9.5 % where the clamp fired), ring foundations by less than 0.002 %. Note: with the uniform-current image backend a rotated mesh stays about 1.1 % below the axis-aligned mesh of the same rectangle (six wires with one current each instead of one); mom and bem give the same value for both, closer to the rotated one. Affected: mesh-style foundations on rotated or right-angle footprints (OSM placement, layout builder). Golden cases: none moved. Test: tests/test_rotated_foundations.py::test_rotated_mesh_has_no_clamp_and_converges_smoothly.
  • Jitter distribution (10.55, F47): ManhattanGridPlacement(jitter_m=Uniform(...)) raised TypeError ("Unable to apply constraint ge"); the bound now applies to the float only, a distribution is drawn once per site and a draw of 0 or less leaves the site on its grid point. Test: tests/test_placement.py::test_manhattan_grid_jitter_accepts_a_distribution.
  • ⚠ Measurement leads at their configured depth (10.55, F48): MeasurementLeadConfig.depth_m was drawn and discarded: buried and overhead leads ran on the same diagonal from the substation ring (z = 0.6 m) to the auxiliary rod head (z = 0). A lead now runs horizontally at z = depth_m (z > 0 below the surface) between the anchors and stays connected to both; depth_m = 0 is placed 0.1 m above ground (SURFACE_LEAD_HEIGHT_M; the surface plane is singular for the image kernels and the Sommerfeld kernel degrades within about ten wire radii of it), a galvanic lead above ground is rejected. In the golden geometry (perfect-mirror earth) the probe potential moves by 2.5e-4 at 50 Hz and its coupled imaginary part by +37 % (overhead) and +21 % (buried) at 1 kHz; v0.15.0 gave identical results for both lead types. Affected: TnNetworkGenerator worlds with measurement leads. Golden cases: gen_tn_measurement_overhead_leads (potentials up to 2.5e-4, currents up to 2.8e-4, lead end points). Test: tests/test_measurement.py::test_buried_lead_runs_at_its_depth, tests/test_measurement.py::test_overhead_lead_lies_above_ground.

Deprecated

  • English names replace the German identifiers and capitalised unit suffixes of the generator layer (10.69). Every old name keeps working, emits a DeprecationWarning naming the replacement, and is removed no earlier than 2027.5. Configurations written by v0.15.0 (JSON keys kvs, source_magnitude_A, star_kvs, resistivity, thickness_m, ...) still load.
old (v0.15.0) new
module groundfield.generators.ortsnetz_builder groundfield.generators.layout
OrtsnetzLayout LvNetworkLayout
KvsPlacement CabinetPlacement
KvsConfig CabinetConfig
StarKvsTopology, kind="star_kvs" StarCabinetTopology, kind="star_cabinet"
TnNetworkConfig.kvs TnNetworkConfig.cabinets
TnNetworkConfig.source_magnitude_A TnNetworkConfig.source_magnitude_a
CabinetConfig.quote_per_100_buildings CabinetConfig.count_per_100_buildings
RadialTrunkTopology.slots_per_kvs RadialTrunkTopology.slots_per_cabinet
RadialTrunkTopology.kvs_spacing_m RadialTrunkTopology.cabinet_spacing_m
RadialTrunkTopology.plan_feeder_kvs_positions() RadialTrunkTopology.plan_feeder_cabinet_positions()
LvNetworkLayout.add_kvs() LvNetworkLayout.add_cabinet()
LvNetworkLayout.kvs_placements LvNetworkLayout.cabinet_placements
from_osm(kvs_lat_lons=, kvs_xys=) from_osm(cabinet_lat_lons=, cabinet_xys=)
to_world(kvs_grounding=) to_world(cabinet_grounding=) (also on the new plan)
source_magnitude_A= of to_world, measured_grounding_impedance, verify_current_balance source_magnitude_a=
result keys positive_side_A, auxiliary_side_A, expected_*_A, abs_error_*_A, tolerance_A of verify_current_balance positive_side_a, auxiliary_side_a, expected_*_a, abs_error_*_a, tolerance_a
HomogeneousSoilSpec.resistivity HomogeneousSoilSpec.rho
SoilLayerSpec.resistivity, SoilLayerSpec.thickness_m SoilLayerSpec.rho, SoilLayerSpec.h

The module alias groundfield.generators.tn_ortsnetz keeps working as before. Test: tests/test_generator_naming.py.

Security

  • Bounded, validated Overpass requests (10.05): timeout_s was put into the query text unchecked (a string could inject Overpass QL); NaN or out-of-range coordinates and radii reached the server; the response was read into memory without limit; an HTTP-200 payload with a runtime-error remark was cached as an empty result; a writer killed mid-way left a truncated cache file that broke every later call. Now timeout_s must be an integer in [1, 900] s, coordinates finite WGS84 values and the radius at most 10 km; endpoints must use https (http only for localhost); the body is streamed and capped (max_response_bytes, default 64 MiB); error remarks and malformed payloads raise OverpassError and are not cached; cache files are written atomically and an unreadable one is fetched again with a warning; a non-default endpoint is part of the cache key (the default endpoint keeps the old key, existing caches stay valid); the query text of valid requests is unchanged. Test: tests/test_overpass_ingest.py (mocked transport; one real request behind the network marker).
  • MD5 on FIPS systems (10.07): the penetration-mask hash called hashlib.md5() without usedforsecurity=False and failed on FIPS builds of Python. The digest is unchanged, so stored masks stay valid. Test: tests/test_generator_reproducibility.py::test_mask_works_where_md5_is_blocked_for_security.

Stream eng1: Engines: floating clusters, cim, layer stacks, fem, benchmarks

Added

  • Engine benchmark suite B1–B13 (10.76, R2 §3.3): tests/benchmarks/ holds reference worlds with analytic or independently computed reference values (hemisphere, thin-wire Galerkin rod, closed-form thin ring, Tagg/Sunde series, mpmath three-layer kernel, floating-port two-port) and one explicit tolerance table per backend (tests/benchmarks/tolerances.py; python -m tests.benchmarks.tolerances prints it as Markdown for the validation page). Skipped by default; run with pytest tests/benchmarks --run-benchmark. The image-family cross-layer rod (B7) is a strict xfail until 10.15 lands.
  • FemReductionWarning (10.23): fem names every reason why its equivalent-hemisphere reduction does not model the world (several electrodes in a cluster, several clusters in a driven world, a layer interface between the electrode and its hemisphere), once per solve. Exported from groundfield.solver.fem. Test: tests/test_fem.py::test_fem_warns_when_electrode_and_hemisphere_straddle_an_interface.
  • compare_engines tolerance table (10.71): EngineComparison.rows (one ComparisonRow per quantity, frequency and real / imaginary part, with values, reference, deviation, tolerance and verdict), frequencies, impedances (complex values per engine and frequency), input_deviations; new keyword component_floor (default 1e-3). summary() prints the table. Test: tests/test_compare_engines.py::test_compare_engines_tolerance_table_is_explicit.
  • mom_sommerfeld convergence metadata (10.47): converged (bool, true only if every frequency converged), converged_per_frequency, n_unconverged_entries and, when the two-layer diagonal is the Tagg/Sunde series (every segment in the upper layer), n_terms_used. Test: tests/test_mom_sommerfeld.py::test_solve_reports_convergence_in_the_metadata.
  • ComplexImageFit.max_error (10.49): maximum error of the complex-image fit on the verification grid including λ = 0. Test: tests/test_cim.py::test_fit_converged_flag_bounds_the_maximum_error.

Changed

  • ⚠ mom, bem, mom_sommerfeld: source-free clusters float (10.29). A cluster without a source is now an unknown with zero net current (a floating equipotential) instead of being dropped and read back as the mean of the incident field. Numbers move for every world with a passive cluster in these backends: potentials read at a passive electrode by −59 % (rod through h₁ = 2 m in 1000/30 Ω·m: 3.548 → 1.440 Ω transfer impedance) to +1.5 % (100/1000 Ω·m), −0.4 % in homogeneous soil; the driven electrode's impedance by −0.009 % to −0.49 % because the floating neighbour now perturbs the field (R2 two-port worlds, 4 m apart). Passive networks joined by finite conductors carry their equalising current. Affected: probe and auxiliary electrodes, unbonded neighbours and passive conductor networks solved with the MoM family; the image family and the AP1 catalogue path are unaffected. Golden cases: none of the stored cases has a passive cluster in these backends (bit-identical); new case mom_two_port_passive_ring_two_layer.
  • ⚠ cim reports the length-weighted node potential (10.30), as image_2layer has since 0.15.0 (F10). Numbers move on electrodes with unequal segment lengths: −3.9 % (rod split unevenly at h₁ = 2 m: 71.060 → 68.262 Ω), −1.1 % (the F10 rod shape); uniform segments are unchanged. Golden cases: cim_rod_two_layer bit-identical; new case cim_grid_unequal_segments.
  • ⚠ Canonical layer stack (10.48). The layered backends (mom, bem, cim, mom_sommerfeld, and image_nlayer through as_layer_stack) merge adjacent layers of equal resistivity and drop zero-thickness layers before choosing a kernel: MultiLayerSoil([ρ, ρ, ρ]) is homogeneous and [ρ₁, ρ₂, ρ₂] is the two-layer soil it describes. Stacks that raised before now solve; mom accepts a MultiLayerSoil with at most two distinct layers; FieldResult.soil carries the canonical soil model (with the relative permittivity of the upper layer of each merged group), so potential() works for such stacks. Numbers move only for equal-resistivity declarations whose electrodes cross the declared interface (no longer split there): +0.07 % (mom, bem, mom_sommerfeld) and +0.42 % (cim) for a 3 m rod through h = 2 m in TwoLayerSoil(100, 100, 2). fem keeps the declared stack. Golden cases: none moved; new case mom_sommerfeld_duplicated_stack.
  • ⚠ fem: the truncation sphere no longer costs radial resolution (10.49). For a layer stack deeper than 1 m the radial line count grows with ln(r_far / a_eq), so the radial step ratio stays that of the homogeneous mesh. Layered fem results move up by +0.16 % (h₁ = 5 m), +0.41 % (30 m), +1.07 % (1 km) and +1.64 % (10 km) for a 1.5 m rod with ρ₂ = ρ₁ (from −0.16 % … −1.62 % to within ±0.005 % of the homogeneous value); homogeneous soil and stacks with Σh ≤ 1 m are unchanged. metadata["fem_mesh"][cluster]["n_radial"] reports the count used. Affected: every layered fem result. Golden cases: fem_rod_hom bit-identical; new case fem_rod_two_layer_deep.
  • fem is experimental (10.23). Module and solve_fem docstrings say what the equivalent-hemisphere reduction is and is not (no longer "the third independent cross-check" and "better than 5 %"); the registry flag follows with the backend registry.
  • compare_engines compares complex impedances at every frequency (10.71): cluster impedances and the input impedance of every current source, real and imaginary part separately, at all frequencies (up to 0.15.0: Re Z of the clusters at the first frequency). Engines with different frequency lists raise ValueError; a value that is non-finite for some engines only is a failure. Comparisons that passed before may now be reported inconsistent; deviations per cluster is the worst over all frequencies and both parts.
  • metadata["solver"] is "point_matching" for mom, bem and mom_sommerfeld (10.31) (was "galerkin" / "collocation" / "galerkin" for one and the same scheme).

Fixed

  • Transfer impedances of the MoM family are reciprocal (10.29). Z_AB and Z_BA from two solves differed by 4.0e-3 (homogeneous) to 1.46 (rod through the interface); now below 1e-8 (cross-layer quadrature) and 7e-16 (closed form). Test: tests/test_mom_family.py::test_two_port_transfer_impedance_is_reciprocal.
  • cim is bit-identical to image_2layer and reciprocal (10.30), as its reduces_to metadata and the 0.15.0 notes claimed. Test: tests/test_cim.py::test_cim_is_bit_identical_to_image_2layer_for_unequal_segments.
  • Physically two-layer or homogeneous MultiLayerSoil stacks no longer raise (10.48) in cim, bem, mom, mom_sommerfeld and image_nlayer. Test: tests/test_layer_stack.py::test_duplicated_layer_stack_is_solved_like_two_layers.
  • mom_sommerfeld: a capped oscillation budget is no longer silent (10.47). When max_osc_panels binds, every rung of the refinement ladder shares the capped J₀ grid, so two rungs could agree while the absolute floor epsabs dominated: kernels 5 km apart over a 5 cm layer were up to 3.1e-3 wrong without a SommerfeldConvergenceWarning (7 of 1050 stress points). A binding budget now counts as non-convergence; the largest silent error on the stress grid is 2.0e-10. The truncated Tagg/Sunde series of the two-layer diagonal warns like in mom. Test: tests/test_mom_sommerfeld.py::test_kernel_warns_or_converges_when_the_oscillation_budget_binds.
  • fit_complex_images no longer reports converged=True for a fit that misses Γ₁ by more than rms_tol (10.49). The flag was RMS-gated: 26 of 300 random 3–6-layer stacks passed with a maximum error of up to 3.5e-3 between the fitting samples; the maximum error on the verification grid including λ = 0 is now part of the gate (0 of 300 silent). No solver path uses the fit. Test: tests/test_cim.py::test_fit_converged_flag_bounds_the_maximum_error.
  • compare_engines sees the reactance, every frequency and non-finite results (10.71). Perfect-mirror and Sommerfeld earth return (input reactance 0.600 vs 0.376 Ω at 1 kHz) were reported consistent. Test: tests/test_compare_engines.py::test_compare_engines_sees_the_reactance_at_every_frequency.
  • fem warns where its reduction is not a valid cross-check (10.23): +1092 % for a 3 m rod through h₁ = 2 m, −92 % for a 10 m ring above it, −35 % for a ring with three bonded rods, transfer impedance 0 between clusters — all silent before. Test: tests/test_fem.py::test_fem_warns_for_a_multi_electrode_cluster.
  • fem truncation (10.49): see Changed. Test: tests/test_fem.py::test_fem_deep_interface_does_not_degrade_the_resolution.

Documentation

  • mom, bem and mom_sommerfeld are documented as one point-matching scheme (10.31): pulse basis, delta test at the segment midpoints, point-source near field. mom is not Galerkin and its bordered system is not symmetric; it lies 1.0 % (ds = 0.5 m) to 1.7 % (ds = 0.0625 m) below the exact thin-wire Galerkin solution of a 3 m rod and drifts by −0.96 % over that ladder, while image is closer at every ds; bem assembles the identical matrix; mom_sommerfeld shares the discretisation and is a kernel reference, not an independent scheme. The stale advice to lower lambda_max_factor on the delegated cross-layer path is removed (factors 30 … 20 000 change that kernel by ≤ 1.3e-8). No physics change. Test: tests/test_mom_family.py::test_mom_family_reports_one_point_matching_scheme.

Removed

  • The unused private helpers cylindrical_radius and _split_layer_thicknesses of groundfield.solver._layered (10.81).

Stream coup1: Coupling: image conventions, Sommerfeld, Pollaczek, Carson

Added

  • Image conventions for the inductive stack (10.20 preparation, F32): build_inductance_matrix(..., image="none" | "additive" | "antiparallel") (the legacy use_image=True/False maps to "additive"/"none"), and the same image= argument on build_carson_correction_matrix, build_sommerfeld_correction_matrix and the Sommerfeld pair integrals: a correction states which image the inductance matrix it is added to carries, so j·ω·L(image) + ΔZ(image) is the same physical matrix for every convention. Carson's correction is documented as defined against the anti-parallel image; the defaults reproduce the numbers of 0.15.0 for carson_series and perfect_mirror. The solver switches carson_series to the anti-parallel baseline in a later step of this release. Tests: tests/test_sommerfeld_accuracy.py::test_total_impedance_does_not_depend_on_the_image_convention, tests/test_sommerfeld_accuracy.py::test_carson_on_the_antiparallel_baseline_matches_carson.
  • Multi-frequency earth-return builders (10.60, 10.63): build_sommerfeld_correction_matrices(seg_endpoints, radii, omegas=..., earth=...) and build_carson_correction_matrices(...) return all frequencies at once; geometry, λ grid and the Bessel table are built once per segment pair. Each frequency is bit-identical to the single-frequency builder. On the inductive PEN branches of a 2-house street network (34 branches, 11 frequencies) the Sommerfeld assembly takes 1.5 s CPU against 7.6 s for eleven single-frequency calls and 31.8 s in 0.15.0. Carson's P, Q are memoised on (a, θ) (bit-identical; 9130 → 2321 evaluations and 3.9× less CPU time on a 10-house network). Tests: tests/test_sommerfeld_accuracy.py::test_multifrequency_matrices_are_bit_identical, tests/test_carson_pq.py::test_multifrequency_carson_matrices_are_bit_identical_and_cached.
  • Exact touching segment pairs, opt-in (10.46): touching="exact" on neumann_mutual and build_inductance_matrix uses Grover's closed forms for segments that share an end point (chain neighbours, bends) or lie on one axis; the 16×16 Gauss–Legendre rule is −0.3 % … +0.8 % off for such pairs, and a straight wire split into n segments now keeps the self inductance of the unsplit wire exactly. The default stays "quadrature" until the solver switches. Test: tests/test_neumann_touching.py::test_chain_sum_is_refinement_invariant.
  • Per-segment internal inductance (10.46): include_internal of build_inductance_matrix accepts a boolean array. The package-wide convention (DC internal inductance μ₀/8π per metre included; compare with references at GMR = a·e^(−1/4)) is documented in groundfield.coupling.inductance, the Carson and Pollaczek references. Test: tests/test_coupling_conventions.py::test_internal_inductance_convention_matches_references.
  • Opt-in skin effect (10.37): Conductor(resistance_model="skin") with Conductor.internal_impedance_per_length(f) and Conductor.skin_correction_per_length(f) (the correction relative to the DC convention), based on the new groundfield.conductors.solid_round_internal_impedance (exact Bessel solution): 150 mm² Al has R_ac/R_dc = 1.231 at 550 Hz and 1.550 at 1 kHz, internal inductance 0.740× at 1 kHz. The default "dc" changes nothing; the solver uses the correction in a later step of this release. Test: tests/test_skin_effect.py::test_150mm2_aluminium_resistance_ratio.
  • Close, interpenetrating and crossing wires (10.44): groundfield.conductors.find_close_wires(endpoints, radii, names, ...), find_close_conductors(conductors, ...) and segment_distance report wire pairs of different owners closer than rel_threshold·(a_i + a_j), classified as crossing / interpenetrating / close (junctions at shared end points are skipped by default). Test: tests/test_conductor_proximity.py::test_parallel_rods.
  • LayeredEarth.interface_depths and LayeredEarth.layer_of(depth).

Changed

  • ⚠ references.pollaczek is exact for two layers (10.45): the self and mutual impedances use the exact buried-conductor amplitude (lower-interface term included) and the K0(γ·GMR) head instead of ln(2h/GMR). R′ moves by +0.15 % (1 m) and +1.0 % (3 m) at 30 Ω·m, 1 kHz (homogeneous), by up to +0.5 % in band near a layer interface, and by +40 % at 1 MHz (Tsiamitros Case V); X′ by less than 0.02 % in band. Conductors below the first interface and pairs in different layers are now supported exactly. Affects users of pollaczek_self_impedance, pollaczek_mutual_impedance, loop_impedance_conductor_earth (the AP1 catalogue builds its own z′ table from these). Golden cases: none.
  • Carson P, Q (10.46): the asymptote is used only for a > 15 (was 5), where it is accurate to 1e-7; moves carson_series only for pairs with a > 5 (e.g. more than 560 m apart at 1 kHz in 100 Ω·m). Golden cases: none.

Fixed

  • ⚠ Sommerfeld λ grid resolves distant pairs (10.36): the logarithmic region ended at max(p_skin, 1/z) whatever the pair distance, so J0 was unresolved there, and the linear region was capped at 4096 panels without a check: pair entries were off by −24 % (Re, 200 m) and +274 % (Re, 400 m), +2.35 % (Im, 400 m). The grid now follows the F14 policy of layered_green (log region below π/(4ρ_max), 16 nodes per J0 period, graded panels at the skin and layer scales) and raises SommerfeldResolutionWarning instead of truncating; entries agree with an independent quadrature to 1.2e-5 (R′ part) and 2.7e-6 (X′ part) for pairs 50–400 m apart. Golden cases: cond_galvanic_neumann_sommerfeld, defaults_mixed_cluster_inductive (≤ 1.8e-9), cond_isolated_pen_sommerfeld_two_layer (≤ 1.9e-5). Test: tests/test_sommerfeld_accuracy.py::test_distant_pair_entry_matches_independent_quadrature.
  • ⚠ Sommerfeld kernel exact for n ≥ 3 layers and below the first interface (10.35): the buried kernel used the single air-image form outside the two-layer/layer-1 case; a three-layer earth with ρ₂ = ρ₃ gave +17 … +25 % X′ against the identical two-layer earth. The kernel now uses generalised reflection coefficients (any number of layers, any layer) and the transmitted amplitude for pairs in different media. Affects sommerfeld worlds on MultiLayerSoil and conductors deeper than h_1. Golden cases: none. Tests: tests/test_sommerfeld_accuracy.py::test_three_layer_duplicate_equals_two_layer, tests/test_sommerfeld_accuracy.py::test_conductor_below_first_interface.
  • ⚠ earth_return_correction_layered had the wrong sign (10.46, F50): the reflected term was +8.739e-3 + 6.484e-3j instead of −6.346e-3 − 4.580e-3j (earth 100/10 Ω·m, h₁ = 3 m, 1 kHz, z = z′ = 0.6 m); it now uses the exact layered kernel. Test: tests/test_sommerfeld_accuracy.py::test_layered_point_kernel_has_the_exact_sign.
  • ⚠ Exact removal of the additive image in the Sommerfeld correction (10.46): the image was removed as −1/R′ integrated by the 16×16 outer rule with the direct orientation, so vertical segments kept twice the image in the σ → 0 limit and 50 m segments at 0.7 m lost 2 % of it. The correction now subtracts the very image block the inductance matrix added. Golden cases: see the λ-grid entry. Test: tests/test_sommerfeld_accuracy.py::test_transparent_earth_cancels_the_additive_mirror.
  • Segments crossing the soil surface (10.46, F52): an inductive segment whose end points lie on both sides of z = 0 was dispatched by its midpoint (World.solve solved silently) or rejected as "lying in the soil-surface plane". With an image convention it now raises a ValueError that says the segment crosses the surface (its image intersects it); with image="none" the Sommerfeld pair integrals split such segments at the surface and at layer interfaces. Tests: tests/test_sommerfeld_accuracy.py::test_surface_crossing_segment_is_rejected_with_the_right_message, tests/test_sommerfeld_accuracy.py::test_world_solve_rejects_surface_crossing_inductive_conductor.
  • Carson's Q asymptote had the wrong sign of its a⁻⁷ term (10.46): +45, not −45; together with the boundary move the large-a regime is continuous to 1e-7 (it jumped by up to 9.3e-4 at a = 5). Tests: tests/test_carson_pq.py::test_q_asymptote_a7_term_has_positive_sign, tests/test_carson_pq.py::test_large_a_regime_is_continuous.
  • Conductor input validation (10.43, 10.67): cross_section <= 0 or non-finite, non-finite resistivity / wire_radius / end points raise a ValueError naming the parameter (they failed late with ZeroDivisionError or LinAlgError, or gave an active element); a cross section above 1e-2 m² warns with CrossSectionUnitWarning (cross_section=50 meant as mm² was a silent 6.7 nΩ short); an ideal conductor with discretize_segment_length raises (it was LinAlgError: Singular matrix at solve time). Tests: tests/test_conductor_validation.py::test_nonpositive_or_nonfinite_cross_section_raises, tests/test_conductor_validation.py::test_cross_section_in_mm2_warns, tests/test_conductor_validation.py::test_ideal_distributed_conductor_raises_with_parameter_name.
  • Documentation in the coupling package: English prose in coupling/layered_green.py (10.95); the Carson layered-soil warning points to earth_inductive_model="sommerfeld" (it named backend='mom_sommerfeld'); the internal-inductance statement of references.earth_return ("external inductance only") is corrected. Test: tests/test_coupling_conventions.py::test_layered_green_prose_is_english.

Stream core2a: Two-terminal sources, junctions and diagnostics

Added

  • Junction nodes (10.38, prerequisite of 10.17): groundfield.api.create_junction(world, position=..., name=None) creates a leakage-free network node (groundfield.geometry.junction.Junction, World.junctions, World.add_junction / get_junction). Conductors start or end at junctions (create_conductor accepts junctions and their names) and sources attach to or return at them; a junction has no soil contact, takes part in Kirchhoff's current law and reports its potential per frequency in FieldResult.metadata["junction_potentials"]. Electrodes and junctions share one node namespace. A junction subnetwork without soil contact (no path to an electrode or a galvanic conductor) is rejected before the solve. Measurement leads that end on junctions at the instrument leave the soil problem exactly unchanged (fall-of-potential Z_meas equal to the lead-free value to 5.4e-16), where a probe lead ending on the station short-circuits the voltmeter (0.46 % of the true value); a junction leaks nothing where a 5 cm joint rod leaked 0.35 % of the test current in the test world. Worlds without junctions serialise exactly as before. Supported by the image family (BackendCapabilities.junctions); other backends reject such worlds with BackendCapabilityError. Tests: tests/test_junction_nodes.py.
  • World.check() (10.66): validates source terminals and conductor ends (with the closest names), the excitation, voltage sources and short-circuited two-terminal sources; called by every solve. Test: tests/test_source_validation.py.
  • Aggregated diagnostics (10.70): groundfield.diagnostics.diagnose(world, engine=None, *, result=None, proximity=True) returns a DiagnosticsReport of Diagnostic findings (category, severity, subjects, message, data) for thin wires, resolution, segment budget, close or interpenetrating leakage wires (groundfield.conductors.find_close_wires, 10.44), inert settings (conductors not attached at both ends, the deprecated shell registry, non-default boundary conditions or permittivity) and, with a result, series truncation. str() prints one line per cause, .warn() emits one DiagnosticsWarning. Close wires are a warning with the point kernel (two bonded 3 m rods 2 mm apart solve to 5.7 times the one-rod impedance) and information with the exact line kernel (0.998 times). Test: tests/test_diagnostics_report.py.
  • diagnostics.check_segment_budget and ResourceLimitError (10.06): the hard segment limit of the solver pipeline (see Fixed).

Changed

  • ⚠ Source.return_to is honoured by the image family (10.16, F01/F30). image, image_2layer and image_nlayer inject +I at attached_to and -I at return_to through one shared injection step; the leakage currents of a world of two-terminal sources sum to zero and input_impedance() is (φ_a − φ_r)/I. Up to 0.15.0 the auxiliary electrode of a simulated fall-of-potential measurement carried 0 A and the station potential did not depend on its distance (13.107017 V for d_aux = 20 … 1600 m in the test world); now 12.310 V at 20 m rising to 13.097 V at 1600 m, and the probe at 61.8 % reads the remote impedance to −1.6e-3 (20 m), −3.5e-6 (200 m), as Tagg's rule says (0.15.0: −9.9 % and −0.98 %). Who is affected: every world whose sources set return_to — the measurement worlds of TnNetworkGenerator and LvNetworkLayout. The generators still wire the feed lead from the station straight to the auxiliary electrode, so that lead now closes the loop metallically (station potential 1.5008 V → 4.15e-3 V in the golden case); they are re-wired through junctions in the generator work (10.17). LvNetworkLayout still adds its 180° counter-source until then, which now counts the return current twice; the solve warns about such a counter-source. Golden case: gen_tn_measurement_overhead_leads.
  • ⚠ Source-free clusters float in the image family (10.29, image half). A bonded group of passive electrodes and a passive network joined by finite conductors now enter the nodal system with zero net impressed current instead of being dropped and read back as the incident field: one potential per cluster, equalising currents, and members of an isolated floating cluster report currents that sum to exactly zero (cluster impedance nan). Passive ring + rod bonded pair beside a driven rod: 2.5735 V / 1.8055 V and 0 A became one 2.4119 V with ±14.3 mA (mom: 2.4189 V, ±13.1 mA). A lone passive electrode is unchanged (exactly equivalent under the uniform-current ansatz), so worlds without bonded passive groups or passive networks are bit-identical. Who is affected: probe and auxiliary electrode groups, unbonded neighbours with several electrodes, passive measurement leads. Golden case: cond_coupled_leads_open_circuit (the grounded measurement lead beside the source lead: φ(m1) +42.5 %, driven side −0.89 % / −3.8 %).
  • One warning per cause instead of per electrode (10.70): check_segment_resolution aggregates its findings (docs example 07: 81 resolution warnings became 9, one per solve); the return_to capability warning disappears for the image family.
  • expected_segments follows the solver's discretisation (10.79), including wires split at soil-layer interfaces (a 3 m rod across h₁ = 1.3 m: 7 segments, the 0.15.0 prediction said 6). Test: tests/test_diagnostics_report.py::test_expected_segments_is_exact_for_rods_split_at_the_interface.

Fixed

  • Invalid source references solved silently (10.66). A misspelled attached_to / return_to, a source on a conductor (documented as allowed, injected nothing), a source returning to its own node, a world without a current source, a source of magnitude 0, and a conductor end naming no node (the conductor dropped out of the network) now raise — at create_source / World.add_source / World.add_conductor, or when an edited or loaded world is solved — with the closest names. magnitude and phase_deg must be finite, also when assigned later. Tests: tests/test_source_validation.py.
  • VoltageSource solved to all-zero potentials (10.51). Solving a world with a voltage source raised NotImplementedError in the release preparation, naming the alternative (a 1 A current source scaled by U / Z_in); voltage sources are solved since 2026.11 (stream w2src, audit W2A-11). Test: tests/test_source_validation.py::test_voltage_source_solves_and_fixes_the_feeding_potential.
  • HARD_LIMIT only warned (10.06). A world whose predicted segment count exceeds groundfield.diagnostics.HARD_LIMIT (20 000, read at solve time) is rejected with ResourceLimitError before anything of the problem size is allocated, also in solve_mutual_*: a 5 m ring entered in millimetres (62 832 segments) fails after 0.06 s with a 0.67 MiB allocation peak; the wave-1 code solved the full problem (173 s, 140 MiB peak on the review machine) and returned 0.0096 Ω. Test: tests/test_diagnostics_report.py::test_world_beyond_the_hard_limit_is_rejected_before_any_allocation.
  • Polyline and star electrodes skipped by the resolution check (F53, F54). Listed as fixed in 0.15.0, but diagnostics.py was unchanged since 0.13.0; every electrode kind is now checked through Electrode.min_feature_length(). Test: tests/test_diagnostics_report.py::test_resolution_check_covers_star_and_polyline.
  • Close wires went unreported (10.44, diagnostics part): see diagnose above. Test: tests/test_diagnostics_report.py::test_close_and_interpenetrating_wires_are_reported.

Deprecated

  • World.concrete_shell_corrections (the lumped ADR-0012 V1 registry, 10.12–10.14): the solver consumes concrete shells only as the per-length coefficient concrete_shell_coefficient_ohm_m of the electrodes and never read this registry (nor did solve_mutual_*). Solving a world with entries emits a DeprecationWarning naming the coefficient; the field still loads from JSON and will be removed no earlier than 2027.5. Test: tests/test_concrete_shell_registry.py.

Stream core2b: Default line kernel, cross-layer electrodes, concrete shells, mutual matrix

Added

  • Concrete shell on every electrode kind (10.12–10.14): rods, rings, meshes and grid meshes carry concrete_shell_coefficient_ohm_m like strips, polylines and stars. It is the one mechanism through which the solver sees a concrete encasement (ADR-0012): every segment of length Δs adds C/Δs to its reaction-matrix diagonal, in the image family and in solve_mutual_matrix / solve_mutual_field; with the uniform current per electrode this is exactly the lumped shell resistance R = C/L in series with the electrode. Conversion helpers in groundfield.geometry.electrodes: concrete_shell_coefficient(rho_c, wire_radius, thickness) (C = ρ_c/(2π)·ln((r_a + t)/r_a), 38.16 Ω·m for 100 Ω·m and 5 cm around a 5 mm wire), shell_coefficient_from_resistance(electrode, R) (C = R·L) and shell_resistance_from_coefficient(electrode, C=None) (R = C/L), which the generators use for concrete_model="lumped". Rods, rings and meshes without a shell serialise exactly as before. Tests: tests/test_concrete_shell_coefficient.py.
  • solve_mutual_matrix(..., offdiag="galerkin") (10.34): the off-diagonal entry Z_ij is the reaction T_iᵀ(K + S)T_j of the two leakage distributions — the potential of cluster i under excitation j, reciprocal to round-off without symmetrisation, and the matrix with which (Y_L + Z_G⁻¹)u = i reproduces the solve of the clusters joined by branches. probe_points is optional; offdiag=None (default) selects "galerkin" without probe points and "probe" with them, so existing calls keep their numbers apart from the diagonal (see Changed). On an AP1-like site (station ring + three rods, 12 polygon foundations, ds = 2 m, five soils) the galerkin matrix reproduces a network solve with PEN-like branches to ≤ 2e-5, while the symmetrised probe matrix misses the input impedance by −0.15 … −0.88 % and single entries by up to 46 %; for Z_G as a network element offdiag="galerkin" is recommended. Tests: tests/test_mutual_matrix.py::test_galerkin_offdiagonal_is_reciprocal, ::test_galerkin_matrix_reproduces_the_joined_network, ::test_offdiag_selection_and_validation.

Changed

  • ⚠ Exact line-source kernel is the default of the image family (10.28): Engine.kernel defaults to None, the backend's preferred kernel: "line" for image, image_2layer and image_nlayer (also used by FieldResult.potential and solve_mutual_*), the backend's own kernel elsewhere; metadata["kernel"] records the kernel that ran and kernel="point" reproduces releases up to 0.15.0. The request is carried in the value, so engines rebuilt from JSON, with_frequencies or a provenance block run like the original. Numbers move for every default solve of the image family: rod 3 m +0.60 % (surface potential up to 1.9 %), two-layer ring +1.23 %, two rods joined by a galvanic conductor of 5 m segments: currents 10.9 %, cluster impedance 8.4 %. Cost: a 16-house solve (N = 1920) takes 2.7 times as long as with the point kernel with numba installed and 5.7 times without. In two-layer soil a straight 10 m strip stays within 0.05 % of its exact uniform-current resistance for ds = 0.125–2 m (point kernel: up to 22 %). Golden cases: defaults_rod_hom, defaults_two_layer_ring_auto, defaults_mixed_cluster_inductive.
  • ⚠ Electrodes through a soil-layer interface (10.15, F02): in image_2layer and solve_mutual_* an electrode that crosses h₁ (where the resistivity changes) has one uniform-current owner per layer, all in its cluster, so the current density may differ above and below the interface. A 12 m rod through h₁ = 5 m now equals the manual split into two bonded rods and lies +0.11 … +0.31 % from mom with the point kernel (+0.7 … +1.3 % with the line kernel, its offset from point-matching methods; 0.15.0: +566 % in 1000/30 Ω·m, +148 % in 1000/100, +123 % in 100/1000). TwoLayerSoil(ρ, ρ, h) stays bit-identical to the homogeneous backend. Who is affected: rods through h₁ — not the AP1 station rods (4 m from 0.6 m, h₁ ≥ 5 m). Golden cases: img2_rod_crosslayer (−46.5 %), line_img2_rod_crosslayer (−48.2 %), mutual_three_rods_crosslayer.
  • ⚠ Interface slivers and segment counts (10.32): an interface cut that would leave a wire part shorter than the wire diameter (geometry.electrodes.SLIVER_RADII = 2 radii) is dropped; the point kernel takes the Galerkin self term for segments shorter than 2.99 wire radii (identical above); segment counts ignore floating-point noise (ceil(L/ds − 1e-9)): a star arm of 3.000000000000001 m is cut into 6, not 7 segments at ds = 0.5 m (≤ 6.9e-5 point kernel, ≤ 8.3e-8 line kernel). Golden cases: img_mixed_cluster_hom, line_img_mixed_cluster_hom.
  • ⚠ Post-solve series controls follow the engine (10.25): FieldResult.potential, solve_mutual_matrix and solve_mutual_field sum the Tagg/Sunde series with the controls recorded with the solve (metadata["series"], the engine defaults for results without the record) instead of a hard-coded 100 terms / 1e-6, and warn with SeriesTruncationWarning when the series is truncated. For K = −0.94 and image_max_terms=2000 the potential 100 m from a ring moved by 0.8 %. The backend entry points solve_image_2layer / solve_image_nlayer take the engine's controls instead of private defaults 100 / 200 (10.74). Golden cases: none (the cases use the default 300 terms).
  • ⚠ solve_mutual_matrix diagonal (10.26): Z[j, j] is the cluster impedance reduced like FieldResult.cluster_impedance — length-weighted over every member and every layer owner — instead of the unweighted mean over the alphabetically first member; equal to the per-excitation solve to ≤ 2.2e-16. 0.15.0 deviated by +0.150 % for an L-shaped footprint at ds = 2 m and by −3.8 / −9.1 % for a rod split at h₁. AP1-like site (ds = 2 m): house foundations up to 0.10 %, station 0.000 %. Golden cases: mutual_* (round-off; mutual_three_rods_crosslayer see 10.15).
  • solve_mutual_matrix / solve_mutual_field check the backend (10.34): the engine's backend is resolved and checked like in Engine.solve (aliases, capability check, kernel); a backend outside the image family raises BackendCapabilityError (a ValueError) instead of returning image numbers (an 8-arm star: 7.854 Ω returned for a mom engine whose own solve gives 7.128 Ω). Test: tests/test_mutual_matrix.py::test_non_image_backend_is_rejected.
  • ⚠ solve_mutual_matrix / solve_mutual_field: the other clusters float (10.29): each excitation is solved with the source-free clusters floating (zero net current, equalising currents in bonded groups and between the layer owners of a rod through h₁), as Engine.solve does since 10.29; the galerkin off-diagonal is then the exact potential of the passive cluster. AP1-like site: diagonal 3.3e-5, galerkin off-diagonal up to 0.09 %. Golden case: mutual_foundations_distributed_concrete (Z_G 5.2e-4, R 1.6 %).
  • Engine.solve validates the world (10.66): it runs World.check(require_source=False) for every backend and entry point (dangling references, short-circuited sources, zero or non-finite magnitudes); a world without a source stays solvable through Engine.solve (all results zero), as before.
  • Cross-layer solves report no image series (10.50, F43): a solve on the ADR-0007 path (an electrode reaches h₁) no longer reports the term count or the truncation of a series it never evaluates; metadata gains series_used and series. Test: tests/test_series_controls.py::test_cross_layer_solve_reports_no_series.

Fixed

  • Degenerate electrode geometry (10.67): zero-length strips, non-positive mesh or grid extents, non-finite coordinates or lengths and dimensions not longer than the wire radius (typically a radius typed in mm) are rejected when the electrode is built; up to 0.15.0 they failed in the solver as a thin-wire violation, an OverflowError, or solved to Z = nan. Test: tests/test_electrode_validation.py.
  • Reciprocity of the line kernel across the layer interface (10.28): the cross-layer reaction matrix scaled the line corrections of the direct and surface-image terms with the source-layer resistivity while the layered correction kept the compensating terms in point form: 3.8 % asymmetric, and a two-port of a rod through h₁ and a ring non-reciprocal by 1.1–4.7 % (point kernel: 1e-8). Pairs in different layers now carry the transmitted resistivity 2ρ₁ρ₂/(ρ₁ + ρ₂), and the near-singular interface image of the layered correction is a Galerkin integral: symmetric to ~1e-8, and a rod through h₁ changes by less than 0.01 % per halving of ds (was up to 0.22 %). The interface image matters most for horizontal wires just below h₁: a ring (r = 3 m) 5 cm below the interface of 100 over 1000 Ω·m now gives 55.6–55.7 Ω at every ds from 0.5 to 0.025 m; the point kernel (and mom, and the line kernel before) gave 29.7 Ω at ds = 0.5 m (−46 %), converging to 54.7 Ω only at ds = 0.025 m. Keep ds well below 2|z − h₁| with kernel="point". Tests: tests/test_reciprocity.py, tests/test_cross_layer_line_kernel.py.
  • image_2layer with a layer stack (10.48): a MultiLayerSoil with two distinct layers raised a bare TypeError after passing the capability check; it now solves its canonical two-layer form, three distinct layers raise BackendCapabilityError. Test: tests/test_layer_stack_dispatch.py.
  • Interface slivers (10.32): a rod whose tip lay 1 mm below h₁ raised a ValueError, one 9 mm below acted as a short in mom (196.6 → 144.2 → 166.8 Ω for tips at 4.99 / 5.009 / 5.02 m). Test: tests/test_interface_slivers.py.
  • Junction terminals in FieldResult.input_impedance (10.38): a source attached to or returning at a junction reads the junction potential. Test: tests/test_junction_nodes.py::test_input_impedance_of_a_source_on_a_junction.
  • Line-kernel cost with one long segment (10.28): the near-pair search used the longest segment of the whole set as radius for every observer; one conductor discretised at 50 m turned a 16-house line solve from 0.8 s into 29 s and 1.7 GiB. Each segment now searches with its own radius (identical results); the reaction corrections of 3000 short plus three 35 m segments peak below 40 MiB (940.9 MiB before). Test: tests/test_line_kernel_near_pairs.py.
  • Two-layer mom assembled its series matrix twice per solve: the matrix is kept from the reaction-matrix assembly (bit-identical; 20 × 20 m grid, N = 400: 0.294 s → 0.154 s).

Stream eng2: Shared point-matching pipeline, Sommerfeld tabulation, fem guards

Added

  • mom_sommerfeld kernel tabulation report (10.61): metadata["kernel_tabulation"] (enabled, groups_tabulated, groups_pointwise, table_evaluations, max_check_error) and the keyword solve_mom_sommerfeld(..., tabulate=True); through the engine as options={"mom_sommerfeld": {"tabulate": False}} once the registry entry MomSommerfeldOptions.tabulate is in place. converged and converged_per_frequency (10.47) are kept. Test: tests/test_mom_sommerfeld.py::test_solve_reports_the_kernel_tabulation.
  • Benchmarks B12 and B13 (10.76, R2 §3.3): B12 checks the depth-group table of mom_sommerfeld against the pointwise quadrature on a 40 m grid in 1000/30/200 Ω·m (bound 1e-6; measured 0 at ds = 2.5 m, 6.9e-9 for single entries and 1.5e-10 for the grid impedance at ds = 1.25 m). B13 compares the per-metre series impedance of an isolated line (difference of a 1600 m and an 800 m line at 1 kHz, which cancels the end effects) with the Pollaczek conductor–earth loop impedance (reactance bound 5e-3, measured 4.1e-6; resistance bound 2e-2, measured −1.04 %). B7 keeps the strict xfail of image_2layer until 10.15 and records that fem raises. python -m tests.benchmarks.tolerances prints the table.
  • compare_engines names engines that ran the same computation (10.76): a deprecated name and its replacement with identical settings (cim and image_2layer, bem and mom) get a note that their agreement is not an independent cross-check. Test: tests/test_engine_aliases.py::test_compare_engines_notes_that_an_alias_is_no_independent_check.

Changed

  • mom, mom_sommerfeld and bem run the shared solve pipeline (10.75, 10.59). Discretisation, injection, topology and branch assembly are the steps of groundfield.solver._pipeline; the family keeps one shared point-matching solve and read-back, each backend contributes only its Green's function, and the reaction matrix is assembled directly instead of as the product of the kernel with the identity. The numbers are unchanged: 41 of 41 stored golden cases are bit-identical to the wave-2 base, and so are the numeric fields of 47 further results except bem (≤ 3.5e-16, it now runs mom) and the tabulated three-layer case of 10.61 (1.1e-9). The direct assembly makes mom_sommerfeld on two-layer soil faster (40 m grid, ds = 2.5 m: 15.2 → 0.41 s).
  • ⚠ mom and mom_sommerfeld honour Source.return_to and junction nodes (10.75 with 10.16 / 10.38). Because they now use the shared injection and topology steps, the return terminal of a two-terminal source draws the current back through its electrode (0.15.0: ignored, the current returned through remote earth), and metadata["junction_potentials"] reports junction nodes as the image family does. Numbers change for every world with a return_to source solved with these backends; no stored golden case contains one. Needs the registry flags two_terminal_sources and junctions for both backends. Tests: tests/test_point_matching_pipeline.py::test_mom_family_honours_return_to, tests/test_point_matching_pipeline.py::test_mom_family_reports_the_junction_potential.
  • ⚠ mom_sommerfeld tabulates the reflected kernel for n ≥ 3 layers (10.61). Segment pairs of one depth class in the top layer use a cubic spline in ln s (64 nodes per decade) instead of one quadrature per pair; eight midpoints per table are checked against the quadrature (tolerance 1e-7 of |G|, one refinement), and a group whose check fails or whose nodes do not converge falls back to the quadrature with the same convergence report. Every other pair is evaluated once per distinct (s, |Δz|, z + z') instead of once per pair, bit-identically. Results move where a table is used, by ≤ 1.1e-9 relative for the impedances measured and ≤ 6.9e-9 for single matrix entries (40 m grid at ds = 1.25 m: 4.8703316096 → 4.8703316089 Ω). Three-layer 40 m grid: 19.0 → 0.25 s (ds = 2.5 m, deduplication only, bit-identical) and 66.6 → 0.30 s (ds = 1.25 m, tabulated); a village of eleven rings at irregular positions (N = 273) takes 1.25 s instead of 34.1 s with the deduplication alone (impedance 1.8e-11 apart). Golden cases: none of the stored ones moves; new case mom_sommerfeld_three_layer_grid_tabulated. Test: tests/test_mom_sommerfeld.py::test_tabulated_reaction_matrix_is_within_1e_6_of_the_quadrature.
  • ⚠ fem raises when an electrode reaches a layer its hemisphere does not (10.23). An electrode below a layer interface that lies above the equivalent-hemisphere radius (a rod through or below the top layer) now raises BackendCapabilityError (a ValueError and NotImplementedError) before meshing. 0.15.0 returned +633 … +3138 % over a conductive lower layer (1000/30 Ω·m) and −10 … −85 % over a resistive one silently. Affected: rods in layered soil solved with fem; golden cases: none. Test: tests/test_fem.py::test_fem_rejects_an_electrode_below_its_hemisphere.
  • The mom family shares the depth advisories of the image family (10.75): ShallowSegmentWarning for segments long against their burial depth.

Fixed

  • mom, mom_sommerfeld, bem solved a segment that crosses the soil surface as if it were buried (10.75): a 1 m rod from z = −0.1 m gave 94.27 Ω; the shared depth guard now raises as it has for image since 0.15.0. Test: tests/test_point_matching_pipeline.py::test_mom_family_rejects_a_segment_partly_above_the_surface.
  • FemReductionWarning missed interfaces above the electrode (10.23, audit F01): the hemisphere spans the soil from the surface, but only interfaces between the electrode and the hemisphere radius were checked; a 10 m strip and a ring r = 5 m at 0.8 m below h₁ = 0.5 m (30/1000 Ω·m) came out −70 % and −47 % against mom without a warning. Every interface above the deeper of the electrode and its hemisphere is now reported, and so is an interface below both but within the electrode's horizontal half-extent (ring r = 10 m over h₁ = 5 m in 1000/30 Ω·m: −46 %, silent before). Where no rule applies, rings and strips measured in 1000/30, 100/1000 and 100/400 Ω·m stay within −7.4 … +4.3 % of mom. Tests: tests/test_fem.py::test_fem_warns_when_the_electrode_lies_below_a_thin_top_layer, tests/test_fem.py::test_fem_warns_when_an_interface_lies_within_the_electrode_extent.
  • compare_engines reported 34.3 Ω against 0 Ω as consistent (10.71, audit F03): a quantity was skipped as "undefined for every engine" as soon as one engine returned zero. Only a quantity that is zero for every engine is skipped now; a zero for some engines fails with an infinite deviation and a note. Test: tests/test_compare_engines.py::test_compare_engines_counts_a_zero_of_one_engine_as_failure.

Deprecated

  • Backend names cim, bem and image_nlayer (10.76). They keep working, emit a DeprecationWarning naming the replacement and are removed no earlier than 2027.5: cim runs the image auto-dispatch (image, image_2layer; bit-identical on every world compared), bem runs mom (it assembled the identical point-matching system; results move by ≤ 3.5e-16), image_nlayer is the name of the auto-dispatch target of image for MultiLayerSoil and keeps its own solve function, so Engine(backend="image") stays silent. Three or more distinct layers raise and name mom_sommerfeld. As a pure alias, cim has the capabilities of image: concrete-shell electrodes and kernel="line", which it rejected before, now run. The modules groundfield.solver.cim (with fit_complex_images) and groundfield.solver.bem stay importable; solve_cim and solve_bem warn and delegate. Their results carry the metadata of the backend that ran: cim_fit_used, cim_n_images, cim_rms, reduces_to, n_layers, h and rhos are gone, a direct call adds dispatched_to. fem is registered as experimental (ExperimentalBackendWarning, once per process). The registry entries are applied by the release coordinator. Tests: tests/test_engine_aliases.py.

Removed

  • Private helpers without a remaining caller: groundfield.solver.mom._carson_skin_metadata, groundfield.solver.bem._build_Z_collocation, groundfield.solver.cim._cim_self_kernel_factory; the re-imports of image-family helpers from mom, mom_sommerfeld, bem and cim.

Stream coup2: Carson baseline, skin effect, touching pairs, earth-return assembly

Added

  • Skin effect in the solve (10.37, opt-in): a conductor with resistance_model="skin" now changes the branch impedance per frequency: each of its branches (lumped branches and the half stubs of galvanic chains included) adds l_b · Conductor.skin_correction_per_length(f) to its diagonal, so the resistance becomes R_ac(f) and the internal inductance L_int(f) (exact solid-round Bessel solution). A conductor without an inductance model gets the resistance part only and makes the world frequency dependent. Through the solver, a 150 mm² Al PEN has R_ac/R_dc = 1.0556 / 1.2308 / 1.5496 at 250 / 550 / 1000 Hz. The default resistance_model="dc" changes nothing. Tests: tests/test_inductive_solver_integration.py::test_skin_model_raises_the_pen_resistance_at_1khz, ::test_skin_correction_of_an_inductive_conductor, ::test_skin_correction_covers_the_half_stubs_of_a_galvanic_chain, ::test_skin_effect_without_inductance_model_changes_the_resistance_only.
  • Tabulated Sommerfeld assembly (10.60, opt-in): build_sommerfeld_correction_matrices(..., method="tabulated") (and the single-frequency builder) groups the segments by depth and shares one table of the spectral integral S(ρ) per pair of depth groups and frequency (100 nodes, cubic spline in ln(ρ + z)); the outer quadrature of all segment pairs runs vectorised. Against a converged reference (200 instead of 24 ρ nodes per pair) it is closer than the per-pair rule: 1.7e-6 against 1.4e-5 of the largest entry on a 10-house street network (two-layer earth: 2.7e-6 against 3.6e-6; lines 1 cm below the surface: 8.0e-7 against 6.1e-5); the substation impedance agrees with the converged reference to 5e-10 (per-pair rule 1.1e-8). On R8's W3 network a full solve with 11 frequencies takes 2.6 s instead of 27 s CPU (10 houses) and 7.8–9.1 s instead of 242 s (30 houses, 249 inductive branches; impedances equal to 3e-8). Blocks whose λ grid cannot be resolved (conductors in the surface plane across a large network) keep the per-pair rule. The solver selects it through the engine attribute sommerfeld_assembly ("exact" when absent); the default stays the per-pair assembly. Tests: tests/test_sommerfeld_tabulated.py.

Changed

  • ⚠ Exact touching segment pairs by default (10.46): chain neighbours and bends share an end point where the Neumann integrand is log-singular; the 16×16 Gauss–Legendre rule is −0.3 % … +0.8 % off for such pairs. The solver and build_inductance_matrix, neumann_mutual, perfect_mirror_self_pair_inductance now use the closed forms (touching="exact"); touching="quadrature" reproduces 0.15.0. A straight conductor keeps the inductance of the unsplit wire for every discretisation. Every result with an inductive conductor moves: 1.2e-6 (50 Hz) and 2.3e-5 (1 kHz) on the substation impedance of R8's 2-house street network (1.2e-4 at 1 kHz on the 30-house network, together with the lumped-branch fix below), ≤ 3.2e-6 in the golden cases cond_galvanic_neumann_perfect_mirror, cond_galvanic_neumann_carson_series, cond_galvanic_neumann_sommerfeld, defaults_mixed_cluster_inductive, line_cond_galvanic_neumann, cond_coupled_leads_open_circuit, cond_isolated_pen_sommerfeld_two_layer, gen_tn_measurement_overhead_leads, fit_rho_f_standard_sweep.
  • sommerfeld on the image-free baseline (10.46): the solver assembles the Neumann matrix and the Sommerfeld correction against free space (image="none") instead of adding the additive image and removing it again: exact, cheaper, the same numbers to round-off (≤ 4e-18 relative). Golden cases: the three sommerfeld cases, round-off only.
  • One earth-return assembly for all frequencies (10.60): the solver builds the Sommerfeld or Carson correction for the engine's whole frequency set at once on first use (geometry, λ grid and Bessel tables once per segment pair); every frequency is bit-identical to a single-frequency assembly. Sommerfeld matrices of R8's W3 network for 11 frequencies: 7.4–8.2 s → 1.5–1.9 s CPU (2 houses), 137–141 s → 27–28 s (10 houses); Carson matrices of W3c (30 houses): 4.4 s → 2.4 s. Full solves (with the wave-1 gains): W3, 2 houses 35.3 s in 0.15.0 → 2.1 s; W3, 30 houses about 3 600 s (review estimate) → 242 s; W3c, 30 houses 16.4 s → 3.3 s. The correction keeps at most 256 MiB of matrices (longer sweeps are assembled in chunks). Golden cases: none. Tests: tests/test_inductive_solver_integration.py::test_sommerfeld_pair_work_does_not_grow_with_the_number_of_frequencies, ::test_branch_correction_is_built_once_for_all_frequencies, ::test_branch_correction_memory_bound_keeps_the_numbers.

Fixed

  • ⚠ carson_series on the wrong image baseline (10.20, F32): Carson's correction (ωμ₀/π)(P + jQ) is defined against the anti-parallel image, but the solver added it on top of the additive image of ADR-0004, which counts the image twice: the earth-return reactance of a 1 km PEN was 2.04× (50 Hz) and 2.19× (1 kHz) Carson's value. The solver now builds the inductance matrix with image="antiparallel"; the 1 km PEN matches l·X′_Carson(GMR = a·e^(−1/4)) to 7e-6 (50 Hz) and 4.2e-4 (1 kHz). On R8's W3c network (30 houses, PEN Neumann) the substation impedance at 1 kHz drops from 0.4288 + 0.3439j Ω to 0.3964 + 0.2301j Ω (|Z| −16.6 %). Affects every carson_series result with an inductive conductor (all backends that share the inductive assembly). Golden case: cond_galvanic_neumann_carson_series (6.0e-3). Test: tests/test_inductive_solver_integration.py::test_carson_series_reactance_matches_carson.
  • ⚠ Carson's small-a series (10.46): for a ≤ 0.25 only the leading terms were used (no a² term −(π/64)a²cos2θ of Q, constants rounded): P and Q were up to 2.4e-4 and 3.0e-3 off at a = 0.25, and the θ = 0 quadrature above it 6.4e-6. The series is now summed to a¹² with the exact constants and the θ = 0 quadrature uses a graded composite rule; both are at round-off against mpmath and the regime boundary is continuous. Moves carson_series results (included in the bound of the entry above). Tests: tests/test_carson_pq.py::test_small_a_regime_is_continuous, ::test_small_a_series_matches_an_independent_quadrature, ::test_theta_zero_quadrature_is_at_round_off.
  • ⚠ Neumann inductance of lumped and single-segment conductors (10.24): a conductor with inductance_model="neumann" that the topology keeps as one lumped branch (discretize_segment_length=None, or a single sub-segment) lost its inductance silently: a 300 m PEN was 0.0564 + 0j Ω at 1 kHz. It is now one inductive branch from start to end, coupled to every other inductive branch (0.2101 + 3.7839j Ω with sommerfeld; a 10 m chain gives 0.2096 + 3.7840j Ω; with perfect_mirror and carson_series the single branch equals the refined chain to 1e-9). Affects PEN service drops shorter than the PEN segment length (5 m by default) and lumped leads when the conductor is inductive; on R8's 2-house street network the substation impedance moves by 1.3e-6 at 1 kHz. Golden cases: none. Tests: tests/test_inductive_solver_integration.py::test_neumann_is_honoured_on_lumped_and_single_segment_conductors, ::test_lumped_branch_equals_the_distributed_chain, ::test_lumped_inductive_conductor_couples_to_a_parallel_chain.
  • Conductors that leave the soil under sommerfeld (10.46, F52): a conductor crossing z = 0, or lying in the surface plane, is solved with the default earth model (the pair integrals split it at the surface; a PEN in the plane agrees with one 1 mm below it to 1e-7); with perfect_mirror and carson_series its image is singular and the solve raises as before. Tests: tests/test_inductive_solver_integration.py::test_sommerfeld_accepts_a_surface_crossing_conductor, tests/test_audit_guards.py::test_surface_pen_with_neumann_is_continuous_under_sommerfeld.
  • Invalid escape sequences in coupling.inductance docstrings (audit A1-12, 10.95): three docstrings raised SyntaxWarning on compilation (an error under python -W error), and \text in the module docstring turned into TAB characters; they are raw strings now. Tests: tests/test_coupling_conventions.py::test_modules_compile_without_invalid_escape_sequences, ::test_docstrings_contain_no_control_characters.
  • segment_distance with a zero-length segment (audit F04, 10.44): a point segment was measured from the start of the other segment (5.099 m instead of 1.0 m for a point 1 m beside the middle of a 10 m cable), so find_close_wires / find_close_conductors missed a point-like bond 2 cm from a cable; points now take the clamped orthogonal projection. Tests: tests/test_conductor_proximity.py::test_segment_distance_with_point_segments, ::test_point_like_bond_next_to_a_cable_is_reported.

Stream fitx: Touch-voltage envelope, formula renderer, passivity

Security

  • Formula parser cost is bounded for sums, products and powers (10.01; audit 1, H1, H2, L1, L2): formulas inside every documented limit could still cost minutes (times below: fresh process on a shared machine). A sum of fractions with distinct 15-digit prime denominators, ((b+2)/b)**64 per term, took 22 s (120 terms) and 105 s (222 terms) before it was rejected, because the bound was checked after SymPy had built the common denominator; the least common multiple of the fraction coefficients is now accumulated term by term before the sum is built, and the formula is rejected at the second term (0.05 s). Accepted products such as 332 logarithms (13 s) or 111 vanishing log sums (55 s) re-evaluated the growing product with evalf after every factor (2 802 and 2 857 evalf calls); values now come from a numeric shadow evaluation (mpmath, 128 bits) computed once per node, and chains of 32 or more factors are multiplied pairwise (2.1 s and 0.8 s; 176 and 110 evalf calls, all SymPy's own). (exp(600)*f)**64 was accepted as f**64*exp(38400): the power bound now includes the symbol-free factor of a product base, and every symbol-free sub-expression of the result is bounded (f*exp(600)*exp(600) is rejected). The documented exponent (-3/2) (Python reads (-3)/2) is accepted, so format_impedance_formula output such as f**(-3/2) parses. A deterministic budget, MAX_WORK = 200 000 bookkeeping steps, caps every parse. Exported formulas parse to the same values as before. tests/data/formula_corpus.json gains 4 accepted and 6 rejected audit strings for groundinsight's guard. Tests: tests/test_formula_security.py::test_sum_of_fractions_with_distinct_denominators_is_rejected_quickly, tests/test_formula_security.py::test_long_product_chains_parse_in_bounded_time, tests/test_formula_security.py::test_symbol_free_factor_of_a_power_base_is_bounded, tests/test_formula_security.py::test_negative_rational_literal_exponents_are_accepted.

Added

  • touch_voltage_envelope(..., interior=...) (10.21): samples the inside of closed loops, the analogue of the IEEE Std 80 mesh voltage (the worst touch voltage inside a mesh, near its centre). interior=None (default): the mesh centres of mesh / grid_mesh electrodes and the centre of a ring, i.e. loops in open ground; a closed polyline, the generators' building-outline foundation, is not sampled because the building stands inside. interior=True adds the point inside a closed polyline farthest from its wires (non-convex outlines stay inside); interior=False gives the offset curve only. The default cannot see buildings: pass interior=False for an axis-aligned generated foundation (grid_mesh) or a ring around a station housing. It replaces the mesh_centres= keyword added earlier in this release; anchor="connection_point", interior=False reproduces v0.15.0. Test: tests/test_touch_voltage_envelope.py::test_ring_envelope_samples_the_ring_centre_by_default.
  • Fit metadata in BusType documents (10.19, 10.27): standard-form exports record all coefficients k0 ... k5, fit_quality.max_relative, the weights and the fitted impedance quantity ("input", "cluster", "electrode", or null for raw samples); vector-fit exports record fit_quality.rms_relative and quantity. fit_quality_summary names them. Test: tests/test_io_groundinsight.py::test_fit_metadata_records_which_impedance_was_fitted.
  • MAX_WORK in groundfield.io._formula (see Security).

Changed

  • One formula renderer (10.73): fit_to_sympy keeps its signature but returns the partial fractions of the fit (one term per real pole or conjugate pole pair) instead of passing them through sympy.simplify, which merged them into one rational function: 6 of reviewer R5's 98 vector fits had a term above second order (s**4 over s**3 for a pole pair, a real pole and L_inf), now none. fit_to_sympy, fit_to_sympy_standard and the groundinsight exporter share one builder (one pole-pairing rule) and one rounding rule: every coefficient is rounded once to decimals significant digits (decimals must be a positive integer, also a NumPy integer, and every other value raises ValueError; above 17 counts as 17). Accuracy is unchanged: worst deviation from fit.evaluate over R5's fits 4.0e-6 at 6 digits and 4.8e-12 at 12. Exported vector-fit formulas are unchanged character for character; exported standard-form formulas keep every coefficient and value, but a complex coefficient now keeps its own sign (- f*(12.5592 - 1338.31*j) is written + f*(-12.5592 + 1338.31*j); 23 of R5's 31 standard fits). Test: tests/test_fit_formula_renderer.py::test_fit_to_sympy_keeps_one_term_per_pole_or_pole_pair.
  • ⚠ One passivity check (10.40): the BusType export runs check_passivity (on the rounded formula it writes) instead of its own implementation, so both use one band, 0 Hz to twice the highest fitted frequency (the default of check_passivity was the highest fitted frequency: a fit with Re Z = -1.0 Ohm at 1.5 kHz, passive at every sample up to 1 kHz, passed check_passivity but failed the export), the pole-adapted grid with the midpoints between samples, an exact corner check for the standard form, a tolerance of 1e-9 max|Z|, and non-finite values fail (a pole at s = 0 passed check_passivity). PassivityReport.as_dict() is the strict-JSON metadata["passivity"] block (passed, min_re_Z_Ohm or null, f_at_min_Hz, rho_at_min_Ohm_m, f_checked_Hz, rho_checked_Ohm_m, n_points); PassivityReport gains n_points. Affected: callers of check_passivity without f_max, whose verdict now covers twice the band (fits that passed may fail); impedances do not move. Golden cases: none. Test: tests/test_passivity.py::test_violation_between_the_highest_sample_and_twice_it_is_found.
  • rho_at_fit for layered soil (10.84): the error message and the export docstrings state one convention, the resistivity of the upper layer, rho_1 (the parameter of the standard form's rho_1 sweep), so vector-fit and standard-form BusTypes pair with the same groundinsight Bus. Test: tests/test_io_groundinsight.py::test_rho_at_fit_convention_for_layered_soil_is_the_upper_layer.
  • CSV frequency column frequency_hz (10.69): the column the electrode and cluster tables gain in this release, and the header keys frequency_hz / frequencies_hz, use the lower-case unit suffix of the spec layer and of FieldResult.to_dataframe. The potential path keeps its v0.15.0 column frequency_Hz. Test: tests/test_io_csv.py::test_new_frequency_column_uses_the_lower_case_unit_suffix.
  • Footprint from the electrode geometry (10.79): the touch-voltage footprint reads the wires from Electrode.wire_polylines() instead of a per-kind re-implementation (a ring keeps its exact circle). Foot positions are unchanged up to round-off (at most 1.4e-14 relative in the touch voltage, 2.3e-10 at UTM coordinates). Test: tests/test_touch_voltage_footprint.py::test_mesh_centres_lie_midway_between_the_discretiser_wires.

Fixed

  • ⚠ Touch voltage of rotated foundations (10.21; audit 1, H4): the generators build a foundation that is not axis-aligned from bonded wires <name>, <name>_w1, ... (10.39), and with 10.54 every OSM house foundation is rotated. The footprint came from the named edge wire only: for a 10 m x 10 m 2 x 2 mesh at 30 deg (100 Ohm m, 100 A) touch_voltage read 214.4 V on +x / -x and 93.9 V on +y (feet 1 m inside the building), 31 of 72 envelope feet lay inside the foundation and no cell centre was sampled. The footprint is now every wire of the foundation (from any of its names, within its galvanic cluster) and the envelope samples the cells of the rotated grid: 161.5 V on every side (167.5 V at 0 deg; one uniform current per wire instead of per grid), no foot inside. Affected: touch voltages at rotated foundations, i.e. OSM-based layouts. Golden cases: none. Test: tests/test_touch_voltage_footprint.py::test_touch_voltage_of_a_rotated_foundation_matches_the_unrotated_one.
  • touch_voltage_spectrum counted a frequency twice (10.52; audit 1, L4): a frequency carried by two results entered the RMS twice (701.6 V instead of 496.1 V); it now raises ValueError naming the frequency. Test: tests/test_safety.py::test_touch_voltage_spectrum_rejects_a_frequency_given_twice.
  • Strict-JSON fit metadata (10.27): hand-built standard fits wrote max_relative as NaN, which is not JSON; non-finite quality figures are now null. Test: tests/test_io_groundinsight.py::test_metadata_of_hand_built_fits_is_strict_json.
  • ⚠ Envelope of a ring includes its centre (10.21): a consequence of interior=None above; where the centre dominates, the envelope maximum rises (ring of 10 m radius at 0.8 m, 100 Ohm m, 100 A: 139.4 V on the offset curve, 182.6 V in the centre; a 4 m ring's centre, 346.0 V against 360.2 V, does not). Affected: envelopes of ring electrodes. Golden cases: none. Test: tests/test_touch_voltage_envelope.py::test_ring_envelope_samples_the_ring_centre_by_default.

Deprecated

  • Nothing.

Stream fixsec: Formula parser: resource bounds

Security

  • Formula parser: SymPy no longer factorises numbers or rewrites exp(c*log(x)) while parsing (10.01): strings inside the allow-list grammar still kept SymPy busy for minutes. SymPy simplifies a fractional power of an exact number by factorising the number and keeps a radicand of up to q - 1 times its digits: (N)**(63/64) with the 300-digit N = 10**300 - 1 (also written (f*N)**(63/64), (-N*f*rho)**(63/64) or (N/8)**(63/64)) keeps a radicand of about 18 800 digits and tests a 16 280-digit factor of it for primality, and 18**(10**30/(10**30 + 1)) needs 2**(10**30). It also rewrites exp(c*log(x)) as x**c, whose exponent is no literal: exp(log(N)*63/64) factorises like the power, exp(log(2*f)*10**12) builds 2**(10**12). Of 19 such strings (four reported by the groundinsight stream), 15 did not finish within 20 s, three took 1.8 to 2.6 s and one was accepted. Now no exact number is left under a fractional power: a fractional power (x**(p/q), sqrt) of a symbol-free base is evaluated numerically, and the rational coefficient c of a product base is taken out as the float |c|**(p/q) (17 significant digits, principal branch); a powered sum with a float coefficient gets float coefficients throughout (SymPy 1.13, which the dependency range allows, takes the largest coefficient of such a sum out of the power: (2.0*f + N)**(63/64) did not finish within 10 s there); an exact number under a fractional power needs q <= 64 and digits times q <= 300 (MAX_ROOT_DENOMINATOR, MAX_RADICAND_DIGITS in groundfield.io._formula, the limits of groundinsight's guard); log() inside exp() is rejected before anything is built; log of a symbol-free argument other than a positive rational or a float is evaluated numerically (SymPy's log(r + r*j) and the square root of r + r*j/3 factorised numbers of about 1 800 digits: 0.7 to 1.4 s for 900-digit fractions r). Each of the 19 strings is now rejected in at most 3 ms. Exported formulas parse to identical expressions (all 119 accepted corpus formulas and 387 exporter outputs of reviewer R5's generator). tests/data/formula_corpus.json gains 18 resource-exhaustion strings and one out-of-grammar string, all rejected by groundinsight's guard as well; the corpus test now parses every rejected string first in a worker process with a 20 s deadline and a 1 GiB address-space limit, so a regression can neither hang the test run nor exhaust the machine. Tests: tests/test_formula_security.py::test_every_rejected_formula_is_rejected_quickly_in_a_worker_process, tests/test_formula_security.py::test_fractional_powers_of_large_exact_numbers_are_rejected_before_sympy, tests/test_formula_security.py::test_fractional_powers_of_exact_numbers_are_evaluated_in_floating_point, tests/test_formula_security.py::test_log_inside_exp_is_rejected, tests/test_formula_security.py::test_sum_with_a_float_coefficient_keeps_no_exact_coefficient_under_a_root, tests/test_formula_security.py::test_complex_numbers_with_large_fractions_are_evaluated_quickly.

Added

  • MAX_ROOT_DENOMINATOR (64) and MAX_RADICAND_DIGITS (300) in groundfield.io._formula (see Security).

Changed

  • ⚠ Hand-written formulas with roots or logarithms of numbers (10.01): sqrt(2), 3**(1/3), (2*pi*f)**(1/2), log(-2) or log(2*pi) now parse to floats of 17 significant digits instead of exact radicals and logarithms (log of a positive rational such as log(2) stays exact); evaluated values move by at most 3.6e-16 relative (2 units in the last place) in 17 sample formulas. Formulas that loaded before and are now rejected: log anywhere inside exp (e.g. exp(log(f)*3), which SymPy turned into f**3), and fractional powers of exact numbers beyond the new limits, e.g. 2**(1/65), (2*f)**(1/1000), a 5-digit integer under **(63/64) or the square root of a 151-digit integer; writing the number as a float (2.0**(1/65)) keeps such a formula valid. Affects hand-written BusType formulas only: groundfield's exporters write neither roots nor exp/log (checked for every exporter formula of the corpus). Golden cases: none (bit-identical). Test: tests/test_formula_security.py::test_fractional_power_limits_for_exact_numbers.

Stream gen2: Measurement loop, one concrete-shell mechanism, PEN junctions

Added

  • Reading of a simulated earth tester (10.17): groundfield.generators.measured_impedance(result, probe=None, source=None) returns the three-pole reading Z_meas = (phi_E - phi_S) / I per frequency: E is the earthing system the measurement current is fed into (the source's attached_to cluster), S the voltage terminal (meas_S of a network built with a probe lead, else the probe electrode). The two-pole reading (E-H) is result.input_impedance(). New constants MEASUREMENT_H_TERMINAL = "meas_H" and MEASUREMENT_S_TERMINAL = "meas_S"; PlannedMeasurement.terminals and NetworkPlan.all_junctions carry the instrument terminals of a plan. Test: tests/test_measurement_loop.py.
  • GroundingSystemSpec.plan_site(..., outline=): shapes the resolved foundations after the footprint once the random draws are made ("spec" by default). Test: tests/test_footprint_foundations.py::test_footprint_outline_does_not_shift_the_random_draws.
  • groundfield.generators.grounding.MIN_FOUNDATION_SIDE_M (1 m): shortest side of a foundation taken from a footprint's oriented bounding rectangle.

Changed

  • ⚠ Measurement leads end on the instrument (10.17): in TnNetworkGenerator measurement set-ups the feed lead runs from the junction meas_H to the auxiliary electrode and the probe lead from meas_S to the probe (both junctions at the substation position, at the lead height); the source drives the test current between the substation and meas_H (return_to; the auxiliary electrode itself without a feed lead). With both leads, meas_S lies the touching distance (sum of the two wire radii) beside meas_H, so an in-line probe lead runs beside the feed lead instead of through it. Numbers of every measurement world with leads change completely: the old probe lead bonded the probe to the substation (reading 2.8e-4 instead of 1.6096 ohm in a 3-house network) and the old feed lead closed the loop metallically (99.93 % of the current never reached the soil). Golden cases: gen_tn_measurement_overhead_leads (auxiliary rod -1 A instead of +0.024 A, network potentials -1.8 %).
  • ⚠ One concrete-shell mechanism (10.12, 10.13, 10.14): both concrete_model values put the Sunde coefficient C = rho_c / (2 pi) ln(r_b / r_a) and the radius r_b = r_a + t on every encased (perimeter) wire; nothing is written to World.concrete_shell_corrections any more and PEN service drops keep their geometric resistance. "lumped" keeps one grid-mesh owner for an axis-aligned ring foundation (exactly the lumped resistance C / L_perim), "distributed" uses one owner per wire; polygon, rotated and mesh foundations are the same for both. Mesh braces are not encased (bare radius, C = 0); this also moves "distributed" mesh foundations, whose braces had the inflated radius (4-house network, 2 x 2 mesh: +2.6 / +7.8 / +12 % at rho_c = 150 / 1000 / 5000 Ohm m). The shell now reaches solve_mutual_matrix / solve_mutual_field (the AP1 Z_G path), Engine.solve of build_at worlds, the layout builder and substation / cabinet foundations. AP1-like site (rho_c = 100 Ohm m, 5 cm, 12 polygon foundations): house Z_G diagonal +42 / +19 / +2.8 % at rho_1 = 30 / 100 / 1000 Ohm m against v0.15.0, network input impedance +13.6 / +8.8 / +2.2 %; with rho_c = rho_soil the shell is transparent (0.0 %). Affected: every world with concrete_rho_ohm_m set. Golden cases: mutual_foundations_lumped_concrete (Z_G diagonal +42.2 %).
  • ⚠ PEN cable joints are junction nodes (10.38): the layout builder's cable corners and tap points are leakage-free Junction nodes (reported in result.metadata["junction_potentials"]) instead of 5 cm driven rods, which leaked 0.24 to 0.53 % of the test current at full foundation penetration and 3.7 % at 5 % penetration (substation potential +0.07 ... +0.33 % and +3.5 %). The joints are no electrodes any more. Golden cases: gen_layout_builder (+0.33 % potentials, +0.43 ... +0.57 % currents).
  • ⚠ PenConfig.depth_m is honoured: every PEN section and service drop of TnNetworkGenerator runs horizontally at z = depth_m between its anchors (it ran straight between the electrode connection points, e.g. from the substation ring at 0.6 m to a cabinet rod head at 0 m); depth_m must be
    1. 10-house network: resistive PEN -2.7e-7, bare galvanic PEN -1.4 %, Neumann PEN at 1 kHz X 0.736 -> 0.167 ohm (the old sections ended in the surface plane, where the perfect-mirror image meets the wire). Golden cases: gen_tn_default (<= 3.5e-7).
  • Layout reading uses the solved test current: LvNetworkLayout.measured_grounding_impedance and verify_current_balance take source_magnitude_a=None by default and read the current of the solved substation source (was 1 A unless repeated by the caller). Test: tests/test_measurement_loop.py::test_layout_reading_uses_the_solved_source_current.
  • Overpass response cap 64 -> 16 MiB: DEFAULT_MAX_RESPONSE_BYTES also bounds the decoding memory (6x the body for building payloads, 25x for a body of empty objects); the largest AP1 payload is 3.0 MiB. Pass max_response_bytes for wider areas. Test: tests/test_overpass_ingest.py::test_default_response_cap_bounds_the_decoded_size.
  • Naming rule of the spec layer (10.69): spec fields carry lower-case unit suffixes; the soil specs are the deliberate exception and mirror the literature symbols of their soil model (rho, rho_1, rho_2, h_1, h). Test: tests/test_generator_naming.py::test_soil_specs_mirror_their_soil_models.

Fixed

  • Measurement leads short-circuited the instrument (10.17): resistive leads now leave the reading unchanged (1.609633 ohm with and without leads; the feed lead adds its resistance to the two-pole reading only). Tests: tests/test_measurement_loop.py::test_resistive_leads_do_not_change_the_reading, ::test_feed_lead_adds_its_resistance_to_the_loop_impedance, ::test_two_terminal_reading_is_the_superposition_of_one_terminal_solves, ::test_in_line_leads_lie_side_by_side.
  • Lumped concrete shell dropped outside TN service drops (10.12): Test: tests/test_concrete_one_mechanism.py::test_lumped_polygon_foundation_equals_the_distributed_one, ::test_lumped_shell_resistivity_moves_the_mutual_matrix.
  • Rods and braces leaked through the foundation's shell; substation and cabinet shells dropped (10.13): lumped vs distributed +1.4 / +9.7 / +26.8 % (foundation + rod) and +9.6 / +56 / +148 % (mesh foundation) in v0.15.0, now within 2 % and identical. Tests: tests/test_concrete_one_mechanism.py::test_mixed_site_lumped_equals_distributed, ::test_mesh_braces_are_not_encased, ::test_substation_and_cabinet_shells_are_consumed.
  • Layout builder ignored the concrete shell (10.14, F08): Test: tests/test_concrete_one_mechanism.py::test_layout_builder_honours_the_shell.
  • PEN junction rods leaked current (10.38): Tests: tests/test_pen_junctions.py::test_the_earthing_system_carries_the_whole_test_current, ::test_a_resistive_cable_through_joints_equals_one_series_resistor.
  • PenConfig.depth_m had no effect: Test: tests/test_pen_depth.py.
  • Malformed Overpass payloads (10.05; audit M1): elements with wrong types crashed the parser with AttributeError / TypeError after the payload had been cached (every later call crashed from the cache); NaN / 1e308 / lat 95 vertices gave NaN-area footprints that passed min_area_m2. Every element and vertex is validated before caching and parsing (OverpassError), and a cached payload that fails the check is fetched again. Tests: tests/test_overpass_ingest.py::test_malformed_elements_raise_overpass_error, ::test_non_finite_or_out_of_range_vertices_are_rejected, ::test_malformed_payload_is_neither_cached_nor_parsed, ::test_malformed_cache_file_is_refetched.
  • Footprint outline shifted the random draws (10.54; audit M2): with a stochastic foundation size the "ombr" default skipped the size draw and moved optional rods to other houses (6 -> 8 rods). Test: tests/test_footprint_foundations.py::test_footprint_outline_does_not_shift_the_random_draws.
  • Degenerate footprints broke to_world (10.54; audit L5): a 10 m x 5 mm outline is widened to a 1 m foundation with a warning. Test: tests/test_footprint_foundations.py::test_a_degenerate_footprint_gets_a_minimum_foundation.
  • Layouts pickled with v0.15.0 (10.69; audit L6): to_world raised AttributeError: 'cabinet_placements'; kvs_placements is migrated on unpickling. Test: tests/test_generator_naming.py::test_layout_pickled_with_v0150_still_builds.
  • Inert permittivity of soil specs (10.51; audit A1-10): a non-default relative_permittivity of a soil spec now warns with InertConfigurationWarning when the soil is built (it was dropped silently on the generator path). Test: tests/test_soil_specs.py::test_inert_permittivity_warns_on_the_generator_path.
  • Carriage return in a docstring (10.95): the soil-spec module docstring held \rho in a non-raw string. Test: tests/test_generator_docstrings.py::test_generator_docstrings_contain_no_control_characters.

Removed

  • Unreleased names of the first 2026.11 consolidation: PlannedBranch.concrete_shell_of and materialise.PEN_JUNCTION_ROD_LENGTH_M.

Stream fix1: Fixes from the first adversarial audit

Added

  • Engine.sommerfeld_assembly (10.60): "exact" (default) or "tabulated" assembly of the Sommerfeld earth-return correction of inductive conductors, a validated engine field (also a create_engine parameter, recorded in the provenance). The solver read it through getattr on a field that did not exist. Tests: tests/test_sommerfeld_tabulated.py::test_the_assembly_is_a_validated_engine_field, ::test_solve_with_an_engine_that_selects_the_tabulated_assembly.

  • create_conductor(resistance_model=...) (10.37): the opt-in skin effect ("skin"; default "dc") is reachable through the factory; it was accepted by Conductor(...) only. Test: tests/test_api_factories.py::test_create_conductor_reaches_the_skin_effect_model.

Changed

  • One error type when a backend cannot take the soil model (audit A1-08, F09): the backend functions called directly raise BackendCapabilityError like Engine.solve does: solve_image with a layered soil, solve_image_2layer with a homogeneous soil, solve_image_nlayer and solve_mom with three or more distinct layers, and the concrete-shell guard of the mom family. BackendCapabilityError subclasses ValueError and NotImplementedError (the types of image_nlayer, cim, bem and the shell guard in 0.15.0), but not TypeError: code that caught TypeError from image_2layer (homogeneous soil or layer stack) or mom (three or more layers) must catch BackendCapabilityError or ValueError. TypeError stays for a world.soil that is no soil model. Tests: tests/test_soil_capability_errors.py, tests/test_api_smoke.py::test_solve_image_directly_rejects_non_homogeneous.
  • Engine copies and assignments are validated (audit A1-02, A1-04): Engine.model_copy(update=...) validates the update like the constructor (unknown keys raise with a suggestion; only warnings that the update introduces are emitted), every field is validated on assignment (engine.frequencies = [] raises), and entries put into Engine.options in place are validated when they are read (backend_options, solve). Engine.options and BackendCapabilities.soils / conductors / kernels are annotated with the accepted input types (mappings, sets), so the documented calls type-check (audit A1-06).
  • Soil keyword typos are type errors again (audit A1-09): the deprecated soil names resistivity / thickness are translated in a model validator instead of validation_alias=AliasChoices(...), which made the pydantic mypy plugin accept any keyword (HomogeneousSoil(rhoo=100.0) passed). Runtime behaviour is unchanged (deprecation warning, 0.15.0 JSON loads, a rejected value is reported under the name it was given); type checkers now also report the deprecated keywords. Test: tests/test_typing_contract.py.
  • W605 joins the blocking lint subset (audit A1-12): pre-commit and CI run ruff check --select F,E9,B,W605; an invalid escape sequence (a SyntaxWarning today, a SyntaxError under python -W error and in a future Python) no longer passes. The 35 findings of the blocking subset in tests/ were cleared outside the generator / geo test modules.
  • Release tool checks the remote (audit A1-11, 10.09): before anything is written, scripts/release.py reads the upstream branch and the remote tags with git ls-remote (no fetch, --dry-run changes nothing): a clone that is behind or has diverged from its upstream is refused, remote tags count for the MICRO of calver and for "the tag exists", an unreadable remote or a branch without upstream (in a repository with a remote) aborts; a repository without any remote is released with a note. A stale clone used to create a second, different v2026.11.0 that only the push rejected. Tests: tests/test_release_script.py.
  • solve_mutual_matrix / solve_mutual_field assemble the inductive branch correction for the solved frequency only (10.60): an engine with four frequencies built the correction four times per call, now once; results are bit-identical. Test: tests/test_mutual_matrix.py::test_one_call_assembles_the_branch_correction_for_its_frequency_only.

Fixed

  • ⚠ A galvanic conductor with one sub-piece leaks (10.24, galvanic half): a distributed conductor with coupling_to_soil="galvanic" whose discretize_segment_length is at least its length fell back to the leakage-free lumped branch. Two 2 m rods 30 m apart joined by a bare 50 mm² conductor in 100 Ω·m: input impedance 22.74 Ω with one sub-piece against 5.54 Ω with two (line kernel; point kernel 22.36 Ω against 6.91 Ω); now 5.54 Ω (point kernel 8.59 Ω, the coarsest member of its convergence sequence towards 5.48 Ω). The sub-piece is one midpoint pseudo-node between two R/2 stubs and also carries its inductance with inductance_model="neumann". Affects only galvanic distributed conductors shorter than discretize_segment_length (no golden case; isolated ones keep the lumped branch). A single sub-piece is as accurate as the kernel is for a long segment: with the line kernel it is converged in homogeneous soil and in two-layer soil without an electrode through the interface (12.134 Ω against 12.136 Ω with 32 sub-pieces, 300 over 50 Ω·m, h₁ = 2 m); with an electrode through the interface the cross-layer correction needs sub-pieces of the order of h₁ (one: 7.18 Ω, four: 9.41 Ω, 32: 9.50 Ω). Tests: tests/test_conductors_distributed.py::test_a_single_segment_galvanic_conductor_leaks, ::test_a_single_segment_galvanic_conductor_keeps_its_inductance.
  • Deprecated flat names in Engine.model_copy (audit A1-02): engine.model_copy(update={"sommerfeld_epsrel": 1e-2}) was silently ignored (the copy ran with 1e-7; the name is a deprecated property that shadowed the stored value). The flat sommerfeld_* names are now mapped onto options["mom_sommerfeld"] with a DeprecationWarning, also back to a default value. Tests: tests/test_engine_validation.py.
  • Engine assignments (audit A1-04, engine part of 10.67): engine.options = {"fem": {...}} stored a raw dict and the solve failed with an AttributeError (a misspelled option was never named); engine.frequencies = [] returned an empty result and [nan] solved. Tests: tests/test_engine_validation.py.
  • Result files honour the umask (audit A1-05): save_result wrote mode 0600 (tempfile.mkstemp); new files now get 0666 reduced by the umask (0644 under 022), an overwritten file keeps its mode. Tests: tests/test_result_persistence.py::test_result_file_mode_follows_the_umask, ::test_overwriting_keeps_the_mode_of_the_replaced_file.
  • ShallowSegmentWarning follows the kernel (audit F08): the advisory quantifies the bias of the point-form self image of a segment longer than four times its depth. It was also emitted for the exact line kernel (the image family's default), which has no such bias: a 10 m strip at 0.1 m depth gives 17.37863 Ω with 2 m segments and 17.37859 Ω with 0.25 m ones (point kernel 21.57 Ω and 17.23 Ω). It is now emitted for the point kernel and the mom family only, names the line kernel as the remedy and no longer claims that the mom family stays silent. Tests: tests/test_shallow_segment_advisory.py.
  • Stale docstrings (audit A1-07): create_engine (backend-specific settings such as the mom_sommerfeld accuracy controls go into options, not the deprecated flat fields), groundfield.solver (the registered backends instead of "reserved" MoM / FEM), the engine's family overview (cim / bem aliases, fem experimental), Engine.earth_inductive_model (carson_series on the anti-parallel image, sommerfeld on the image-free matrix), the consumers of the series controls, and the branch block (skin term).
  • Control characters in docstrings (10.95): \rho in a non-raw docstring of the two-layer solver started with a carriage return (a valid escape, invisible to W605). Test: tests/test_source_escapes.py.

Security

  • Result files from untrusted sources (audit A1-01): the $ndarray decoder of FieldResult.metadata accepted any numpy dtype string: a 396-byte result file decoded to a 4 MiB unicode array, 413 bytes to an 8 MiB sub-array, and object arrays loaded. It now reads only what the encoder writes (bool, integer, float16/32/64, complex64/128 and unicode dtypes), checks that the shape matches the number of items and that every item is a scalar of the dtype's kind before allocating, limits string arrays to 64 bytes per character of their items (plus 4 KiB), bounds the nesting depth (MAX_METADATA_DEPTH = 100) and raises ValueError (pydantic.ValidationError through load_result) naming the metadata key for every malformed tag; load_result reports non-UTF-8 and too deeply nested JSON as ResultFormatError. The encoder applies the same limits. Tests: tests/test_result_metadata_codec.py.

Stream fix2solver: Fixes from the second adversarial audit: solver and engines

Added

  • groundfield.solver.PointKernelInterfaceWarning: warning category for a horizontal wire within 0.6 segment lengths of the layer interface on the point-form cross-layer path (see Fixed, point form of the cross-layer path).
  • expected_segments(...)["nodal_unknowns"] (10.06): the size of the dense augmented nodal system (current owners, nodes and branches, every conductor sub-piece included), an upper bound computed in closed form and checked against HARD_LIMIT like the segment count. Test: tests/test_diagnostics_report.py::test_nodal_unknowns_are_the_size_of_the_solved_system.

Changed

  • A world without a current source raises in every backend (10.66, audit A2S-05): Engine.solve validated with World.check(require_source=False), and an earlier entry of this release said such a world "stays solvable through Engine.solve (all results zero)". Only fem did; the image and mom families and World.solve raised. Engine.solve now runs the full check, so every backend and both entry points raise the same ValueError ("has no current source"), as the 10.66 concept lists. Test: tests/test_source_validation.py::test_a_world_without_a_source_raises_in_every_backend.
  • ⚠ TwoLayerSoil(rho, rho, h) is cut nowhere (10.48, audit A2S-07): image_2layer (also reached through image and the auto dispatch) cut wires at h even when both layers have one resistivity, while mom, mom_sommerfeld and image_nlayer did not. Every backend now cuts where the resistivity changes only (the canonical stack), so such a soil solves exactly like homogeneous soil: a rod 0.3–6.3 m in TwoLayerSoil(100, 100, 2.15) had 13 segments and sat 3.8e-4 (point kernel) and 3.3e-7 (line kernel) from the homogeneous result; now 12 segments, equal to 2.2e-16 and bit for bit. Who is affected: worlds with an equal-resistivity two-layer soil and a wire through h (not AP1: its station rods end above h_1). Golden cases: none. Test: tests/test_diagnostics.py::test_equal_resistivity_two_layer_soil_is_the_homogeneous_soil.

Fixed

  • ⚠ Interface contact (10.32, audit A2S-01): an interface cut that would leave a wire part shorter than the wire diameter was dropped, and the part joined its neighbour in the other layer, so the contact with that layer was ignored: a 4.5 m rod (a = 8 mm) in 1000/30 Ω·m read 195.0 Ω with its tip 15.9 mm into the lower layer and 128.6 Ω at 16.1 mm (+52 %), in image_2layer and the mom family alike, and the same at the head of a rod. Every interface cut is now kept, however short the part beyond it; the thin-wire guard concerns the chosen segment length only. The Galerkin self term (it lost every digit below L/a = 1e-8) and the line kernel's parallel-pair integral (two parts of 1e-11 m: 0 instead of 125 1/m, the rod read 72.7 instead of 133.5 Ω) are evaluated without cancellation for such parts; every regular segment keeps its arithmetic bit for bit. The impedance is now continuous in the penetration depth (line kernel 133.5 → 128.6 Ω from 10 pm to 16.1 mm, the same shape for the point kernel, mom and mom_sommerfeld); the step that remains is the onset of the contact itself between a tip that ends at the interface and one that reaches past it (195.9 → 133.5 Ω here). Who is affected: rods whose tip or head lies within 16 mm (two wire radii) of an interface: −34 % in this example. The constant geometry.electrodes.SLIVER_RADII introduced earlier in this release is gone. Golden cases: none. Tests: tests/test_interface_slivers.py (::test_every_interface_cut_is_kept, ::test_rod_resistance_is_smooth_in_the_tip_penetration, ::test_rod_resistance_is_continuous_in_h1_at_the_former_sliver_threshold, ::test_a_tip_twelve_millimetres_into_a_conductive_layer_is_felt, ::test_a_head_just_inside_a_conductive_upper_layer_is_felt, ::test_parallel_pair_integral_of_parts_much_shorter_than_their_distance).
  • ⚠ Point form of the cross-layer path (10.28, ADR-0007): with kernel="point" (and in the mom family, mom_sommerfeld with two layers and solve_mutual_* with the point kernel) the diagonal of the cross-layer reaction matrix averages the layered correction over a 3-point rule along the depth axis, ±0.387 L, whatever the segment's orientation. For a horizontal wire next to the interface the rule reached across it and returned wrong, even negative impedances (a rod through h₁ = 1.2 m with a 20 m strip at 0.8 m, 300/50 Ω·m, ds = 2 m: −19.37 Ω against 9.62 Ω with the line kernel; v0.15.0: −14.24 Ω; −14 % … −552 % over the measured cases), or reached above the soil surface and raised a bare ValueError about negative depths. Such worlds now raise BackendCapabilityError naming the line kernel (or image_2layer for the mom family) and a segment length that fits; a horizontal wire within 0.6 segment lengths of h₁ warns with PointKernelInterfaceWarning (−3 % … −17 %). Rods (cut at h₁) and every valid configuration keep their numbers; the default line kernel is unaffected. Golden cases: none. Tests: tests/test_cross_layer_point_form.py, tests/test_cross_layer_line_kernel.py::test_point_kernel_keeps_its_numbers_near_the_interface.
  • ⚠ fem below a thin top layer (10.23, audit A2E-2): the guard raised only when an interface lies between the hemisphere radius a_eq and the electrode's deepest point; a 3 m rod wholly below h₁ = 0.4 m < a_eq (1000/30 Ω·m) only warned and returned 31.1 Ω (mom: 10.5 Ω, +197 %). It now also raises when every electrode of a cluster lies below an interface between a_eq/2 and a_eq (more than half of the hemisphere in a layer the electrodes do not touch; +51 … +130 % and −81 … −98 % measured for a 3 m rod against image_2layer). Thinner top layers keep the warning (+16 … +46 %, −38 … −58 % for 100/1000 Ω·m), as do bonded rods through the top layer. Golden cases: none. Tests: tests/test_fem.py::test_fem_rejects_a_rod_below_a_top_layer_holding_most_of_its_hemisphere, ::test_fem_only_warns_below_a_thin_top_layer, ::test_fem_guard_applies_to_a_bonded_cluster_wholly_below_the_interface.
  • Resource guard (10.06, audit A2S-02): check_segment_budget counted leakage segments only, so every sub-piece of an isolated distributed conductor (a branch and an interior node of the dense nodal system and a row of the inductance matrix) counted as zero: a 100 m PEN in 2000 pieces predicted 12 segments and took 407 MiB, in millimetre pieces the solve died with a MemoryError. The guard now also predicts the unknowns of the nodal system in closed form and raises ResourceLimitError above HARD_LIMIT before anything of that size is allocated (an inductive chain before the inductance assembly); diagnose() reports it. Tests: tests/test_diagnostics_report.py::test_conductor_chain_beyond_the_limit_is_rejected, ::test_a_chain_in_millimetre_pieces_is_rejected_before_allocation, ::test_diagnose_reports_a_nodal_system_beyond_the_limit.
  • Floating clusters in solve_mutual_* (10.29, audit A2S-03): every excitation rebuilt the multi-port matrix of all floating clusters and factorised the full nodal system again, so the cost grew with the square of the number of bonded grounding nodes (256 ring-and-rod nodes: 199.9 s against 24.3 s before floating). The floating core is now assembled and factorised once with one right-hand side per anchor; an anchor outside the core enters through its coupling column. 256 nodes: 5.6 s; 100 rotated foundations of four bonded strips: 2.7 s (24.0 s); results equal to 1e-12 (golden values bit-identical). Tests: tests/test_mutual_matrix.py::test_shared_factorisation_equals_one_floating_solve_per_anchor, ::test_one_core_assembly_and_factorisation_for_all_anchors.
  • expected_segments for layer stacks (10.79, audit A2S-07): the prediction cut wires at every declared interface, the backends at the interfaces of the canonical stack only: a rod 0.3–6.3 m in MultiLayerSoil([100 Ω·m, h = 2.15 m], [100 Ω·m]) was predicted at 13 segments and solved with 12. One rule now feeds both. Test: tests/test_diagnostics.py::test_expected_segments_matches_the_solve_for_every_layer_stack.
  • fem ignored the skin effect silently (10.37, audit A2C-4): "skin" is a conductor feature of the backend registry; fem (lumped, DC) warns with BackendCapabilityWarning naming it, while image and mom raise the rod-to-rod voltage of a 300 m 150 mm² Al PEN by +54.9 % from 0 Hz to 1 kHz. A registered backend that lists its conductor features without "skin" warns too. Tests: tests/test_backend_registry.py::test_a_backend_that_ignores_the_skin_model_says_so, ::test_registered_backend_without_the_skin_feature_warns.
  • Duplicate names in a loaded or edited world (10.66, audit A2S-06): World.check() did not check that names are unique (only the add_* methods did): two electrodes of one name from JSON failed in the solver with a singular matrix, an electrode and a junction of one name were merged into one node. check() (run by every solve) now rejects a name used twice among the nodes, the conductors or the sources. Test: tests/test_source_validation.py::test_check_reports_names_used_twice.
  • convergence_study repeated show-once warnings (A1-02, audit A2S-08): it copied the engine per step with the validating Engine.model_copy, whose warning capture resets every module's registry; a shallow strip showed the same ShallowSegmentWarning once per step. It now copies internally and validates the segment lengths itself (finite and strictly positive). Tests: tests/test_convergence.py::test_convergence_study_shows_each_distinct_warning_once, ::test_convergence_study_rejects_non_finite_segment_lengths.

Security

  • Crafted result files (A1-01, audit A2S-04): a $complex metadata tag holding an integer beyond the float range ({"$complex": [10**400, 0]}, also inside $tuple, as a $dict key or an $ndarray item) escaped load_result as a bare OverflowError instead of the documented ValueError; it is now a ValueError naming the metadata key. Test: tests/test_result_metadata_codec.py::test_a_complex_tag_beyond_the_float_range_is_a_value_error.

Stream fix2coup: Fixes from the second adversarial audit: coupling

Fixed

  • Cost of the exact touching-pair rule (10.46, audit A2C-5): the closed forms of coaxial segment pairs were evaluated with one Python call per pair, and on a straight conductor of M sub-segments all M(M−1)/2 pairs are coaxial: build_inductance_matrix took 2.4–3.2× (straight PEN, M = 100–800) and 7–26× (oblique PEN) the time of the 0.15.0 quadrature rule, and a solve of a straight 2 km PEN (400 branches, 2 frequencies) 2.2–2.6 s instead of 1.0–1.3 s CPU. The coaxial pairs of a segment are now evaluated in one vectorised call — bit-identical (the 3-element dot products go through the same BLAS routine, the logarithms through math.log): 0.9–1.6× the quadrature time on straight chains, 2.0–3.7× on oblique ones (where the quadrature rule uses the cheap parallel closed form; 0.07–0.26 s for M = 200–400), 1.1–1.4 s for the 2 km PEN solve. No number changes (golden cases bit-identical). Tests: tests/test_neumann_touching.py::test_scalar_closed_form_calls_grow_linearly, ::test_touching_batch_is_bit_identical_with_the_scalar_closed_forms, ::test_exact_rule_on_a_straight_chain_is_not_slower_than_twice_the_quadrature (benchmark).
  • ⚠ carson_series: an overhead wire over a buried one (10.20, audit A2C-1): the solver treated the buried wire of such a pair as an overhead wire at height |z| on the mirrored-endpoint image, whose image lands above ground next to the overhead wire. The mutual reactance per metre was 35.9 % low for a lead 1 m above a PEN at 0.7 m depth (1 kHz, 100 Ω·m), 13.5 % at 1 m horizontal offset, 3.4 % for a generator surface lead 0.1 m above ground, 10.3 % at 50 Hz. A perfect conductor screens the soil, so the anti-parallel baseline of a pair on opposite sides of the surface is now zero (build_inductance_matrix(image="antiparallel")), and its coupling is the field transmitted into the soil, new coupling.carson.carson_mixed_mutual_correction (Carson's J plus the bounded remainder of the buried wire's attenuation; Ametani et al. 2009): equal to an independent mpmath quadrature to 1e-9 and to the per-metre Sommerfeld kernel to 1e-3 at 1 kHz. Affects worlds with an overhead and a buried inductive conductor under carson_series; golden cases: none. Tests: tests/test_carson_validity_domain.py::test_overhead_wire_over_buried_wire_matches_the_transmitted_field, ::test_mixed_mutual_correction_matches_an_independent_quadrature, ::test_mixed_pair_agrees_with_the_sommerfeld_model_per_metre, ::test_antiparallel_baseline_of_a_pair_across_the_surface_is_zero, ::test_every_image_convention_gives_one_impedance.
  • ⚠ carson_series outside its validity domain (10.20, stream DOC-B): oblique segment pairs got sqrt(l_i l_j)·|cos φ| times the per-metre value once per segment pair, which grows with the number of segments: a probe lead turning 8.1° against the feed lead changed the measured reactance 17.6-fold, two 1 km leads at 9° gave 20× the Sommerfeld coupling. Carson's per-metre tiling is now kept for near-parallel pairs of near-horizontal segments only; oblique pairs and every pair and self term of a segment inclined by more than 8.1° get the exact Sommerfeld correction of a homogeneous earth of the same conductivity (tabulated assembly). At the boundary the result steps from the per-metre tiling to the Sommerfeld value by the model error of the tiling there: 12 % for two 1 km leads 2 m apart at 1 kHz; in the DOC-B measurement setup (93 m leads, 50 Hz, short against the 711 m skin depth) Im Z_meas goes from 0.032 Ω (6.2°) to 0.018 Ω (8.6°), which is the sommerfeld value. Affects carson_series worlds with oblique, inclined or vertical inductive conductors; golden cases: none. Tests: tests/test_carson_validity_domain.py::test_pairs_outside_the_domain_get_the_sommerfeld_correction, ::test_oblique_coupling_does_not_grow_with_the_number_of_segments, ::test_oblique_leads_couple_as_in_the_sommerfeld_model.
  • ⚠ Wires lying side by side (10.46, streams GEN-2 / DOC-B): two near-parallel segments whose axes stay closer than the sum of their radii over a common length (coincident leads, a service drop routed back along its PEN main) had no finite filament mutual inductance — the 16×16 rule stopped at its 1e-6 m floor: two coincident 50 m leads read 1.87 H of mutual inductance (+587j Ω at 50 Hz), and a two-house TN network whose drops ran back along the PEN main had a negative input reactance at 1 kHz (−0.633 Ω perfect_mirror, −0.643 Ω sommerfeld). Such pairs are now evaluated as touching wires at the axis distance r₁ + r₂ (in every image convention and in the image block), and carson_series gives two conductors overlapping on one axis the earth-return mutual of touching wires (it skipped them as "the same wire"). The two-house network now reads +0.244 / +0.233 / +0.250 Ω (perfect_mirror / sommerfeld / carson_series). Also moves the reading of the generator's in-line fall-of-potential setup, whose probe lead starts 1 cm beside the feed lead and ends on its axis: Im Z_meas at 50 Hz 0.063 → 0.054 Ω (sommerfeld). Golden cases: none. Tests: tests/test_interpenetrating_wires.py.
  • ⚠ sommerfeld: long segments (10.24, audit A2C-2): the earth-return correction of a segment pair was one 16×16 Gauss–Legendre rule over the two segments, which cannot resolve exp(−γR) along a segment much longer than the skin depth — every lumped inductive conductor is one such segment. At 1 kHz in 100 Ω·m (skin depth 159 m) the earth-return resistance of a straight buried conductor was +1.7 % (1 km), +13.4 % (3 km), +34.9 % (5 km) against the converged chain (+0.2 / +0.6 / +1.7 % at 50 Hz), and a lumped 3 km PEN between two rods read +11 % series resistance, without a warning. A segment longer than a quarter skin depth of the most conductive layer now gets a composite outer rule (16 nodes per piece, at most 512 pieces, beyond that a SommerfeldResolutionWarning) and an S(ρ) table as dense as a short pair's (24 nodes over a km-long range left 1–2e-3); frequencies with equal piece counts share one pass, so every frequency still equals a single-frequency assembly bit for bit, and the tabulated assembly splits the same way. The lumped conductors now match their chains to ≤ 1e-4 (3 km at 1 kHz: 2.78766 against 2.78773 Ω). Numbers move for every sommerfeld world with an inductive segment longer than a quarter skin depth — at 1 kHz 40 m (100 Ω·m), 22 m (30 Ω·m), 12.6 m (10 Ω·m); at 50 Hz 178 m (100 Ω·m) — by about 1e-4 just above that length up to tens of per cent for km-long lumped conductors; segments below it keep the historic rule bit for bit. Golden cases: none. Tests: tests/test_sommerfeld_long_segments.py.
  • ⚠ Neumann inductance of close, non-parallel segment pairs (10.46, found in audit round 2 while attacking the guard above): pairs that miss the closed forms — nearly parallel wires close together whose directions differ by more than 1e-9 in cos (about 0.003°), crossing and skew pairs — were integrated with the 16×16 rule, which only resolves 1/r for pairs apart by about half their length: two 5 m segments with aligned ends and 1e-5 … 1e-3 rad between them were +12 % at 10 cm and +200 … +250 % at 1 cm, −19 % at 1 mm with offset ends; crossing pairs about −1 % (−12 % when crossing near an end at 2°), skew pairs 1 cm apart −2.3 … +0.5 %, a branch starting on the interior of another segment (T-junction without a shared vertex) −3.5 … −13 %. With touching="exact" (the default) such pairs are now integrated semi-analytically (inner integral in closed form, outer Gauss–Legendre panels graded towards the near-singular points; ≤ 5e-11 against an adaptive reference); touching="quadrature" keeps the 0.15.0 numbers. Moves every inductive result with such pairs — conductors from real (non-axis-parallel) geometries running close together, the generator's in-line probe lead (starts 1 cm beside the feed lead, ends on its axis): feed–probe mutual 92.8 → 91.7 µH, the value of touching wires over the overlap plus the end-to-end coupling (91.65 µH). Golden cases: none. Tests: tests/test_neumann_close_pairs.py.

Stream fix2sec: Fixes from the second adversarial audit: formula parser

Security

  • Formula parser: SymPy no longer evaluates the expression being built (10.01): the second audit of the calendar release found two more evaluation paths that the parser's rules did not bound (after two rounds of rules against particular inputs): SymPy's exp asks whether the factors of its argument are comparable and expands powers of complex sums to find out, and Pow computes the real part and the argument of the inner base of (b**e)**(p/q); 67- and 75-character formulas such as exp(pi*(((pi/4 + j/2)**64 + pi/4 + j/2)**64 + pi/4 + j/2)**64/1e30) and (((((f/4 + j/2)**64/1000 + j/2)**64/1000 + j/2)**64/1000 + j/2)**63)**(1/2) ran for more than a minute. The class is fixed instead of the examples: every node is now built unevaluated (evaluate=False), and every number is computed by the parser itself in bounded floating point (128 bits, every bound checked before the operation) and stored as a SymPy float; within one product the numeric factors form one coefficient, within one sum the numbers are added and like terms collected (so 1/(f - f) and exp(f - f + 1000) stay rejected). Formulas within every limit that took 2.2 s to 3.3 s to parse before now take at most 0.04 s, every corpus string keeps its verdict, and the time of a parse grows linearly with the length of the formula. The exponents of nested powers now multiply to at most 64 (MAX_POW), the bound groundinsight's guard applies; the audit's strings are rejected within 3 ms. evaluate_spec and the exporter's passivity check evaluate the parsed expression node by node with NumPy (new formula_function) instead of sympy.lambdify, whose printer evaluates sub-expressions: 6.8 s for a 1 439-character formula within every limit, now 2 ms. tests/data/formula_corpus.json gains 16 resource-exhaustion and 2 out-of-grammar strings, all rejected by groundinsight's guard as well. Tests: tests/test_formula_security.py::test_nested_powers_of_audit_2_are_rejected_quickly, tests/test_formula_security.py::test_formulas_within_every_limit_parse_and_evaluate_quickly, tests/test_formula_security.py::test_parsing_and_evaluation_never_let_sympy_evaluate, tests/test_formula_security.py::test_evaluate_spec_does_not_use_sympy_code_generation, tests/test_formula_security.py::test_terms_that_cancel_within_one_sum_are_collected.
  • Formula parser: numeric literals outside the float range raise FormulaError (10.01): 1e- followed by 320 nines is a valid Python float literal that rounds to 0.0; the parser converted its exponent to a float and raised OverflowError, which leaked through load_bustype_json. Every literal, also in an exponent, is now bounded by its exact decimal value before any float is formed, and no arithmetic error leaves the parser as anything but FormulaError; a BusType document whose voltage_level or schema_version is outside the float range raises ValueError, and so does a crafted document that is nested too deeply for Python's JSON reader, is not a JSON object, lacks name, system_type or voltage_level, or has samples that are not numbers (it raised RecursionError, AttributeError or KeyError). Tests: tests/test_formula_security.py::test_numeric_literals_outside_the_bounds_raise_formula_error, tests/test_formula_security.py::test_load_bustype_json_reports_a_huge_literal_as_evaluate_spec_error, tests/test_formula_security.py::test_bustype_header_numbers_outside_the_float_range_raise_value_error, tests/test_io_groundinsight.py::test_crafted_bustype_documents_raise_value_error.

Added

  • formula_function(expr, symbols=("f", "rho")) in groundfield.io._formula: NumPy function of a parsed impedance formula, built from the expression tree without SymPy's code generation (real arithmetic for real values, as lambdify with NumPy; SymPy's principal branch for roots and logarithms of negative numbers). Test: tests/test_formula_security.py::test_formula_function_keeps_the_real_limits_at_singular_points.

Changed

  • ⚠ Form of a parsed impedance formula (10.01): parse_impedance_formula returns an unevaluated expression whose numbers are SymPy floats of 17 significant digits: 2*pi*f*j/1000 + 403191/50000 parses to (0.0062831853071795866*I)*f + 8.0638199999999998, log(2) to 0.69314718055994529; symbolic exp, log and powers keep the structure of the text. Code that compared parsed expressions with exact SymPy expressions must compare values instead. Evaluated values move by at most 4.1e-16 relative for the 103 exporter formulas of the corpus and 3.3e-15 for the hand-written ones (closer to a 50-digit evaluation than before: 1.5e-16 instead of 3.4e-15 for the worst one). Formulas that loaded before and are now rejected: nested powers whose exponents multiply to more than 64, also through sums and function calls and for powers of numbers, e.g. ((f**8)**8)**2 or (f*10**40)**2 (write 1e40), and exponent literals below 1e-300 such as f**1e-400 (which was read as f**0). evaluate_spec gives the principal-branch value where lambdify gave nan, e.g. (f - 100)**0.5 below 100 Hz. groundfield's exporters write neither nested powers nor roots, so exported formulas are not affected. Golden cases: none (bit-identical to the base of the change). Tests: tests/test_formula_security.py::test_exponents_of_nested_powers_multiply_to_at_most_max_pow, tests/test_formula_security.py::test_parsed_expression_is_unevaluated_with_numbers_as_floats, tests/test_formula_security.py::test_formula_function_takes_the_principal_branch_where_real_arithmetic_has_none.

Fixed

  • Strict JSON for unknown fit quality (10.19): a fit whose rms error is unknown (NaN, e.g. a hand-built fit) exported "rms_error_Ohm": NaN, which strict JSON parsers reject, and a non-finite sample did the same; every non-finite number of a BusType document is now null, save_bustype_json serialises with allow_nan=False, the export refuses a voltage_level that is not finite, and fit_quality_summary reports an unknown rms error as rms=unknown. Tests: tests/test_io_groundinsight.py::test_unknown_fit_quality_and_samples_are_written_as_null, tests/test_io_groundinsight.py::test_export_refuses_a_voltage_level_that_is_not_finite.

Stream fix2gen: Fixes from the second adversarial audit: generators and OSM ingest

Added

  • Outline width of a footprint (audit A2G-06): BuildingFootprint.mean_width_m() (twice the area over the perimeter, the width of a thin rectangle), BuildingFootprint.is_degenerate(), groundfield.geo.mean_width and groundfield.geo.MIN_OUTLINE_WIDTH_M (1 mm). Test: tests/test_geo_footprint.py::test_mean_width_of_an_outline.
  • groundfield.geo.MAX_PAYLOAD_DEPTH (16): deepest container nesting of an accepted Overpass payload (an Overpass result has 7 levels). Test: tests/test_overpass_ingest.py::test_payload_nested_deeper_than_an_overpass_result_is_rejected.

Changed

  • ⚠ Owners of generated mesh foundations (10.12, 10.39; audit A2G-04): the image family solves one uniform leakage current per electrode (an owner). A mesh foundation (cross-braces) is now one owner per wire line at every orientation, bare or encased, for both concrete_model values; an axis-aligned bare one was one grid_mesh owner. One owner over perimeter and braces was +1.6 / +2.5 / +3.2 % high for 2 × 2 / 3 × 3 / 4 × 4 meshes against the equipotential reference (one owner per segment, equal to mom), one owner per wire is +0.3 / +0.5 / +0.6 %. A "distributed" ring foundation is one owner per side also without a shell (it was one owner when bare and axis-aligned). Numbers move: bare axis-aligned mesh foundations −1.2 % (10 m, 2 × 2) to −2.5 % (30 m, 4 × 4); generated networks with the default mesh foundations −0.7 to −0.8 % in every node potential and up to 4.7 % in surface potentials; the largest touch voltage over the default house mesh −3.6 % (2.528 → 2.437 V per ampere, reference 2.402); bare distributed rings at most 0.06 % up to aspect ratio 4 (0.24 % at 10). A "lumped" ring keeps one grid_mesh owner when axis-aligned and one owner per side when rotated (0.24 % apart at aspect ratio 10), and polygon outlines stay one closed wire: one closed polyline would drop the interior sample of the default touch-voltage envelope, which decides it for rings of 20 m and more. AP1 (lumped polygon foundations) does not move. For a mesh foundation, electrode_currents[<anchor>] and grounding_impedance(<anchor>) now refer to its first wire, as for every rotated foundation: use cluster_impedance or the sum over <name> and <name>_w<j>. Golden cases: gen_tn_default, gen_layout_builder, gen_tn_measurement_overhead_leads.
  • ⚠ PEN cables of TnNetworkGenerator form a nearest-point tree (10.38; stream DOC-B): every cable starts at the point of the network already built nearest to its far end, inside a cable at a leakage-free tap junction (pen_tap_<k>, a plan junction): cabinet cables in the order of their distance from the substation (collinear cabinets are chained), service drops from the cable path that feeds their cabinet or radial-trunk tap (or from a drop already routed for it, closer buildings first); a building whose connection point lies on a cable splits it and gets no drop. Service drops started at their cabinet before, 60 to 160 m back along the main in the default network, and now tap the main beside each house (5 m). Numbers move for every generated TN network: default network substation potential −2.1 %, substation leakage −3.1 to −4.8 %, house potentials −0.2 to +1.0 % (the houses are tied closer to the substation); measurement network −1.1 %. Main sections are named <cable>_s<k>. Golden cases: gen_tn_default, gen_tn_measurement_overhead_leads.
  • Overpass ids and levels: element ids and member refs must be 64-bit integers (OverpassError otherwise); a non-finite or negative building:levels tag gives levels=None; outlines without area are skipped (see Fixed).

Fixed

  • A shell that is electrically absent moved a mesh foundation (10.12; audit A2G-04): with ρ_c = ρ_soil (or a 0.1 mm shell) the default 10 × 10 m mesh foundation lost 1.27 % of its impedance and its largest touch voltage on the offset curve dropped from 232.26 to 221.21 V (100 A), because the shell switched it from one owner to one per wire; a distributed 20 × 2 m ring moved by 0.24 %. Tests: tests/test_foundation_owners.py::test_vanishing_shell_on_a_mesh_foundation_is_continuous, ::test_vanishing_shell_on_a_distributed_ring_is_continuous.
  • Mesh foundation impedance depended on the orientation (10.39; audit A2G-04): the same bare mesh gave 4.79618 Ω at 0° and 4.73771 Ω at 30° (100 Ω·m, line kernel). Tests: tests/test_foundation_owners.py::test_mesh_foundation_does_not_depend_on_its_orientation, ::test_distributed_ring_does_not_depend_on_its_orientation, ::test_mesh_foundation_is_close_to_the_equipotential_reference.
  • Untrusted Overpass JSON raised other exceptions than OverpassError (10.05; audit A2G-05): a body nested deeper than the decoder's limit (about 10 000 levels) raised RecursionError, also from a cache file; an unknown key nested 1 500 levels decoded, passed every check and crashed the cache write (json.dump recurses in Python); a 400-digit integer coordinate raised OverflowError; "id": null crashed the parser with TypeError. Tests: tests/test_overpass_ingest.py::test_deeply_nested_body_raises_overpass_error, ::test_payload_nested_deeper_than_an_overpass_result_is_rejected, ::test_deeply_nested_cache_file_is_refetched, ::test_vertex_with_a_huge_integer_coordinate_raises_overpass_error, ::test_huge_integer_coordinate_in_the_json_text_raises_overpass_error, ::test_ids_beyond_64_bits_are_rejected, ::test_element_with_a_null_id_is_parsed_without_an_id, ::test_non_finite_or_negative_levels_are_unknown.
  • Outlines without area (10.05, 10.54; audit A2G-06): parse_overpass_payload kept outlines of identical or collinear vertices with the default min_area_m2=0 (although documented as skipped); their oriented bounding rectangle raised IndexError, so LvNetworkLayout.to_world and TnNetworkGenerator crashed instead of widening the foundation to MIN_FOUNDATION_SIDE_M. The parser now skips outlines narrower than 1 mm on average; the bounding rectangle of such an outline is its covering segment, which the generators widen with a warning. Tests: tests/test_overpass_ingest.py::test_outline_without_area_is_skipped, ::test_thin_but_real_outline_is_kept, tests/test_geo_footprint.py::test_ombr_of_a_degenerate_outline_is_its_segment, tests/test_footprint_foundations.py::test_a_footprint_without_area_gets_a_minimum_foundation, ::test_tn_generator_widens_a_footprint_without_area.
  • Generator objects pickled by v0.15.0 (10.69; audit A2G-07): a pickled TnNetworkConfig unpickled and then failed in build() with AttributeError (renamed fields of soil specs, cabinets, PEN topology and the config itself). Pickles are now upgraded like JSON input: renamed fields and values, defaults for fields added since, and instances of the deprecated aliases (KvsConfig, StarKvsTopology, KvsPlacement, OrtsnetzLayout) load as the current classes, equal to the same object loaded from its v0.15.0 JSON. Tests: tests/test_generator_pickles.py.
  • Overlapping PEN cables made an inductive network non-passive (10.38; stream DOC-B): in a 2-house network both service drops ran from the cabinet 180 m out back along the PEN main (Im Z_in = −0.633 Ω at 1 kHz with inductance_model="neumann"); now +0.072 / +0.055 / +0.051 Ω (perfect mirror / Sommerfeld / Carson series). Tests: tests/test_pen_routing.py.
  • Integer fields of a resolved config held floats (10.53; stream DOC-B): GeneratorConfig.sample stored the float draw of a distribution in building_counts and CabinetConfig.fixed_count, and model_dump_json warned; a draw for an integer field is now int(round(x)), the value the generators build with. Test: tests/test_generators_base.py::test_resolved_integer_fields_hold_integers.

Stream fix3solver: Fixes from the third adversarial audit: solver

Added

  • groundfield.solver.InterfaceContactWarning and the diagnose() category interface_contact (10.32, audit A3S-05): a rod head or tip within one wire radius of a layer interface. The thin-wire model has no end face: a rod that ends exactly at the interface is a wire on one side of it, one that reaches past it by a fraction of its radius touches the other layer through a short piece only, while the solid rod is continuous in between. Against an axisymmetric finite-volume model of the solid rod (4.5 m, a = 8 mm, 1000/30 Ω·m) the line kernel reads +3.3 / +3.9 / +7.2 / +21.4 % with the tip 16 / 8 / 1 / 0 mm above the interface and −4.6 / −1.2 / +0.7 / +2.1 % 1 / 4 / 8 / 16 mm past it (point kernel and mom alike). The step at zero penetration that an earlier entry of this release called the onset of the contact is this limit of the model. No end-face term: the solid rod's 161.4 Ω at the interface lies between the two branches of the thin wire (196 Ω above, at most 149.2 Ω past it). Tests: tests/test_interface_slivers.py::test_rod_tip_within_one_wire_radius_of_the_interface_warns, ::test_rod_head_within_one_wire_radius_of_the_interface_warns, tests/test_diagnostics_report.py::test_diagnose_reports_a_rod_end_at_the_interface.
  • min_distance of two_layer_real_space_kernel, two_layer_layered_correction_real_space and two_layer_layered_correction_group (audit A3S-01): the regularisation length of the closed-form 1/R terms in m; they are clamped at min(1/lambda_clamp, min_distance) instead of 1/lambda_clamp (h_1/200 near the interface). None (default) keeps the clamp; every value at or beyond it is bit-identical. Test: tests/test_cross_layer_line_kernel.py::test_min_distance_leaves_every_farther_image_bit_for_bit.
  • groundfield.world.RESERVED_NAME_PREFIXES ("__layer_", "__cond_"), see Fixed.

Fixed

  • ⚠ Cross-layer diagonal at the interface (10.28, 10.32, audit A3S-01): the diagonal of a segment is the layered correction at the wire radius with the interface image exchanged for its Galerkin integral, but the correction clamped its closed-form 1/R terms at h_1/200 (25 mm for h_1 = 5 m), so every piece within h_1/400 of an interface lost 68–84 % of its layered correction. A ring (r = 3 m, a = 5 mm) at h_1 = 5 m read −5.29 Ω with the default engine (1000/30 Ω·m; 322 Ω instead of 6.80 Ω in 30/1000 Ω·m), and the contact values of a rod tip just past the interface were 10–32 % low in every segment backend. The solver now evaluates the diagonal at the wire radius and pairs closer than h_1/200 at the 1 mm of its point forms (also mom_sommerfeld's two-layer off-diagonal kernel and two_layer_probe_matrix, which clamps at its own min_distance). The diagonal equals the image solution to 1e-13; the ring is continuous through h_1 (4.1826 Ω 1 µm above, 4.1805 Ω at h_1). Numbers move for a rod tip or head within h_1/400 of an interface (12.5 mm for h_1 = 5 m, 75 mm for 30 m; 4.5 m rod, a = 8 mm, 1000/30 Ω·m, tip 1 µm past h_1: 133.5 → 149.2 Ω, +11.7 %; 10000/10 Ω·m: 123.2 → 180.7 Ω; against the solid rod −4.6 / −1.2 / +0.7 % at 1 / 4 / 8 mm, before −14.6 / −10.7 / −6.8 %), for horizontal wires at or within h_1/400 below an interface, and for pairs of segments closer than h_1/200 (segment lengths below about h_1/100 near the interface: a 2 m rod through h_1 = 30 m, ds = 0.05 m, line kernel −0.014 %). Not affected: AP1 (station rods end 0.2 m or more above h_1). Golden cases: none. Tests: tests/test_cross_layer_line_kernel.py (::test_ring_resistance_is_continuous_through_a_deep_interface, ::test_diagonal_correction_at_the_wire_radius_matches_the_image_solution, ::test_pairs_closer_than_the_clamp_match_the_image_solution), tests/test_interface_slivers.py::test_rod_tip_contact_against_the_solid_rod_reference, ::test_rod_head_contact_against_the_solid_rod_reference, ::test_rod_tip_contact_does_not_depend_on_the_interface_clamp.
  • Point form above the interface (10.28, audit A3S-02): the point-form guard of audit round 2 ran only when a segment reaches h_1. With every wire above h_1 the point form takes the image of a segment in the interface as a point source 2(h_1 − z) away: a ring (r = 3 m, ds = 0.5 m) 1 µm / 1 mm / 1 cm / 5 cm above h_1 = 5 m read −1931 / −945 / −57.9 / 21.2 Ω (line kernel 4.18 / 4.77 / 15.4 / 28.0 Ω) with kernel="point", mom, mom_sommerfeld (two and three layers) and solve_mutual_*, also in 0.15.0; +853 % … +0.1 % in 30/1000 Ω·m. The guard now applies on both sides of the interface with the same thresholds: a horizontal wire closer than 0.387 segment lengths raises BackendCapabilityError, one within 0.6 warns with PointKernelInterfaceWarning (−2.5 % / −0.4 % at 0.2 m above h_1). Above the interface this error threshold is conservative: it also refuses coarse but accurate models (a ring r = 25 m 1.2 m above h_1 with 5 m segments, +0.9 % against the line kernel), which a finer segment_length — the message names one — or the line kernel solves. The default line kernel is unaffected. Tests: tests/test_cross_layer_point_form.py::test_point_form_rejects_a_horizontal_wire_just_above_the_interface, ::test_point_form_warns_for_a_horizontal_wire_above_the_interface, ::test_mutual_matrix_point_form_is_guarded_above_the_interface, ::test_rods_ending_just_above_the_interface_are_not_refused.
  • Reserved name prefixes (10.66, audit A3S-03): an electrode called __layer_r__L1 next to a rod r through h_1, or __cond_pen__seg_0 next to a galvanic conductor pen, took the place of the solver's internal owner or node of that name and the solve failed with numpy.linalg.LinAlgError. add_electrode, add_junction and World.check() (every solve, worlds loaded from JSON) reject node names with the prefixes __layer_ and __cond_. Tests: tests/test_source_validation.py::test_check_rejects_a_name_with_a_reserved_prefix, ::test_reserved_prefixes_are_rejected_when_a_node_is_added.
  • ⚠ Field of a soil of one resistivity declared as layers (10.48, audit A3S-04): TwoLayerSoil(rho, rho, h) solved like homogeneous soil, but FieldResult.potential and solve_mutual_field evaluated sources below h with the point form of the two-layer kernel instead of the line sources of the homogeneous result: +2.7 % at (0.2, 0, 4) m next to a 0.3–6.3 m rod, 21 % at 5 cm from it. Both now read the canonical layer stack and equal the homogeneous result bit for bit; a stored MultiLayerSoil with at most two distinct layers is evaluated as two-layer soil (it raised NotImplementedError for three declared layers). Who is affected: field values of equal-resistivity layered declarations near wires below h. fem keeps the declared interface in its mesh on purpose (mesh topology continuous over a ρ₂ sweep): 1.7e-6 / 1.0e-5 from the homogeneous solve for two / three equal layers. Golden cases: none. Tests: tests/test_layer_stack.py::test_field_of_an_equal_resistivity_stack_is_the_homogeneous_field, ::test_potential_of_a_stored_three_layer_declaration_with_two_distinct_layers.
  • Building large networks (audit round 3, generator note): since generated mesh foundations are one electrode per wire line, TnNetworkGenerator.build() was 10–80 times slower for 100–1000 houses: World.add_* scanned every list for the new name. A name index next to the world (not part of the model: equality, copies, pickles and JSON are unchanged) makes the check O(1) per add; generated worlds are bit-identical (fingerprints for 100 / 400 / 1000 houses). 1000 houses: 6.97 → 2.44 s (star) and 7.52 → 2.65 s (radial) on the measuring machine. Tests: tests/test_world_names.py::test_each_add_costs_constant_name_work, ::test_lists_edited_by_hand_are_seen_by_the_next_add, ::test_the_index_is_no_state_of_the_world.
  • Quoted near-field deviations (10.21, 10.22): UniformCurrentFieldWarning, the safety module and the known limitations quoted "+19 % / −21 %" (touch / step 1 m outside a 20 m grid corner), the point-kernel numbers, and the image engine page −28 % for a step that starts above the corner. They now give the default (line) kernel and the step: touch 1 m outside +20 %, step from 1 m to 2 m outside −21 %, from the point above the corner 1 m outwards −28 % (point kernel +19 / −21 / −28 %). The interior docstring of touch_voltage_envelope called a generated foundation a grid_mesh; it is a group of bonded wires whose cells the default samples. Tests: tests/test_touch_voltage_footprint.py::test_the_quoted_corner_deviations_are_those_of_the_default_kernel, tests/test_touch_voltage_envelope.py::test_a_generated_mesh_foundation_is_sampled_in_its_cells_by_default.

Stream fix3coup: Fixes from the third adversarial audit: coupling

Fixed

  • ⚠ Wires lying beside each other: order-free, pointwise rule (10.46, audit A3C-1, A3C-2): the touching-wire rule of audit round 2 switched a whole near-parallel pair to touching wires when the partner's end points lay inside a cylinder of radius r_a + r_b around the row segment, so the result depended on the order of the conductors: a V pair of 1 m and 0.5 m at 1.5° read 0.362 or 0.503 µH (+38.7 %), the generator's in-line fall-of-potential setup with lumped leads read Im Z_meas(50 Hz) = 0.134442 or 0.126676 Ω (perfect_mirror) depending on whether the feed or the probe lead came first. Tilted V and X pairs whose far ends lay just outside the cylinder kept a filament value above the self inductance: an indefinite inductance matrix (minimum eigenvalue −1.3e-8 H), a two-wire loop with Im Z_in(1 kHz) = −0.14 mΩ (−0.51 mΩ with the skin model). The rule now acts pointwise inside the Neumann integral: where a point of one wire lies beside the other wire (its foot on the other axis falls inside that wire) closer than r_a + r_b, that distance is used; both one-sided integrals (inner integral in closed form) are averaged on end points in a fixed order — bit-identical for every order and direction of the segments, continuous in the geometry, 4e-15 against an independent mpmath quadrature. The in-line reading is 0.126676 Ω in both orders (5 m lead segments: 0.126683 Ω); 2000 random close configurations × 6 conventions gave no indefinite matrix (round-2 state: 700). Numbers move for pairs that lie beside each other closer than touching except exactly coincident ones: partly overlapping parallel wires (+2.3e-4 for a 2 mm offset against the whole-pair value), V pairs leaving a junction at an acute angle, wires crossing at one depth, branches starting on another segment (crossing at 30° with r = 0.1 mm: −7.9e-5). Chain neighbours, bends turning by less than 90° and pairs farther apart keep their values bit for bit. Golden cases: none (all bit-identical). Tests: tests/test_interpenetrating_wires.py::test_beside_rule_does_not_depend_on_the_order_or_direction, ::test_beside_rule_matches_an_independent_quadrature, ::test_matrix_does_not_depend_on_the_order_of_the_conductors, ::test_inline_reading_does_not_depend_on_the_order_of_the_leads, ::test_partial_inductance_matrix_stays_positive_definite, ::test_random_close_configurations_are_positive_definite, ::test_two_wire_loop_has_a_positive_reactance, ::test_mutual_is_continuous_across_the_touching_distance, ::test_chain_neighbours_and_bends_keep_their_closed_forms.
  • ⚠ A wire inside another (10.46, audit A3C-5): a core on the axis of a cable shield was coupled like two wires touching on the outside (axis distance r_c + r_s): loop inductance +36 % against the geometric mean distance, +61 % against the analytic coax, silently. Where the thinner wire runs inside the thicker one, the thicker radius is used — a filament inside a thin tube couples to it as at the tube radius: with the internal inductance on the core only, the loop of a 100 m core (5 mm) in a shield (15 mm) is 26.966 µH against the analytic coax 26.972 µH. Equal radii never count as one wire inside the other (cables in one trench drawn on one axis stay touching wires); for unequal radii the value steps where the thinner axis leaves the thicker wire (concentric cable vs two cables side by side). Golden cases: none. Tests: tests/test_interpenetrating_wires.py::test_wire_inside_another_couples_at_the_radius_of_the_thicker_wire, ::test_wire_inside_another_uses_the_geometric_mean_distance, ::test_coincident_wires_of_equal_radius_stay_touching_wires.
  • ⚠ carson_series: segment order of near-parallel pairs (10.20, audit round 3, evidence e13): a near-parallel pair that is not exactly parallel was projected on the axis of its first segment, so reversing the segment order moved entries of the correction by up to 3.1 % of the largest one (a pair got an overlap in one order and none in the other). Such pairs are now projected on the bisector of the two axes from the mean of their mid-points (3e-17 after reversal); exactly parallel pairs keep their numbers bit for bit. Numbers move for carson_series worlds with horizontal conductors at small angles to each other: the mutual impedance of two 300 m or 1 km leads 2 m apart grows by 2e-5 at 0.5°, 4e-4 at 2°, 1.6e-3 at 4° and up to 6.4e-3 at 8° (50 Hz and 1 kHz); the step at the 8.1° boundary becomes 12.8 % for the 1 km leads at 1 kHz (12.3 %). Golden cases: none. Test: tests/test_carson_validity_domain.py::test_carson_tiling_does_not_depend_on_the_segment_order.
  • ⚠ Filaments at tiny angles (10.46, audit A3C-4): two filaments from one vertex below the coaxial tolerance (4.5e-5 rad) were taken as overlapping coaxial filaments and fell to the 16 × 16 rule: 16 % off at 1.5e-6 rad, 3.8 % at 1e-5 rad; just above it the vertex formula lost 2.7e-9. Below 0.81° the vertex formula is evaluated without cancellation: round-off on axis-parallel geometry, at most 4e-10 in a general orientation. Filaments crossing at tiny angles lost the crossing-point mark of the close-pair rule (computed from 1 − cos², cut off at 1e-14): 9.5e-4 at 1e-8 rad; below 1 − cos² = 1e-6 the mark now comes from a cross product: 1.0e-9 at 1e-8 … 3e-8 rad, 5e-11 from 1e-6 rad on. Numbers move for filaments (neumann_mutual) and segment pairs at such angles that are farther apart than r_a + r_b. Golden cases: none. Tests: tests/test_neumann_touching.py::test_filaments_from_one_vertex_at_tiny_angles, tests/test_neumann_close_pairs.py::test_crossing_filaments_at_tiny_angles.
  • Accuracy statements say where they hold (10.24, 10.46, 10.20, audit A3C-4): measured worst cases replace statements that held only where they were measured. Sommerfeld correction of a long segment (composite rule above a quarter skin depth; audit round 2 stated 7e-5 / 1e-6 and "lumped conductors match their chains to 1e-4" from buried cases): against a refined rule, 50 Hz and 1 kHz, up to 3 km, within 5.9e-4 in the earth-return resistance and 2.4e-4 in the reactance (worst: a 3 km overhead line at 10 m over 10 Ω·m at 1 kHz; a 1 km one 4.8e-4 / 1.2e-4; buried in 100 Ω·m 1.7e-4), tabulated 3.3e-4 / 9.6e-5; the historic rule below a quarter skin depth reaches 4.8e-4, so the correction steps by 3.5e-4 (resistance) at L = δ/4. Close pairs (stated "5e-11"): 5e-11 above 1e-6 rad, 1.0e-9 at 1e-8 rad; pairs inside the parallel tolerance use the parallel closed form at the start offset (4.2e-9 for wires 1 cm apart tilted by 1e-10 rad, 1.7e-5 at 1 µm). Overhead wire over a buried one (stated "1e-9"): 4.2e-9 up to x = 300 m (1 kHz, 10 Ω·m; 1e-10 at 50 Hz), 1.2e-7 at x = 1 km, inherited from Carson's J (1.2e-7 at a = 28, θ = 89.9°, QUADPACK's Fourier rule). Tests: tests/test_sommerfeld_long_segments.py::test_long_segment_rule_meets_its_stated_accuracy, ::test_the_step_at_a_quarter_skin_depth_is_the_stated_one, tests/test_neumann_close_pairs.py::test_crossing_filaments_at_tiny_angles.
  • carson_series validity domain in the documentation (10.20, audit A3C-3): the explanation page and the how-to still described the correction as "scaled by the geometric length of each segment pair" (the heuristic removed in audit round 2). They now describe the per-metre tiling of near-parallel horizontal pairs, the transmitted field across the surface, the Sommerfeld fallback with its step at 8.1°, the long-segment rule and the rule for wires beside each other; ADR-0004, -0005 and -0006 carry the corrections in their 2026.11 amendments. Test: tests/test_carson_validity_domain.py::test_docs_describe_the_carson_validity_domain.

Stream fix3gen: Fixes from the third adversarial audit: generators and export

Added

  • groundfield.io.groundinsight.MAX_METADATA_DEPTH (32): deepest nesting of objects and lists in the metadata of a BusType document (the exporters write four levels); a deeper document is refused on load. Test: tests/test_io_groundinsight.py::test_crafted_bustype_documents_raise_value_error.

Changed

  • ⚠ PEN cables of TnNetworkGenerator (10.38; stream DOC-B; audit A3SG-01, A3SG-02, A3SG-03): every cable cabinet has its own cable, as the topology documents (star: a straight cable from the substation; radial trunk: one cable per trunk segment); cabinets on one line get separate cables in one trench. A service drop taps the cable path that feeds its own building — the cable of its cabinet, or the trunk from the substation to its tap source — at the point nearest to the building's connection point: a leakage-free tap junction pen_tap_<k> that splits the cable into sections <cable>_s<k>, or the substation / the cabinet at the end of the cable; a building in a substation slot of the radial trunk is connected to the substation. What the router guarantees: a drop never starts on another building's drop and never runs along the cable it taps; no cable section or drop is shorter than 1 cm (a tap closer to a node is that node; longer for PEN radii above 7.3 mm, so that every section keeps twice the resistance below which a distributed conductor is refused); a building whose connection point lies on its feeding cable splits it (no drop); two nodes closer than that raise ValueError. A drop may share its route with another cable (another cabinet's cable, a trunk, another drop), as cables in one trench do; the inductive coupling treats such conductors as touching wires and the networks stay passive. Against 0.15.0, where every drop ran from its cabinet (60 to 160 m back along the main in the default network, coaxial with it): the routing moves the golden networks (one cabinet west of every house) by −2.1 % in the substation potential, −3.1 to −4.8 % in the substation leakage, −0.2 to +1.0 % in the house potentials and −1.1 % in the measurement network; the input impedance of default-grid networks with ring foundations (image backend, 50 Hz, 100 Ω·m) moves by −6.4 / −1.1 / −0.2 % for 30 / 100 / 200 houses (star) and 0.0 / −0.1 % for 30 / 100 houses (radial trunk). Against the nearest-point tree of the first 2026.11 draft (chained cabinets, drops hung on drops): golden networks bit-identical; 30 / 100 / 200 houses −4.1 / −2.9 / −2.7 % (ring foundations) and −2.4 / −3.4 / −2.8 % (default mesh foundations), radial trunk −0.5 / −0.3 %. Golden cases: gen_tn_default, gen_tn_measurement_overhead_leads (moves declared in fix2gen.toml).
  • Polygon foundations of thin outlines (10.54; audit A3SG-07): with foundation_outline="polygon" an outline whose oriented bounding rectangle is narrower than MIN_FOUNDATION_SIDE_M (1 m) is replaced by that rectangle widened to 1 m, with the same UserWarning as for "ombr" (a ring along an outline 0.5 to 1 m wide ran along both faces of a wall). Outlines wider than 1 m on average are unchanged.
  • TnNetworkGenerator.build() of large networks (no finding): the materialiser hands objects instead of names to the world, so bonds and PEN sections need no search through the world: 1000 default houses 6.5 → 4.4 s (star) and 7.3 → 5.4 s (radial trunk), worlds byte-identical. The rest of the cost is the name checks of World.add_electrode / add_conductor, linear in the size of the world.

Fixed

  • build() failed for 1–3 % of random TN networks (10.38; audit A3SG-01): a service drop whose tap fell 0.1 µm to 4.7 mm from a node of the cable left a section that the Conductor model refuses (series resistance below 1e-6 Ω), so build() raised pydantic.ValidationError (1 of 100 random 60-house and 2 of 60 random 200-house networks). The layout builder had the same defect for taps a few millimetres from a cable corner or from another tap; it now merges cable nodes closer than the shortest section and refuses a cable between two sites closer than it with ValueError. Tests: tests/test_pen_routing.py::test_a_building_millimetres_beside_a_node_still_builds, ::test_a_tap_millimetres_from_an_earlier_tap_snaps_to_it, ::test_random_position_network_builds, ::test_taps_on_a_thick_pen_keep_sections_the_conductor_model_accepts, ::test_random_networks_build_and_route_as_documented (400 random networks, 60 / 200 houses, both topologies), tests/test_lv_network_layout.py::test_taps_millimetres_apart_share_one_node, ::test_a_tap_millimetres_from_a_cable_corner_is_the_corner, ::test_a_cable_between_two_sites_closer_than_a_section_is_rejected.
  • Cabinets chained on one cable, drops hung on other drops (10.38; audit A3SG-02, A3SG-03): the nearest-point tree of the first 2026.11 draft fed a cabinet from the cable of a nearer one, although StarCabinetTopology and TnNetworkConfig.pen_topology document a direct cable per cabinet (input impedance +1.8 / +2.6 % for 100 / 200 houses against the 0.15.0 routing, against the documented direction), and started most drops on other houses' drops (26 of 30 in the radial default grid with ring foundations, 19 of 30 in the default star network). Tests: tests/test_pen_routing.py::test_star_topology_wires_every_cabinet_directly_to_the_substation, ::test_collinear_cabinets_have_separate_cables_in_one_trench, ::test_z_in_of_a_100_house_network_drops_against_the_old_routing, ::test_a_drop_taps_the_cable_of_its_own_cabinet, ::test_no_drop_starts_on_another_drop_in_the_radial_default_grid, ::test_overlapping_drops_and_trunks_stay_passive, ::test_routing_guarantees.
  • A loaded BusType document crashed the other entry points (10.01; audit A3SG-04): load_bustype_json accepted documents for which fit_quality_summary raised AttributeError, TypeError, ValueError or OverflowError (fit_quality null or a list; a figure that is an object, a list, a string or a 400-digit integer), to_dict() raised RecursionError (metadata nested 3 000 levels, which the JSON decoder reads) or wrote a NaN description (not strict JSON). The loader now refuses a name or system_type that is an object or a list, a description that is neither a string nor null, an impedance_formula that is an object or a list (EvaluateSpecError) and metadata deeper than MAX_METADATA_DEPTH; to_dict() writes a non-string description as null and walks the metadata without recursion; fit_quality_summary reads only finite numbers and strings. Tests: tests/test_io_groundinsight.py::test_crafted_bustype_documents_raise_value_error, ::test_a_loaded_document_never_crashes_the_other_entry_points, ::test_fit_quality_summary_reads_the_figures_it_can, ::test_to_dict_of_a_spec_built_in_memory_is_strict_json_or_refused.
  • A sum with an exact small imaginary part parsed to zero (10.01; audit A3SG-05): the formula parser drops a collected sum that cancels within its 128-bit working precision, but compared the complex magnitude of the sum with its largest term: (1 + 1e-31*j - 1)*1e31*f evaluated to 0 instead of 50j at 50 Hz. Real and imaginary parts are now judged separately; the 119 accepted formulas of the corpus evaluate as before (worst 1.9e-15 against a 60-digit mpmath evaluation). Test: tests/test_formula_security.py::test_real_and_imaginary_parts_of_a_sum_cancel_separately.
  • Polygon foundations of outlines narrower than 0.5 m (10.54; audit A3SG-07): LvNetworkLayout.to_world(foundation_outline="polygon") raised ValueError ("polygon collapses ... after removing sub-centimetre edges", although the edge limit is 0.5 m) for every such outline the Overpass parser keeps; it is widened now (see Changed), and the materialiser's last check names the real limit. Tests: tests/test_footprint_foundations.py::test_a_thin_outline_with_a_polygon_foundation_is_widened, ::test_a_polygon_foundation_of_an_ordinary_outline_is_unchanged, ::test_a_collapsing_polygon_outline_names_the_real_edge_limit.
  • Margin of generated mesh foundations against mom (10.39; audit A3SG-06): the documentation said one current per wire is +0.3 / +0.5 / +0.6 % "against mom"; that is the line kernel against a line-kernel per-segment reference. Against mom (point kernel) the default line kernel is +1.1 % and kernel="point" +0.3 … +0.5 % for 10 m 2 × 2 to 30 m 4 × 4 meshes; one current for the whole mesh was +2.4 … +3.7 % (point kernel +1.5 … +3.1 %). Test: tests/test_foundation_owners.py::test_documented_margin_of_mesh_foundations_against_mom.

Stream dsafety: User decisions Q3 and Q4: touch points, EN 50522 beyond 10 s

Added

  • Touch points: touch_voltage_at_part (10.21; user decision Q3): the EN 50522 touch voltage of an accessible metal part above ground — a station housing or its door, a mast, a fence post, a cable cabinet, a service connection box. The part is given by its horizontal position and the electrode or junction it is bonded to (bonded_to=), whose potential it carries; a part bonded to a PEN junction expresses a transferred potential. The feet stand on the circle of radius distance (1 m) around the part (n_angles, default 24), optionally only in given directions, and the positions inside the outlines in exclude (the housing or the building, where nobody can stand) are dropped. Returns the touch-voltage phasors and azimuths per foot position like touch_voltage_envelope (and the positions with return_points=True). Available as gf.touch_voltage_at_part and gf.safety.touch_voltage_at_part. A service connection box 40 m from a ring earth (100 A, 100 Ω·m), bonded to the PEN, has 1081 V of the 1121 V earth potential rise as touch voltage. Tests: tests/test_touch_voltage_at_part.py::test_part_on_a_wire_matches_touch_voltage_on_the_offset_curve, tests/test_touch_voltage_at_part.py::test_part_at_a_rod_head_against_the_analytic_surface_potential, tests/test_touch_voltage_at_part.py::test_part_bonded_to_a_pen_junction_carries_the_transferred_potential.
  • How-to "Assess touch voltages" (docs/how-to/assess-touch-voltages.md): touch points of a compact station, the transferred potential over the PEN, the meshes of an open-air grid, and the comparison with the permissible values; tutorial T08 adds a fence bonded to the substation grid (199.5 V at the corner post against 140.7 V 1 m outside the grid, mom, 150 A) and an earth fault that is not cleared.

Changed

  • ⚠ touch_voltage_envelope samples no interior by default (10.21; user decision Q3): inside an electrode's footprint stands the station, the house, the steel structure or the mast, so the default is now interior=False for every electrode kind: the curve distance outside the wires only. The mesh sampling of the development snapshots (the centres of the meshes of grids and of generated mesh foundations, the centre of a ring) is the explicit interior="meshes", for open-air grids such as a substation yard; interior=True also samples the inside of a closed polyline. interior=None is rejected with a hint. Against 0.15.0 the default envelope is the footprint's offset curve of 10.21: a ring of 10 m radius at 0.8 m (100 A, 100 Ω·m, image, point kernel) keeps 139.4 V (the development snapshots gave 182.6 V, its centre; with the default line kernel 142.2 / 185.5 V), a 20 m perimeter loop (1 × 1 grid) 141.4 V instead of 158.3 V in its centre, and the 20 m × 20 m grid with 4 × 4 meshes 111.4 V (unchanged: the maximum is 1 m outside a corner, the mesh centres reach 63.0 V). Affected: envelopes of rings, grids and generated foundations computed with the development snapshots; pass interior="meshes" for open-air grids. Golden cases: none (no case evaluates the envelope). Tests: tests/test_touch_voltage_envelope.py::test_envelope_samples_no_interior_by_default, tests/test_touch_voltage_envelope.py::test_release_note_envelopes_with_the_new_default.
  • ⚠ EN 50522 permissible touch voltage beyond 10 s (10.42; user decision Q4): permissible_touch_voltage_en50522(t_f) follows Figure 8 / Table B.4 of EN 50522:2022 up to 10 s and returns 80 V for every t_f > 10 s, including math.inf for an earth fault that is not cleared (resonant-earthed networks). The curve of Figure 8 ends at 10 s; the note to Figure 8 (5.4.1) and the text after Table B.4 (B.3) allow 80 V for current-flow durations considerably longer than 10 s, below the 85 V end value of the table. 0.15.0 returned 85 V beyond 10 s (now −5.9 %) and rejected math.inf. permissible_prospective_touch_voltage_en50522 uses the same U_Tp: beyond 10 s 80 V + 50 mA · R_A / HF (1000 Ω shoes on 100 Ω·m soil: 137.5 V instead of 142.5 V). Affected: assessments with fault durations above 10 s, e.g. resonant-earthed networks. Golden cases: none (safety_en50522_curve covers 0.05 … 10 s). Tests: tests/test_safety.py::test_en50522_beyond_ten_seconds_is_80_volt, tests/test_safety.py::test_prospective_touch_voltage_beyond_ten_seconds_uses_80_volt.

Removed

  • long_duration= of permissible_touch_voltage_en50522 and permissible_prospective_touch_voltage_en50522 (added during this release cycle, never released): 80 V beyond 10 s is the default. Test: tests/test_safety.py::test_en50522_has_no_long_duration_keyword.

Deprecated

  • Nothing.

Stream drhoeff: User decision Q6: effective resistivity

Added

  • effective_resistivity (10.84, user decision Q6): the effective resistivity of a homogeneous or two-layer soil in Ω·m, ρ_eff = ρ₁^(1−w) · ρ₂^w with w = w0 · (h₁ / h_ref)^(−β), h_ref = 10 m and the AP1 calibration w0 = 0.13, β = 0.8 (group-specific values as w0=, beta=, h_ref=). gf.effective_resistivity(soil) (also groundfield.soil.effective_resistivity, or with the keywords rho_1, rho_2, h_1) returns ρ itself for homogeneous soil and for stacks of equal layers, without round-off (the plain formula gives 200.00000000000003 Ω·m for 200 / 200 Ω·m, h₁ = 10 m); reduces a MultiLayerSoil to its canonical stack (equal adjacent layers merged, as the layered backends do, 10.48) and raises ValueError for three or more distinct layers; limits w to [0, 1], so ρ_eff stays between ρ₁ and ρ₂ (the unlimited formula leaves that interval below h₁ = 0.78 m: 17.9 Ω·m for 100 / 30 Ω·m at h₁ = 0.5 m; with the limit such a thin upper layer gives ρ₂). Inside the calibration range of the AP1 catalogue (h₁ = 5 … 30 m, ρ₁ = 30 … 1000 Ω·m, ρ₂ = 30 … 200 Ω·m) the value is bit-identical to the AP1 / AP2 scripts' r1 ** (1 - w) * r2 ** w and agrees with a 50-digit evaluation to 1.6e-16. Test: tests/test_effective_resistivity.py.

Changed

  • ⚠ The rho of a BusType in layered soil is the effective resistivity (10.84, user decision Q6): rho_at_fit of a vector fit and the rho samples of a standard form fitted in layered soil are ρ_eff of the soil they were computed in, effective_resistivity(soil), the specific_earth_resistance the AP2 network model gives a groundinsight bus. This replaces the upper-layer resistivity ρ₁ that the 10.84 entry of this release cycle had made the convention; on the AP1 grid ρ_eff differs from ρ₁ by −54.8 % (1000 over 30 Ω·m, h₁ = 5 m) to +53.6 % (30 over 200 Ω·m, h₁ = 5 m). The error message for a missing rho_at_fit, the docstrings of the four exporters, the IO and Soil references, ADR-0008 and tutorial T05 state it. Every BusType document records the convention as metadata["rho_definition"] = "effective_resistivity" (documents of 0.15.0 have no such entry). No function computes a different number: the exporter writes the rho it is given. Affected: BusTypes exported in layered soil with ρ₁ as rho. A compact electrode in the upper layer follows ρ₁ more closely than ρ_eff of the AP1 networks: the station of the IO example (2 m ring and 3 m rod) swept over ρ₁ fits the standard form to 13.4 / 8.3 / 3.6 % over ρ_eff and to 3.9 / 1.9 / 0.6 % over ρ₁ for h₁ = 5 / 10 / 30 m; check max_relative. Golden cases: none. Tests: tests/test_io_groundinsight.py::test_rho_at_fit_convention_for_layered_soil_is_the_effective_resistivity, ::test_bustype_metadata_records_the_rho_definition, ::test_layered_soil_exports_pair_with_an_effective_resistivity_bus.

Stream ddefaults: User decisions Q15 to Q17: galerkin, tabulated Sommerfeld, resource limit

Added

  • Per-engine resource limit Engine.max_segments (10.06, user decision Q17): the hard problem-size limit of the segment backends — the number of leakage segments and the number of unknowns of the dense nodal system — is set per engine: Engine(max_segments=...) (also a create_engine parameter) raises or lowers it for one engine, a positive integer; None (default) takes the module constant groundfield.diagnostics.HARD_LIMIT (20 000), read at solve time, so the constants stay the defaults. Every segment backend (the image family, mom, mom_sommerfeld), solve_mutual_matrix and solve_mutual_field refuse a larger world with ResourceLimitError before anything of that size is allocated; check_segment_budget, expected_segments (new key "limit"), check_segment_resolution and diagnose (report.context["max_segments"]) check against the same limit, and the messages name the setting to change. The limit is recorded in the new core metadata key FieldResult.metadata["max_segments"] (the engine block of the provenance keeps the request itself). SOFT_LIMIT (5 000, the size above which the solve reports that it may take minutes) stays a module constant. Tests: tests/test_resource_limit.py.

Changed

  • ⚠ solve_mutual_matrix uses the galerkin off-diagonal for every call (10.34, user decision Q15): offdiag="galerkin" (the reaction of the leakage distributions: reciprocal, and the matrix with which (Y_L + Z_G⁻¹)u = i reproduces the solve of the clusters joined by branches) is the default whatever the call; offdiag="probe" (the potential at one probe point per cluster, the definition of releases up to 0.15.0) stays available. A call that passes probe_points without offdiag="probe" — every 0.15.0 call, the AP1 catalogue pipeline among them — returns the galerkin matrix; the points are ignored, not validated, with the new groundfield.solver.mutual.ProbePointsIgnoredWarning, which names offdiag="probe" as the way back. This supersedes the selection rule added earlier in this release cycle (offdiag=None choosing "probe" when probe points were given; None is no longer accepted). The diagonal does not move. On an AP1-like site (station ring and three rods, twelve polygon foundations, ds = 2 m, five soils) the symmetrised probe matrix missed the input impedance of the joined network by −0.15 … −0.88 % and single off-diagonal entries by up to 41 % (median 0.15 … 1.1 %); the galerkin matrix reproduces it to 7e-13. On the AP1 catalogue path (group-2 site, 7 corner soils × 4 penetrations) |Z_ons| at 50 Hz moves by −0.05 … +0.29 % at penetrations up to 20 % and by +0.25 … +2.67 % at 40 % (largest at ρ₁ = 1000 Ω·m), the ONS current share at 50 Hz by up to +2.7 %. Who is affected: every Z_G built with probe points, the AP1 catalogue. Golden cases: mutual_foundations_lumped_concrete, mutual_foundations_distributed_concrete, mutual_three_rods_crosslayer, line_mutual_two_layer (Z_G norm-wise 7.7e-4 … 8.8e-4, single off-diagonal entries 0.48 … 5.9 %). Tests: tests/test_mutual_matrix.py::test_galerkin_is_the_default_whatever_the_call, ::test_ignored_probe_points_are_not_validated, ::test_offdiag_selection_and_validation.
  • ⚠ Tabulated Sommerfeld assembly by default (10.60, user decision Q16): Engine.sommerfeld_assembly defaults to "tabulated" (one table of the spectral integral per pair of depth groups and frequency); "exact" (one quadrature per segment pair, the default up to 0.15.0) stays available. The image family, mom, mom_sommerfeld and solve_mutual_* follow the setting alike; engine JSON without the field (0.15.0) gets the new default. Blocks of fewer than 64 sub-segment pairs keep the per-pair rule, so small inductive worlds do not move. On a TN network with an inductive PEN (TnNetworkGenerator, homogeneous 100 Ω·m, ds = 1 m, four frequencies 50 … 1000 Hz) the input impedance of the tabulated solve lies within 2e-10 of two independent refined references (per-pair rule with 200 instead of 24 interpolation nodes; tables of 400 instead of 100 nodes; both with a refined λ grid), which agree with each other to 2e-10, while the per-pair rule is 1.2e-8 off (8 houses); CPU time 1.0 s instead of 16.6 s (8 houses, 78 inductive branches) and 12.2 s instead of 306 s (30 houses, 338 inductive branches; input impedance equal to 1.1e-8, the tabulated one 1.8e-11 from the 400-node tables). The correction matrices of small conductor sets in twelve critical geometries (buried, overhead, 1 cm below the surface, in the surface plane, crossing the surface or a layer interface, two- and three-layer earth, 250 m segments, 10 and 1000 Ω·m; 50 Hz and 1 kHz) are finite, symmetric and free of warnings; against a reference refined in S(ρ) and in the λ grid the tabulated rule is closer than the per-pair rule in ten of them (1.5e-7 … 1.1e-5 against 4.2e-6 … 7.6e-5 of the largest entry) and equal in two (the surface plane, where both use the per-pair rule, and a riser through h₁, 4.3e-6). Who is affected: inductive conductors under earth_inductive_model="sommerfeld" (the default) with blocks of at least 64 sub-segment pairs; numbers move by about 1e-8 … 2.4e-6. Golden case: cond_lumped_long_pen_sommerfeld (≤ 2.4e-6; against the refined per-pair reference the tabulated result is 4.2e-7 off, the per-pair rule 2.0e-6). Tests: tests/test_sommerfeld_assembly_default.py.

Decisions on the questions left open (2026-11-08)

After the third adversarial audit and the user's decisions Q1–Q19, the release preparation left 17 questions to the author, each with a recommendation. The author followed every recommendation. The table records the question, the decision and where it went; the work streams d2solver, d2gen and d2soil below implemented the decisions that change code.

Q Question Decision Where
20 Encase the cross-braces of mesh foundation electrodes in the concrete shell, as DIN 18014 lays the foundation earth electrode with its connections in the concrete? yes streams d2gen, f2gen
21 Deprecate FoundationElectrodeSpec.concrete_model, which only chooses one or four current owners of a ring foundation (≤ 0.06 % apart up to aspect ratio 4)? yes; the measured difference is larger (< 1 % / < 2 % up to aspect ratio 4 / 50, see the box below; for the author's review) streams d2gen, f2gen, f3gen
22 Keep the PEN routing of TnNetworkGenerator (an own cable per cabinet, a service drop taps the cable that feeds its building)? Place cabinets per building group in the future? routing kept; cabinets per building group moved into 2026.11.0 (user decision of 2026-11-14, stream w1gen; a wide group's cabinet on the ray through its far-end building since audit W1B-01, stream fw1gen; the 20 m step of the rule stays, user decision D7, stream fw1r2gen) changelog
23 fem whose equivalent hemisphere puts current into a more conductive layer that the electrodes do not touch (−38 … −98 %): error instead of warning? error; extended after the audit to a more conductive layer within the electrodes' horizontal half-extent (coordinator, for the author's review) streams d2solver, f2solver, f3solver
24 Point-form guard near a layer interface: keep the conservative thresholds (warning within 0.6 segment lengths, error within 0.387)? kept known limitations
25 Accept the step of carson_series at the 8.1° boundary of its validity domain as a documented limit? accepted known limitations, earth return
26 Accept that the simulated in-line fall-of-potential reading moves because the leads now couple as wires lying side by side (Im Z_meas 0.063 → 0.054 Ω at 50 Hz)? accepted release notes, 10.46
27 Warn when perfect_mirror couples conductors on opposite sides of the soil surface through its additive image? warning streams d2solver, f2solver, f3solver
28 Count powers of numbers (10**40) in the rule on nested exponents of the formula parser, as groundinsight does? yes; already the rule ((f*10**40)**2 is rejected, tests/test_formula_security.py::test_exponents_of_nested_powers_multiply_to_at_most_max_pow) no change
29 Only document that printing a parsed formula or passing it to lambdify lets SymPy evaluate parts of an untrusted formula again? documented IO reference
30 One current per wire line for grids and stars in the image family (−3 … −5 %)? moved into 2026.11.0 (user decision of 2026-11-14, stream w1sol): grids one owner per wire line (−1.2 … −5.5 %), building outlines per side (Q44); a star alone does not change (equal arm currents), its remaining error is on the roadmap changelog
31 Make the soft size notice (5 000 segments) adjustable per engine as well? yes stream d2solver
32 Read a thin conductor inside a thicker one as a concentric cable only with an explicit marker? moved into 2026.11.0 (user decision of 2026-11-14, stream w1sol): marker conductor_type="cable_shield" changelog
33 No internal inductance of a solid wire for cable shields (100 m coaxial pair 31.97 instead of 26.97 µH)? moved into 2026.11.0 together with 32: 26.97 µH; sub-pieces add up since audit W1A-02 (stream fw1sol), also tilted against each other since audits W1R2-01, W1R3-01 and W1R3-02 (streams fw1r2sol, fw1r3) changelog
34 Tighten the rule for segments up to a quarter skin depth under sommerfeld (step of 3.5e-4 at δ/4)? a later release (2026-11-08); moved into 2026.11.0 by the user decision of 2026-11-14 done in 2026.11.0 (streams w3perf, fw3perf): exact one-dimensional self rule and graded close-pair rule; with the λ grid of audit W3B-01 the self correction is within 1.1e-9 of a refined rule from 1 m and 0.01 δ to 3 km at 50 Hz and 1 kHz for the soils tested (up to 3.4e-9 in high-contrast soils, audit W3R2B-08), no step (was 4.8e-4, step 3.5e-4); close pairs within about 4e-8 (were up to 1.5e-3); five golden cases move by up to 4.9e-7 (changelog)
35 Radial trunk: a building in a substation slot taps its feeder's trunk instead of getting its own line from the substation? moved into 2026.11.0 together with 22 (stream w1gen) changelog
36 Presets of the effective-resistivity weights per electrode class, with the values of the AP2 hand-over? yes streams d2soil, f2gen

The audits of the decision streams left four more questions, answered on the same day; the author again followed the recommendations and chose the next release for 37 and 39, this release for 38, and for 40 a quantification only once a 3-D volume reference exists. The earlier wording of 37 pointed to a "conforming axisymmetric" roadmap item that did not exist yet. With the user decision of 2026-11-14, 37 and 39 moved into 2026.11.0, and the 3-D model of wave 4 gave the reference that 40 waited for; the rows say where each was done.

Q Question Decision Where
37 Stop adding rules to the equivalent-hemisphere reduction of fem, in which every audit round found new limit cases (an interface 1 cm below a deep ring +191 … +308 % without a message; a rod reaching 1 µm … 8 cm into a more conductive top layer −44 … −78 %, warning only)? yes; no further rules, replaced by a conforming axisymmetric model (rod on the axis, ring, ring with central rod; other electrodes refused until a full 3-D method exists); planned for a later release on 2026-11-08, moved into 2026.11.0 with the full 3-D model by the user decision of 2026-11-14 implemented in 2026.11 (streams w4axi, w4fem3d; fixes of audits W4A / W4B in fw4axi, fw4fem3d): conforming axisymmetric model of rods on one axis and rings around it (about 1e-4; rings next to a conductive layer 3.3e-4 since W4A-01), and a three-dimensional conforming model for every other world — strips, grids, meshes, several clusters, galvanic distributed conductors — within 2e-3 of the axisymmetric model away from interfaces and other wires (W4B-01/-02) and between image_2layer and mom at the AP1 station; the 3-D port limit is the option FemOptions.max_ports_3d (stream fw4int); the equivalent-hemisphere reduction is gone (changelog)
38 Which owner model stays when concrete_model is removed: one current per rectangle without cross-braces (up to 2.2 % above the reference with one current per segment) or one per side (up to 0.9 %; short side at least 1 m)? one per side, already in 2026.11.0: concrete_model has no effect stream d3gen
39 Record the effective-resistivity preset in the BusType document (for example metadata["rho_preset"]), so that a bus paired with the wrong preset is detectable? yes, in a later release (2026-11-08); moved into 2026.11.0 by the user decision of 2026-11-14 done in 2026.11.0 (streams w3perf, fw3perf, fw3r2b): rho_preset of the exporters, metadata["rho_preset"], BusTypeSpec.rho_preset, the last line of the description of the live BusType and of its database entry (bustype_rho_preset; audit W3B-06), RhoPresetMismatchWarning from evaluate_spec / bustype_from_spec; a document holds a known preset name or null, and only an exact preset line of a description is replaced (audit W3R2B-06); older documents load with None (changelog)
40 Quantify the overlap of the concrete shells at the corners and crossings of encased foundations? only once a 3-D volume reference is available quantified in 2026.11 (stream w4fem3d, audit W4B-05) against the concrete resolved as a volume in the 3-D fem model: a junction acts like a few cm of wire, at most about 2 r_b, sign not settled (not converged); the generators' house mesh changes by about 1 % or less (0.35 … 0.85 % re-measured after W4B-01); no correction rule (concrete shells)

The audits of stream d3gen (D3A-02, D3A-03, D3B-03, D3B-04) found that the generators attach PEN conductors at the connection point of a foundation's anchor, which is a corner for rectangular foundations in this release (meshes since audit A2G-04, rings since Q38; the centre of one grid mesh in 0.15.0) and the first vertex for building outlines; the author decided on 2026-11-14:

Q Question Decision Where
41 Where do the conductors the generators route to a foundation end: at the centre as in 0.15.0, at the corner of the anchor side, or at the point of the foundation nearest to the conductor? at the nearest point, for every foundation form (rectangles, building outlines, the substation's foundation), already in 2026.11.0 streams f4gen, f5gen, f6gen (audits D3A, D3B, R4A, R4B, R5A, R5B, R6A); rings and strips since Q43 and layout cables clipped at every site they pass since audits R6A-01, W1B-03, W1B-04 (streams w1gen, fw1gen) (changelog)

The hand-over of 2026-11-14 left three questions; the author answered them the same evening and decided to integrate (almost) every open roadmap item into 2026.11.0 before the release — everything scheduled for the next release, the items left open, and the full 3-D FEM; out of scope stay the BranchType export to groundinsight, the import of measurement setups from groundmeas, the AP1 reference-case library and scaling the LU solve to 10 000 segments.

Q Question Decision Where
42 Route service drops around foundations (street geometry) instead of the shortest connection? no, keep the shortest connection no code change; known limitations, roadmap (row of the TN generator)
43 Apply the nearest-point rule of Q41 also to sites earthed by a RingElectrodeSpec circle or a strip (the default substations)? yes done in 2026.11.0 (stream w1gen): every conductor routed to such a site ends at the point of the electrode nearest to it (a circle exactly), rods keep their head (changelog)
44 One current per straight wire for building outlines? yes, together with Q30 (one current per wire line in the solver) done in 2026.11.0 (stream w1sol); straight runs at projected coordinates since audits W1A-01 and W1R2-05 (streams fw1sol, fw1r2sol), in linear time since audit W1R3-03 (stream fw1r3) (changelog)

The decisions D1–D9 taken while these items were implemented are listed in Decisions of 2026-11-15, before the sections of the four waves at the end of this page.

Correction to question 38 (audit D3B-01)

The 0.9 % of question 38 was measured at the cases where the owner change is largest. Over the whole scope of the owner texts (short side at least 1 m, aspect ratio up to 50, sides up to 150 m, the AP1 soils) one owner per side is at most 1.4 % above one current per segment (150 m × 3 m bare in 30 over 200 Ω·m: +1.34 %) and one owner per rectangle up to 2.2 % (16 m × 1 m in a 0.2 m shell of 30 Ω·m over 1000 / 30 Ω·m: +2.106 / +2.160 % at 0.5 / 0.25 m segments); one per side is closer everywhere, so the decision stands.

Corrections (adversarial audits of the decision streams)

Two adversarial audits of the three decision streams below (D2A / D2B, fixed by the streams f2solver and f2gen; R2A / R2B, fixed by f3solver and f3gen) corrected these statements; the release notes describe the release:

  • d2solver, Q23: the rule also covers a more conductive layer below the hemisphere but within the electrodes' horizontal half-extent when no more resistive layer lies in between (the error is continuous across a_eq, −67.9 % on both sides for a 10 m ring over 1000/30 Ω·m; an extension by the coordinator, for the author's review). A horizontal wire touches the layers that hold its axis (within its wire radius only for the rule of an electrode below its hemisphere); a rod end on an interface does not touch the layer beyond. fem misplaces the current by −97 … +30 % in the rejected worlds (mostly far too low); more resistive spanned layers are −3 … +48 % off, not +3 … +45 %; none of the rejected worlds was silent before, they warned. fem also refuses strips deeper than half their length, rings deeper than their diameter, driven MeshElectrodes and electrodes and galvanic conductors out of the soil, and names only backends whose own checks accept the world.
  • d2gen, Q20: the brace table is measured against the bare braces of the development line, which were never released; in 0.15.0 the braces had the shell radius without the shell resistance, and against the 0.15.0 "distributed" model the brace rule alone is +5.9 / +66 / +393 % at ρ_c = 150 / 1000 / 5000 Ω·m. The hand assembly that reproduces the solve is a check of the generator with the same kernel and owner model, not an independent method (an independent boundary- element model confirms the numbers; with one current per segment the brace effect is +49.2 / +318.5 % instead of +46.9 / +307 %).
  • d2gen, Q21: concrete_model changes the impedance of an axis-aligned rectangle without cross-braces (also style="mesh" with n_x = n_y = 1) by less than 1 % up to aspect ratio 4 and 2 % up to 50 over the AP1 soils (short side at least 1 m; 5 mm wire at 0.8 m, bare or in concrete of 30 … 1000 Ω·m up to 0.2 m thick; largest values found 0.69 / 1.55 %), not by at most 0.16 % / 0.67 %, and the premise of question 21 (≤ 0.06 %) holds only for bare rings in homogeneous soil (0.09 % / 0.33 % measured): flagged for the author's review.
  • d2soil, Q36: the medians 1.8 % / 5.0 % are over all 39 AP1 soils with the homogeneous ones at zero (2.1 % / 5.5 % over the 36 two-layer soils); that the hand-over's 1.7 % / 15.7 % are this metric is an inference (groundfield 0.14.0 itself at 1.5 m segments reproduces them).

Stream d2solver: User decisions Q23, Q27, Q31: fem and more conductive layers, perfect_mirror across the surface, per-engine size notice

Changed

  • ⚠ fem (experimental) raises BackendCapabilityError when the equivalent hemisphere of a cluster spans a layer that no electrode of the cluster touches and that conducts better than every layer the electrodes touch (user decision Q23, finding 10.23). The hemisphere injects the current straight into that layer and the result is too low: −97 … +5 % against image_2layer and mom in the measured cases (rods, strips and rings below a more conductive top layer from 22 mm thickness, rings above a more conductive lower layer; −92 % for a 10 m ring at 0.8 m over 1000/30 Ω·m at h₁ = 2 m). Up to now a FemReductionWarning or silent. The rule is structural (near-equal 100/120 Ω·m raises as well), uses the canonical layer stack, and an electrode exactly on an interface touches both layers; the message names the cluster, the layer, the electrodes' ρ, a_eq, the measured range and a backend that solves the world. More resistive spanned layers keep the warning (+3 … +45 %). Tests: tests/test_fem.py::test_fem_rejects_a_more_conductive_layer_its_hemisphere_spans and four siblings.
  • earth_inductive_model="perfect_mirror" emits one UserWarning per solve when inductive conductor segments lie on both sides of the soil surface, naming the number of such pairs and the conductors and pointing to "sommerfeld" (user decision Q27, finding 10.46): its additive image has no physical basis for an overhead/buried pair (2.28 / 2.77 times the mutual reactance of sommerfeld at 50 Hz / 1 kHz for a lead 1 m above a PEN 0.7 m deep). Numbers do not change. Tests: tests/test_inductive_solver_integration.py::test_perfect_mirror_warns_for_inductive_pairs_across_the_surface and siblings.

Added

  • Engine.warn_segments (int | None, default None = diagnostics.SOFT_LIMIT, 5 000, read at solve time): the size of the soft notice "solve time may run from seconds to minutes" per engine, counted like max_segments (segments and nodal unknowns); honoured by the solve's pre-flight warning, check_segment_resolution and diagnose() (report.context["warn_segments"]). Not checked against max_segments (a notice above the hard limit never appears). Booleans rejected; kept by JSON, copies and the provenance (user decision Q31, finding 10.06). Tests: tests/test_resource_limit.py::test_warn_segments_is_a_validated_engine_field and four siblings.

Numbers that change

What Size Who is affected Golden cases
none (Q23 turns results into errors, Q27 adds a warning, Q31 moves a notice) — fem users with a conductive layer spanned by the hemisphere get an error instead of a −97 … +5 % result none

Stream d2gen: User decisions Q20, Q21: encased mesh braces, concrete_model deprecated

Changed

  • ⚠ Mesh foundations: the cross-braces are encased (user decision Q20). A foundation earth electrode per DIN 18014 lies in the concrete together with its connections, so every wire of an encased FoundationElectrodeSpec(style="mesh") — the perimeter and the cross-braces — carries the outer radius \(r_b = r_a + t\) and the shell coefficient \(C\); up to now the braces stayed bare, and a foundation could not exceed the spreading resistance of its braces alone however dry the concrete. Without a shell nothing changes. See Numbers that change. Tests: tests/test_concrete_one_mechanism.py::test_mesh_braces_are_encased, ::test_encased_mesh_equals_the_assembly_of_its_wires, ::test_shell_of_a_mesh_foundation_spans_every_wire.
  • groundfield.generators.materialise.concrete_shell takes encased_length_m (the keyword perimeter_m of the earlier 2026.11 work is gone) and reports the shell resistance \(C/L\) over every encased wire.

Deprecated

  • FoundationElectrodeSpec.concrete_model (user decision Q21). The field no longer selects a shell model; it only chooses one current owner ("lumped", the default) or one per side ("distributed") for an axis-aligned style="ring" rectangle, at most 0.16 % apart up to aspect ratio 4 and 0.67 % up to 50 over the soils of the AP1 grid, bare or in concrete of 30 to 1 000 Ω·m (0.06 % / 0.3 % for a bare ring in homogeneous soil). "distributed" keeps working and emits a DeprecationWarning at the user's line (constructor, model_validate, JSON, model_copy that sets it); "lumped" and the configuration JSON and pickles of 0.15.0 load silently; the generators do not repeat the warning. Drop the argument; removal no earlier than 2027.5. Tests: tests/test_foundation_owners.py.

Numbers that change

| Q20 (10.13) | the cross-braces of an encased mesh foundation carry the concrete shell like its perimeter (DIN 18014; user decision Q20) | default house mesh (10 m, 2 × 2, 0.8 m, r_a 5 mm, t 5 cm) in 100 Ω·m −1.1 / −0.03 / +1.5 / +47 / +307 % at ρ_c = 50 / 100 / 150 / 1 000 / 5 000 Ω·m, in 30 / 100 Ω·m (h₁ = 5 m) +1.3 / +6.2 / +12 / +154 / +861 %; medium_industry mesh (20 m, 3 × 3) −1.3 … +298 % and +1.0 … +671 %; no golden case moves | generated mesh foundations with concrete_rho_ohm_m set; not worlds without a shell (the default building catalogue), not ring and building-outline foundations, not AP1 |

Stream d2soil: User decision Q36: effective-resistivity presets per electrode class

Added

  • Effective-resistivity presets per electrode class (user decision Q36). gf.effective_resistivity(soil, preset=...) takes the weights \((w_0, \beta)\) from the read-only mapping groundfield.soil.EFFECTIVE_RESISTIVITY_PRESETS, with the values of the AP2 hand-over (2026-10-20, AP1 catalogue computed with groundfield 0.14.0): "lv_network" (0.13, 0.8; the default, the AP1 calibration), "station" (0.06, 1.3; the station electrode alone) and "lv_group_<g>_p<pp>" for the four LV network groups (perimeter equivalent \(n_U\), thresholds 20 / 100 / 250) and 5 / 10 / 20 / 40 % foundation electrodes (method A, q50). An explicit w0 or beta replaces that weight only; an unknown name raises ValueError naming the closest presets. For the AP1 station in the 39 AP1 soils, \(R = c\,\rho_\text{eff}\) misses the field solution by a median 1.8 % and at most 15.7 % with "station" (hand-over: 1.7 %, 15.7 %), against 5.0 % and 35.9 % with "lv_network". Tests: tests/test_effective_resistivity.py (presets section, test_the_station_preset_reproduces_the_handover_for_the_ap1_station, test_the_documented_tables_hold_the_presets).

Changed

  • effective_resistivity: w0 and beta default to None, the value of the preset; every call keeps its value bit for bit (default preset "lv_network" = 0.13, 0.8). The IO reference example fits the station over \(\rho_\text{eff}\) with preset="station" (max_relative 7.48 % instead of 13.41 %); Soil reference, ADR-0008 (amendment item 5) and glossary describe the presets and that a BusType and its bus must use the same one.

Numbers that change

none (no library value moves; golden unchanged).

Streams f2solver, f2gen, f3solver, f3gen: fixes from the audits of the decision streams

Two adversarial audits attacked the work of the three decision streams; four fix streams answered them. Their notes were written as instructions for the release notes, which now carry the result (the box above lists what they corrected); in short:

  • f2solver (audit D2A): one contact predicate for the layer rules of fem; Q23 within the electrodes' horizontal half-extent; documented ranges re-measured; a remedy only from backends whose own checks accept the world; electrodes out of the soil refused like in every backend; strips and rings deeper than their formulas and driven MeshElectrodes refused; conductor names with a line break in the perfect_mirror warning; which entry points emit the size notice.
  • f2gen (audit D2B): encased mesh foundations measured against 0.15.0 (the bare braces existed only on the development line); the concrete_model bound with its scope and rectangles without cross-braces; model_copy validates concrete_model; the shell helper over every encased wire; the hand-over's station metric marked as inferred.
  • f3solver (audit R2A): only a rod is non-horizontal (round-off in a strip's end depths); the wire-radius band only for the rule it makes stricter, Q23 and the A2E-2 rule on the wire's axis again; no Q23 error for a conductive layer behind a more resistive one within the half-extent; ring depth limit at the diameter; galvanic conductors out of the soil refused; remedies with the setting that lifts a refusal; ranges with converged image series.
  • f3gen (audit R2B): the concrete_model bound with the short side in both clauses, a margin over the largest values found and its model uncertainty; model_copy of subclasses; copy.replace warns at the caller's line on Python ≥ 3.13.

Stream d3gen: User decision Q38: one current owner per side

Every rectangular foundation without cross-braces (style="ring", or "mesh" with n_x = n_y = 1) is one strip per side, bonded to its local −y side, at every orientation; FoundationElectrodeSpec.concrete_model keeps its validation and loads from JSON but has no effect ("distributed" warns, "lumped" stays silent). Up to this change the default "lumped" made an axis-aligned rectangle one GridMeshElectrode. The release notes carry the details; in short:

  • Size: the input impedance is never higher and unchanged for a square on its own. Over the AP1 soils (short side at least 1 m) the largest decreases are −0.32 / −0.91 % bare or with the default shell and −0.69 / −1.53 % in up to 0.2 m of wet concrete (aspect ratio up to 4 / 50), confirmed by the side-matrix algebra and an independent boundary-element solver; the AP1 station −0.0009 … −0.0026 %.
  • Connection point and names: conductors attached to the foundation by name start at the corner of its −y side instead of its centre, and the electrode named after the foundation is that side (cluster_impedance for the foundation), as for meshes and rotated rectangles.
  • fem: the four strips are reduced as a cluster; no new rule (user decision Q37), the changes are listed in the fem row of the release notes and in the known limitations.
  • Golden: only mutual_foundations_lumped_concrete moves (Z_G 5.2e-4, R 1.6 %, structure of the world), now equal to the distributed case.

Stream f4gen: User decision Q41 and the fixes of audits D3A, D3B

Every conductor that TnNetworkGenerator and the layout builder route to a foundation ends at the point of that foundation nearest to the conductor: a service drop is the closest pair of its feeding cable and the building's foundation wires, a cable leaving a site with a foundation starts at the foundation's point nearest to its next node, and the conductor is attached to the wire that holds the point. Ties go to the lowest wire index, then to the smallest arc position. Sites without a foundation keep their connection point, and so does everything attached by name. The first version joined a cable that crosses a foundation to it without a drop; the audits of the stream completed that rule (see the f5gen and f6gen sections). In short:

  • Drops: of the 282 drops of audit D3A's ring-house set (11 968.5 m), 47 ran along their own foundation and 45 across it; the first version had 264 drops (10 529.6 m), none along or across its own foundation, but 18 radial substation-slot drops on the trunk; now 246 drops (9 963.5 m), none on a cable (closest pair checked against 2 mm sampling).
  • Networks (seed 1, 100 Ω·m, default grid; values after the audit fixes, see the f5gen section): the resistive PEN at 50 Hz moves by −0.005 … −0.12 % (star) and −0.03 … +0.13 % (radial); with a Neumann PEN at 1 kHz |Z| by −0.71 … +3.3 % (star) and −0.67 … +9.0 % (radial). The 12 m × 8 m ring houses of audit D3A have +5.7 … +14.0 % more reactance than drops to the centre as in 0.15.0; the default 10 m ring networks with drops +1.2 … +2.1 % (star, 30 houses) and −10.8 … −1.1 % (radial).
  • A layout of building outlines with an AP1-like station: −0.026 … −0.147 %, drops 215.9 → 140.6 m. The AP1 catalogue itself attaches its drops and bonds by name and is not changed by Q41 (audit R4B-14).
  • Fixes: right angles are exact rotations and keep the anchor side (D3B-04, D3A-05); non-positive foundation sides raise (D3A-01); diagnose() leaves out the pairs of one foundation's wires that meet at its corners (D3A-04; since audit R4A-04 only wires bonded by the foundation's _bond_ conductors and only pairs at a shared vertex); the per-side bound is 1.4 % (D3B-01, see the correction above); the texts on the connection point, the golden field change and the fem ranges are corrected (D3A-03, D3A-06, D3B-02, D3B-03, D3B-05 … D3B-07).
  • Golden: gen_tn_default (≤ 2.9e-4), gen_layout_builder (≤ 1.1e-3) and gen_tn_measurement_overhead_leads (≤ 1.6e-4, the probe reading 4.3e-3) move; the other 46 cases are bit-identical.

Stream f5gen: Fixes of audits R4A, R4B (user decision Q41)

The audits of stream f4gen found three routing paths that broke the rule — drops that started on the foundation of a house the cable crosses (R4A-01), radial drops from the substation that lay on the trunk through the houses it crosses (R4A-02, R4B-01: 6 drops over 195 m in the default 30-house network), layout taps inside the station foundation (R4A-03) — an over-broad diagnose() grouping (R4A-04), unchecked plan contacts (R4A-05), a slower planner (R4A-06) and scoped or stale numbers (R4B-02 … R4B-14). In short:

  • Crossings: a building that a cable crosses is joined to it and fed by it, without a drop: a cable of its feeding path, every trunk of the radial topology, and in the star topology the main that crosses it, whose cabinet then feeds it (coordinator decision: no cross-ties between cabinets through a house; 1 of 50 and 3 of 150 default houses change cabinet). No drop runs along a cable farther than one minimum section (1 cm): a drop from a node that would run along a trunk or another main starts where it leaves it (needed by the random stress set). The guard, with the router's 1 cm tolerance since audit R5A-01, finds no drop along a cable in the default grids and audit D3A's set; in the 400 random networks one drop shares the 1 cm of rule 3's bound (a foundation 8 mm beyond a cabinet rod at the cable's end), which the guard allows.
  • Numbers, scoped (seed 1, 100 Ω·m, default grid; sommerfeld and carson_series, two segment lengths): Q41 moves resistive networks by −0.005 … −0.12 % (star) and −0.03 … +0.13 % (radial) at 50 Hz; with a Neumann PEN at 1 kHz Im −3.1 … +16.3 % (star; the 10-house network with 5 of its houses on the main +14.2 / +16.3 %) and −8.6 … +37.7 % (radial; default 30 houses +10.4 %). Radial networks react to where the drops end much more than star ones.
  • Other fixes: diagnose() groups only the wires bonded by a foundation's _bond_ conductors and leaves out only pairs that meet at a shared corner; plan contacts off their wire, unknown or on a rod are rejected; planning one cabinet feeding 1000 houses 3.14 → 0.89 s; LvNetworkLayout.plot(world=...) draws the drops as built; one owner up to 2.2 %, the scanned 145 m × 2.9 m rectangle, the passive-field change +5.5 / −4.7 % and the provenance of the touch-voltage values corrected.
  • Golden: nothing moves against f4gen.

Stream f6gen: Fixes of audits R5A, R5B (user decision Q41)

The second audit round found one regression of the first round's fixes and three smaller routing gaps — layout taps next to a rotated, polygon or offset station or cabinet foundation were computed on the slanted first section and refused, so the drops fell back to the station, the cabinet or the far end of the cable, 14.0 … 36.5 m instead of 6.0 m (R5A-02); "along a cable" was tested to 1 µm, so a drop 2 µm beside a trunk ran 60 m along it (R5A-01); a cable touching a house at its end node and crossing it elsewhere gave it a 1 cm drop (R5A-03); radial planning grew faster than the network (R5A-04) — and texts that stated the pre-fix rules or unscoped numbers (R5B-01 … R5B-13). In short:

  • Layout: the taps stay on the layout polyline, clipped at the projection of the site contact onto it; no tap on the first or last segment inside a site foundation (a cable corner inside one stays a node, audit R6A-01); audit R5A's 40 random layouts: drops more than 1 cm longer than the closest pair of the built cable 30 → 6 (e91f3c0: 7).
  • Routing: "along" means both ends of a cable section within one minimum section (1 cm) of the drop's line, the guards use the same value; a crossing beyond a touching node is the joint; set lookup (radial 8000 houses with max_feeder_length_m=1e5 43.6 → 18.4 s, plans bit-identical). The default grids, audit D3A's set and the 260 random networks of the stress tests are unchanged.
  • Drops over other foundations: 0 … 80 % of the drops of the default grids run 0.2 m above other houses' side wires; moved 1 m aside they change |Z| by at most 0.02 % (insulated PEN) and −0.30 % (bare PEN). Routing drops around foundations was left to the next release; the author then kept the shortest connection (user decision Q42).
  • Golden: nothing moves.

Verification audit R6A of stream f6gen

A focused third round on the fixes of stream f6gen reproduced them (the layout clip of R5A-02 bit for bit against e91f3c0 in the auditor's five cases, the 1 cm rule changing only the 73 near-collinear drops of the stress set, the joint search, the bit-identical set lookup, and the sensitivity of drops over other foundations: bare PEN −0.30 %, insulated +0.02 %, two discretisations each). It found that a router corner inside a small cabinet ring stays a node that houses tap (R6A-01: 82 of 2 540 drops in 200 random layouts, also before user decision Q41) — documented as a known limitation and scheduled in the roadmap — and five scoping and wording points (R6A-02 … R6A-06: an evidence line of the stream's report, the max_feeder_length_m=1e5 of the 8000-house timings, the definition of "along" in the 10.38 row, the frequency of the detour reactance, the substation drop in tutorial T06), which the release notes, the known limitations and the tutorial now state.

Decisions of 2026-11-15

While the items of the user decision of 2026-11-14 were implemented, eight questions came up (D1–D8), each with a recommendation. On 2026-11-15 the author followed every recommendation and asked, for D6, to stay with licences that allow further commercial use and are as free as possible. During the waves he decided two more: the form of the far images of the two-layer image series and D9. The table keeps the question, the recommendation that is now the decision, and where it was done.

id Question Decision Status and where
D1 Give VoltageSource an internal impedance Z_q = R + jωL (two fields, one diagonal entry of the source's constraint row)? Without it: a junction with a conductor, or the 1 A solve scaled by hand. yes (small, useful for AP2) done in 2026.11.0 (stream fw2src): internal_resistance_ohm, internal_inductance_h, 0 by default and then bit-identical to the ideal source; pickles written before it load as ideal sources, and a galvanic mom world factorises once for all frequencies (audits W2R2-01, W2R2-02, stream fw2r2) (changelog)
D2 Make the near/far switch of the line kernel continuous (a deterministic margin or a far form exact to round-off), so that results do not depend on where a world stands? It moves worlds near the origin, estimated at about 2e-7 (audit W2B-02: 1.15e-5 for the switch alone in golden line_img2_rod_crosslayer). yes, in stream w3xl (the numbers move far below every tolerance; reproducibility wins) done in 2026.11.0 (stream w3xl, item 5): a C¹ blend between 6 and 7.5 segment lengths; 1e-13 over local shifts, ≤ 5e-11 at UTM coordinates (audit W3A-04); with the far images and the cross-layer line form of the same stream the golden line-kernel cases move by up to 6.0e-4 (changelog)
D3 A current that varies along each wire in the image family (stars +1.8 … +10.4 %, 8 arms in 1000/100 Ω·m +12.3 %; grids +0.36 … +0.70 % above one current per segment)? roadmap (mom is the per-segment answer today) open: roadmap
D4 The generator rules wave 1 left open: a group rule for wide groups (about 180°), one cabinet around the substation, a cabinet that cannot keep its clearance (it raises; it could move on along its ray)? roadmap; the raise is a clean failure open: three items of the roadmap
D5 Worlds that mix projected (UTM) and local coordinates are not helped by the shifted local frame of stream w2mom: what to do about them? document them, once audit W2B has quantified them quantified by audit W2B-04 and done in 2026.11.0 (stream fw2mom); by the coordinator's decision on W2B-04 beyond the text: diagnose() reports such a world under coordinates, and its solve warns with MixedCoordinatesWarning (known limitations, changelog)
D6 Dependencies of the 3-D FEM as an optional extra of the MIT package (meshers: gmsh GPL-2.0-or-later with exceptions, netgen LGPL, TetGen AGPL; scikit-fem BSD-3, pyamg MIT)? permissive licences only (MIT / BSD / Apache): scikit-fem with its own tensor-product meshes and pyamg; no GPL / AGPL; a weak-copyleft mesher only if nothing permissive works, and then ask again done in 2026.11.0 (stream w4fem3d): the optional extra fem3d with scikit-fem (BSD-3-Clause) and pyamg (MIT); the design needs no surface-fitted mesh, so no external mesher and no copyleft package (changelog)
D7 A continuous cabinet rule instead of the 20 m threshold, which moves a cabinet by up to 142 m for a 0.2 m change of the house spacing (X at 1 kHz about −20 % in the 50-house grid; AP1 mixes with groups at 18.8 / 20.2 / 20.7 m; audit W1R2-02)? keep the threshold for 2026.11, document the step and record the rule per cabinet; the AP1 catalogue does not use the generator's cabinets done in 2026.11.0 (stream fw1r2gen): the plan records PlannedSite.cabinet_rule and PlannedSite.centroid_ray_gap_m per cabinet, the known limitations give the step (141.8 m, X at 1 kHz −21.6 / −18.9 % with carson_series / sommerfeld); a continuous rule is on the roadmap
D8 Rebase the golden baseline for 2026.11.0 after the last wave, since the declared bounds of many streams add up and no longer bind (audit W1R2-07)? yes, as the last step before the release dry run done in 2026.11.0: the baseline regenerated from the code of 2026.11.0 (563 quantities in 48 cases); the declarations of the cycle moved to tests/golden/expected_changes/released/2026.11.0/
D9 Service drops that leave one tap in one direction (the radial taps, the substation drops of the star) lie on one axis, where the inductance matrix reads every pair as touching (diagnose(): 10 overlapping pairs in the 5-house radial network, 247 with 200 houses): keep them, or lay them side by side? in a row side by side at the touching distance; only neighbours touch done in 2026.11.0 (stream fw3perf; along one common normal under placement jitter since audit W3R2B-01, stream fw3r2b): PlannedBranch.axis_offset_m; X at 1 kHz of the 5-house radial network −2.33 / −2.70 % (carson_series / sommerfeld); no generated network reports an overlap for jitter_m 0 … 0.1 m; no golden case moves (changelog)
far images Which form do the far images of the two-layer image series take (stream w3xl, item 1)? the quadrupole form stays the default (the reference model); an Engine option gives the point form for fast parameter studies done in 2026.11.0 (stream fw3xl): Engine.image_far_field = "quadrupole" \| "point"; the TN 40-house network in 1000/30 Ω·m with h₁ = 1.5 m solves in 0.49 of the default's time; since audit W3R2A-01 (stream fw3r2a) the point form keeps the near image pairs on the cross-layer path, and a 75 m strip below the interface is within 1.1e-5 of its exact value at any segment length (up to −58 % before) (changelog, known limitations)

Waves 1 to 4 of the extended release

On 2026-11-14 the author moved (almost) every open roadmap item into 2026.11.0 (see the decisions above). The work ran in four waves, each with implementation streams on disjoint files, the coordinator's texts, a first round of two adversarial audits, fix streams with the coordinator's decision per finding, and a second audit round that attacked the fixes, again followed by fixes; wave 1 had a third, verifying round, and the rounds of wave 4 after audit W4A follow at the release. The audits number their findings per round (W1A-01 … W4A-11). Wave 1 with its first fixes and audit W1R2, and the wave-2 streams, ran in the cloud workspace (Linux x86-64, OpenBLAS); the rest ran on the author's Mac (macOS arm64, Accelerate), where every claim of bit identity is made against a golden baseline generated on the same machine. As for the streams above, the release notes carry the result; the sections below say what each stream and each audit round did, with the numbers as corrected by the later rounds.

Wave 1: one current per straight wire, concentric cables, cabinets per building group

Wave 1 implemented the user decisions Q30 / Q44 and Q32 / Q33 in the solver and the coupling (stream w1sol), and Q22 / Q35, Q43 and the layout fix of audit R6A-01 in the generators (stream w1gen); Q42 needed no code. Its audits ran three rounds: W1A / W1B, W1R2 on the fixes, and the verification round W1R3.

Stream w1sol: one current per straight wire, concentric cables by marker (Q30, Q44, Q32, Q33)

image, image_2layer (with its cross-layer path) and solve_mutual_* give every grid one uniform-current owner per full wire line, a star one per arm and a polyline one per straight run; the owners of an electrode are ideally bonded, every result stays per electrode, and metadata["wire_owners"] counts them. Rods, strips and rings stay one wire; generated mesh foundations, one electrode per wire line already, do not change. In the coupling, a thinner conductor on the axis of a thicker one is a core inside a shield only when the thicker one has conductor_type="cable_shield", and a shield has no internal inductance of a solid wire. In short:

  • Grids: −1.2 % (10 m, 2 × 2 meshes) … −4.0 % (40 m, 8 × 8) … −5.5 % (100 m, 20 × 20) in 100 Ω·m; above one current per segment +0.36 … +0.70 % instead of +1.6 … +4.9 %. Against mom, at the corner of the 20 m grid with 4 × 4 meshes: touch voltage +6.4 % (+20 % before), step voltage −7.6 % (−21 %); the touch-voltage envelope of the 10.21 note 111.44 → 98.72 V.
  • Outlines and stars: a building outline is one owner per side and equals the rectangle given by its size (rectangle outlines −0.000 … −0.31 % bare, −0.62 % in wet concrete; the T06 layout with the AP1 station −0.03 … −0.40 %). A star alone does not change (equal arm currents); its gap to one current per segment stays on the roadmap (decision D3). A source-free grid, star or polyline floats at one potential with exactly zero net current.
  • Concentric cables: two unmarked conductors on one axis are separate cables that touch (a 100 m pair of 5 mm and 15 mm radius: loop 31.97 → 43.47 µH, the analytic 43.48 µH); the self terms of a shield drop μ₀ℓ/(8π) (50 nH/m), and the 100 m coax reads the analytic 26.97 µH instead of 31.97 µH. buried_lead() is a shield: two-pole readings with buried leads −2.5 % in reactance.
  • Golden: img2_grid_upper_resistive (Zc −0.94 %), cim_grid_unequal_segments (−1.41 %), img_mixed_cluster_hom and line_img_mixed_cluster_hom (−0.20 %, electrode currents up to 3.4 %) move; Q32 / Q33 move no stored case. The refinement bound of benchmark B11 is 0.6 % instead of 0.5 %.

Stream w1gen: cabinets per building group, the nearest point on rings and strips (Q22, Q35, Q43, R6A-01)

The star topology of TnNetworkGenerator orders the buildings by bearing around the substation, from the widest angular gap on, cuts them into one run of consecutive bearings per cabinet (sizes differ by at most one) and places each cabinet on the ray through its group's centroid, 1 m (CabinetConfig.end_clearance_m) beyond the group. In the radial topology a building in a substation slot taps its feeder's trunk (Q35). Every conductor routed to a site earthed by a ring or a strip, the default substations among them, ends at the point of that electrode nearest to it (Q43), and a layout cable reaches a site where its polyline enters the site foundation (R6A-01). In short:

  • Default networks: the 30-house star had both cabinets west of the substation and fed its eastern houses by drops of 3.5 … 106.5 m from the substation (25 drops, 1 140 m); its cabinets now stand at (−118.5, 0) and (118.5, 0) m with 20 drops of 25 m. The 30-house radial network: drops 1 115 → 778 m, 14 → 4 of them from the substation. The default mains leave the substation ring at its point nearest to their cabinets.
  • Numbers (default grids of 10 … 150 houses, 100 Ω·m, with the fixes of fw1gen): resistive PEN at 50 Hz star +0.12 … +0.85 %, radial −0.01 … +0.49 % (Q43 alone −0.05 … −0.13 %); an isolated Neumann PEN at 1 kHz (up to 50 houses) star |Z| −1.4 … +13.1 %, radial −1.2 … +15.4 %. The reactance of the default 30-house star rises by +64 / +55 % (carson_series / sommerfeld), because its houses share their main instead of parallel drops (audit W1B: the rise comes from the tree, +52 % in an own lumped model, +54.9 % with mom).
  • Golden: gen_tn_default (substation potential +1.18 %, the current of the cabinet rod −62.7 %: the rod stands 1 m beyond the houses instead of 62.5 m) and gen_tn_measurement_overhead_leads (+1.76 %, the probe rod's potential +117 %) move; the other 47 cases are bit-identical.

Audits W1A and W1B of the wave-1 streams

Two auditors attacked the merged wave 1 (snapshot 6f63deb, change from e6124cd) with code of their own, W1A the solver and coupling side, W1B the generators. Findings:

  • W1A-01 (medium): the absolute collinearity tolerance (a sine of 1e-9) split the wire lines of rotated generated meshes at UTM coordinates into extra owners (a 10 m mesh with 10 × 10 meshes: 142 extra owners, −0.55 %; up to −0.64 %).
  • W1A-02 (medium): the coax loop inductance shrank with the number of pieces (26.966 µH lumped, 24.608 µH in 0.25 m pieces, −8.8 %).
  • W1A-03 (low): the 10.21 row still gave 69.6 V at +x; since Q30 it is 59.95 V (point kernel), 61.31 V (line kernel), 61.58 V (mom).
  • W1A-04 (low): the owner texts of the generators described one leakage current per electrode.
  • W1A-05 (low): model_copy bypassed the rule that a shield has no skin model.
  • W1A-06 (low): diagnose() counted one owner per electrode (102 instead of 393 unknowns).
  • W1A-07 … W1A-10 (info): a lone floating split electrode reported -0-0j; the roadmap had lost the star item and three decision rows of this page were stale; two documentation points on shields.
  • W1B-01 (medium): a group spanning about 180° got its cabinet in empty ground (10 houses and one small commercial building: 50.4 m from the nearest building, drops 527 instead of 337 m).
  • W1B-02 (medium): the clearance looked only at the group's horizontal wires; a cabinet rod stood at the point of a building's rod.
  • W1B-03, W1B-04 (low): the R6A-01 clip covered only a cable's own end sites, and its merge cut off cable legs that serve houses (drops 30.0 → 142.8 m).
  • W1B-05 … W1B-08 (low): end_clearance_m without a lower bound, golden bounds wider than their quantities and adding up across streams, stale texts, tests that did not check what they promised.

Confirmed: one owner per wire line equals bonded strips to 7e-15 in every engine path; an independent grid code gives the owner gaps (20 m 4 × 4 grid: +3.297 % with one owner, +0.574 % with one per wire; stars +1.81 / +3.48 / +10.54 %); 54 records outside the items are bit-identical; 26.97 µH and 43.48 µH follow from closed forms; over about 300 layouts every PEN network is one tree, every building is fed once and every drop is the closest pair; ring contacts lie on the circle within 2.5e-13 m. Taken up by fw1sol (W1A except -04 and -08), fw1gen (W1B and W1A-04) and the coordinator (W1A-08: the roadmap item and the rows).

Streams fw1sol and fw1gen: fixes of audits W1A and W1B

  • fw1sol (W1A): a vertex continues a straight wire when it lies on the chord of its neighbours up to 64 units of round-off of the coordinates (COLLINEAR_ROUNDOFF_ULPS), so generated meshes at UTM coordinates read their local value again (+0.09 … +0.64 %). Pieces of conductors lying beside each other add up: a thinner wire parallel inside a shield couples at the shield radius at every axial offset, and the coax reads 26.97 µH in any parallel pieces (it read 26.91 / 26.37 / 24.61 µH in 10 / 1 / 0.25 m pieces), the unmarked pair 43.47 µH. A copied skin shield is rejected at the solve, diagnose() counts 393 unknowns, a lone floating electrode reports 0j, and the 10.21 note gives the touch voltage after Q30. Golden: cond_drops_along_pen_main_perfect_mirror moves (X at 1 kHz +3.9e-4, Zin 1.3e-5).
  • fw1gen (W1B, W1A-04): a cabinet stays on its centroid ray, end_clearance_m beyond the group's farthest electrode (rods included) plus the plan extent of its own grounding, unless it would stand there farther than max_far_end_gap_m (20 m) from the nearest electrode of its group; then it stands on the ray through the group's far-end building. This hybrid rule is the coordinator's: the stream's first version put every cabinet on the far-end ray, which gave the 50-house grid six drops from the substation. The case of W1B-01 has its cabinet 1.56 m from the nearest building and 311.8 m of drops. A cabinet that cannot keep its clearance to another site raises, naming both; end_clearance_m is positive. Layout cables are clipped at every site they pass, and only the leading and trailing waypoints inside the end sites are merged.
  • Numbers (fw1gen): resistive PEN at 50 Hz of the default star grids of 100 … 200 houses −0.031 … +0.089 %, the mix of 10 houses and one small commercial building +0.489 %; the wide mixes with an isolated Neumann PEN at 1 kHz |Z| +0.3 … +1.9 %; layouts with a cable through a passed cabinet −0.16 … −0.45 %. The 10-, 30- and 50-house grids, the radial networks and every golden case are unchanged.

Audit W1R2: round 2 on the wave-1 fixes

The second round attacked the fixes of fw1sol and fw1gen (snapshot 1579ed8). Findings:

  • W1R2-01 (medium): the rule of W1A-02 acted only on pieces parallel within 4.47e-5 rad; at 4.5e-5 rad the 100 m coax read −0.17 … −7.42 % again in 10 … 0.25 m pieces, with a step at the tolerance.
  • W1R2-02 (medium): the 20 m threshold switches a cabinet between two positions up to 142 m apart (the 50-house grid with its house columns 32.0 / 32.2 m apart: X at 1 kHz about −20 %); the texts said it separates the group populations, which it does not (decision D7).
  • W1R2-03 (low): the bundle rule evaluated all piece pairs at once (two 600 m conductors: 30 → 292 MiB).
  • W1R2-04 (low): texts against the measurements (the AP1 gaps are 20.21 … 53.56 m, not 23.7 … 50.4 m; thresholds of 15 / 25 m move two groups of the 100-house grid, not one; a timing of the first version).
  • W1R2-05 (low): straight runs were judged per vertex triple, so a near-duplicate vertex or a finely sampled arc counted as straight at UTM coordinates.
  • W1R2-06 (low): rows 22 and 35 of this page still said "next release", and five rows linked a roadmap section that no longer listed them.
  • W1R2-07 … W1R2-10 (info): the golden bounds of several streams add up (decision D8); without conductor labels unmarked touching pieces keep the old drift; end_clearance_m ≥ max_far_end_gap_m silently sent every group to the far-end ray; World.check() let a copied skin shield through.

Confirmed: the coax and the unmarked pair add up exactly at local and UTM coordinates (1.6e-15), the W1A regressions and the ten W1B tests pass, the layout clip is clean in 17 hand-made attack cases, and the cabinet rule is deterministic and raises nowhere over the 80 AP1 mixes. Taken up by fw1r2sol (01, 03, 05, 08, 10), fw1r2gen (02 with D7, the code texts of 04, 09) and the coordinator (the other texts of 04, 06; 07 by D8).

Streams fw1r2sol and fw1r2gen: fixes of audit W1R2

  • fw1r2sol: pieces of two conductors tilted against each other get the bundle rule, with the stretches inside, beside and away from the partner found exactly (the length gate and the angular cap of this version went in fw1r3); the tilted coax returns to its lumped value (+0.004 … +8.0 %). The generator's overhead probe lead, drawn from 10 mm beside the feed lead to its axis, is such a pair: the probe junction potential moves by 6.5e-5 … 1.1e-4. The bundle rule needs memory in proportion to the matrix (292 → 30 MiB, bit-identical). Straight runs grow against the chord of the whole run (a 2° arc electrode of R = 50 m at UTM coordinates +1.27 % → +5.5e-4 against the local origin). World.check() rejects a copied skin shield. Golden: nothing moves.
  • fw1r2gen (D7): the 20 m threshold stays and the step is documented with its measured size (the 50-house grid: 141.8 m, X at 1 kHz with an inductive PEN −21.6 / −18.9 %, carson_series / sommerfeld); the plan records per cabinet which rule placed it and the gap it compared (PlannedSite.cabinet_rule, PlannedSite.centroid_ray_gap_m). Over the 80 AP1 mixes 118 groups stand 20.21 … 53.56 m from their houses on the centroid ray and take the far-end ray; the largest gap kept is 18.84 m. end_clearance_m must be smaller than max_far_end_gap_m. Golden: nothing moves.

Verification audit W1R3 of the W1R2 fixes

A third round checked the fixes of fw1r2sol (snapshot 8c83d7c). Its own integration of the documented readings agreed with the code on 1740 piece pairs to 5.5e-12 wherever the code claims a reading. Findings:

  • W1R3-01 (medium): the length gate of the tilted rule kept the old drift for longer pieces: a core crossing the shield's axis stepped by −8.6e-5 of the loop at the gate, shield pieces of mixed length −1.6e-3, where the texts said about 1e-6.
  • W1R3-02 (low): the cap |cos φ| ≥ 0.99 made a new step of 1.5e-3 at 8.1° for two wires leaving a junction in 0.02 m pieces.
  • W1R3-03 (medium): the chord rule took quadratic time: 4000 collinear edges 13.3 s (0.085 s before W1R2-05), a 2 km polyline electrode in 1 m vertices 17.7 s (0.46 s).
  • W1R3-04 (low): a row of Numbers that change said "more than" 0.46 µm, where the rule changes polylines whose vertices lie closer than that.
  • W1R3-05 … W1R3-07 (info): correct but undeclared moves (wires leaving a junction at 3° in fine pieces +0.098 / +0.75 %, drops routed back along a split main +6.8e-5 … +1.65e-3); the partition into runs depends on the vertex order at UTM coordinates (2.4e-8); the carson_series gap between a lumped tilted pair and its pieces grows with the square of the tilt (4.2e-4 … 4.4e-3 in X at 2e-3 … 8e-3 rad).

Taken up by fw1r3 (01, 02, 03; 06 measured), the coordinator's texts (04, 05) and stream w3perf of wave 3 (07).

Stream fw1r3: fixes of audit W1R3

  • Tilted rule: no length gate and no angular cap; pairs within 1e-9 of orthogonal count as orthogonal. Every case of the audit adds up within 2.2e-12, the tilted coax within 6.4e-12 for tilts up to 1e-3 rad (an unmarked touching pair within 3.1e-10), and the solved loop within 1.1e-15 under perfect_mirror (sommerfeld within 1.6e-8, its own piece dependence).
  • Chord rule in linear time: the decisions are the same bit for bit, and the runs are cached on the vertices' values: 4000 collinear edges 0.006 s, the 2 km polyline electrode 0.25 s instead of 17.3 s. The order dependence of W1R3-06 stays at 2.37e-8.
  • Golden: strict against the stream's own baseline, 49 cases pass; of a probe of 178 arrays 177 are bit-identical, and two wires leaving one point at 30° in 0.05 m pieces move from −1.04e-4 to −7.8e-16 off their lumped pair. Every generated network is bit-identical.

Wave 2: impressed voltage sources, shells in mom, projected coordinates

Wave 2 added impressed voltage sources (stream w2src, finding 10.51, the open item "voltage sources" of the scope of 2026-11-14) and concrete shells in the moment method, together with solves at projected coordinates that do not depend on where a world stands (stream w2mom, an open point of fw1sol). Decisions D1 and D5 came with its fixes.

Stream w2src: impressed voltage sources (10.51)

A VoltageSource holds attached_to at U above return_to (or remote earth) and is solved by modified nodal analysis: one current unknown and one constraint row per source in the nodal system of the shared pipeline, in image, image_2layer (also on the cross-layer path), mom and mom_sommerfeld, with conductors, inductive coupling and several frequencies. Up to 0.15.0 every backend dropped it with a warning and solved to zero potentials. In short:

  • Results: SourceRecord.current holds the solved current (new SourceRecord.voltage and column voltage_v), input_impedance() is U/I, and sweep, the rho-f helpers, split_factor and touch_voltage_spectrum accept the source; several sources superpose and 0 V is an ideal short; new capability BackendCapabilities.voltage_sources.
  • Checks: voltage sources that close a loop through ideal bonds or remote earth, and a source short-circuited by an ideal bond, raise ValueError naming the sources; fem rejected voltage sources with BackendCapabilityError until its conforming models of wave 4, which solve them.
  • Validation: the voltage solve equals the 1 A current-source solve scaled by U/Z_in in every backend, in two- and three-layer soil, on the cross-layer path and with inductive conductors at 0 / 50 / 1000 Hz (at most 1.4e-15), and agrees with solve_mutual_matrix for a two-terminal source, the hand-inverted transfer matrix of three sources, Dwight's rod (−0.012 %) and the hemispherical far field.
  • Golden: no stored quantity moves; worlds without voltage sources are bit-identical.

Stream w2mom: concrete shells in mom and mom_sommerfeld, solves at projected coordinates

  • Shells: each segment adds its radial shell resistance C/Δs to the diagonal of the point-matching system and the shell drop to its potential; with one owner per segment the image family solves the same system (7e-16), and a ring rises by exactly C/(2πr) in one, two and three layers (1e-14). Up to then both engines raised BackendCapabilityError; fem remained the only backend that refused shells, until wave 4. mom is thereby the per-segment reference for encased foundations: the image family's point kernel lies +0.35 … +0.69 % above it for grids in 5 cm of wet concrete and up to +18.8 % for stars.
  • Projected coordinates: a world with a horizontal coordinate beyond 10 km is solved in an exactly shifted local frame and reported in user coordinates, also by FieldResult.potential, and the segment counts allow the round-off of the coordinates' own magnitude (64 ε|x|): a generated 10 m mesh foundation at UTM coordinates had 508 instead of 440 segments, and mom / image(kernel="point") moved by 2.6e-4 / 2.8e-4, now 3e-12; the line kernel stayed within its own spread (1.5e-6; ≤ 5e-11 since decision D2). A distributed conductor whose length is a whole number of pieces up to round-off gets no extra piece (a 60 m counterpoise at UTM coordinates 7 → 6 pieces).
  • Golden: nothing moves; the AP1 catalogue is not affected. Three open points went to the audits: the knife edge of the line kernel's switch (D2), worlds that mix coordinates (D5) and the brace effect with mom.

Audits W2A and W2B of the wave-2 streams

Two auditors attacked wave 2 (snapshot ecff7b6, change from 1579ed8), W2A the voltage sources, W2B the shells and the frame. Findings:

  • W2A-01 (medium): LvNetworkLayout.measured_grounding_impedance and verify_current_balance fell back to 1 A for a voltage source (5.604 instead of 1.635 Ω, balance ok=False).
  • W2A-02 … W2A-09 (low): compare_engines left out the input impedance of voltage sources; the alias _warn_ignored_sources lost its stacklevel (TypeError in every world); a voltage record without voltage and current gave [] or IndexError; "equals the scaled 1 A solve" holds for one source only (two sources −7.5 %); the messages of a same-node voltage source and of a loop; a direct solve_fem and the shell refusal of fem named the wrong capable backends.
  • W2A-10, W2A-11 (info): source_kind="voltage" with a measurement set-up solved, but measured_impedance refused it; a bullet of this page and notebook 83.
  • W2B-01, W2B-02 (medium): the near/far switch of the line kernel is a knife edge: two-layer image pairs on it spread Z by 1.0e-5 … 2.6e-5 and the touch voltage by up to 5.5e-5 with the position of a world (the texts said up to 2.4e-7), also through the series-image switch, whose far form is the point form; the estimate of D2 (about 2e-7) was wrong (golden line_img2_rod_crosslayer 1.15e-5).
  • W2B-03 (medium): "worlds within 10 km unchanged" is false for distributed conductors: a 60 m / 10 m counterpoise goes 7 → 6 pieces in 876 of 3600 directions, Z −0.30 % (image) and −2.54 % (mom).
  • W2B-04 (medium): decision D5 quantified: the round-off grows only from 1.0e-11 to 1.5e-11 (point kernel), but nothing warns; a return electrode given at local coordinates raised Z_in by 0.43 %, a cable end given locally made a 33 118 km conductor (7.5 kΩ instead of 5.4 Ω), and sommerfeld did not finish.
  • W2B-05 (medium, pre-existing): one lumped Neumann conductor under sommerfeld took 0.42 / 4.3 / 28 s and 116 / 364 / 1647 MB at 0.25 / 1 / 2 km.
  • W2B-06, W2B-07 (low, texts): the brace effect with mom and the medium_industry values were missing from the concrete-shell page; "mom_sommerfeld equals mom to 4e-9" holds for one soil only (1.4e-9 … 1.5e-8 over four).
  • W2B-08 (info): the frame shift is exact only for coordinates between o/2 and 2o, o being the frame's origin; elsewhere it is within 1.9e-9 m.

Confirmed: the modified nodal analysis matches the scaled 1 A solve and independent closed forms to 1.1e-15 in every backend, layering, terminal kind and frequency tested; worlds without voltage sources are bit-identical (563 of 563 golden quantities) and cost the same; the shell term and the frame agree with two independent methods each to round-off (the rise C/(2πr) of a ring to 5.6e-15; 19 worlds at 10 offsets: Z within 2.6e-11). Taken up by fw2src (W2A-01 … -10, with D1), fw2mom (the texts of W2B-01, -03, -04 with D5, -06 … -08), stream w3xl of wave 3 (W2B-01, -02 by D2), stream w3perf (W2B-05) and the coordinator (W2A-11).

Streams fw2src and fw2mom: fixes of audits W2A and W2B, decisions D1 and D5

  • fw2src (D1): VoltageSource.internal_resistance_ohm and internal_inductance_h (≥ 0, 0 by default: the ideal source, bit for bit) and internal_impedance(f); Z_q is the diagonal entry of the source's constraint row in every backend that solves voltage sources, and input_impedance() is the impedance the source sees, U/I − Z_q. A galvanic world whose source has an inductance is solved per frequency on the complex path. Validated against the junction + lumped_series_resistance_ohm pattern (≤ 7.2e-16), the 1 A solve with I = U/(Z_q + Z_in) in every backend, three earth models and the cross-layer path (≤ 4.0e-15), and the transfer matrix of three sources and solve_mutual_matrix (≤ 3.4e-16). A source with R > 0 opens a loop of voltage sources; an inductance alone does not.
  • fw2src (W2A): the layout readings use the solved current (1.635 Ω); a record without voltage and current raises ValueError; stacklevel is restored; the loop message names the sources on the loop, and a same-node voltage source is reported as short-circuited; compare_engines compares the input impedance of voltage sources; source_kind="voltage" gives the readings of "current". Golden: 563 of 563 quantities identical; worlds with ideal voltage sources bit-identical.
  • fw2mom (D5, W2B): diagnose() has the category coordinates (a warning when points lie both within 10 km of the origin and beyond 1000 km from it, naming both groups and the conductors between them; information for a world wider than 100 km that does not mix), and such a solve warns once with MixedCoordinatesWarning before anything is discretised. The texts give the measured line-kernel spread (W2B-01), the local piece counts with W2B's pin test (W2B-03), the brace effect with mom (+49.6 / +321.2 % for the house mesh, +49.5 / +313.7 % for medium_industry at ρ_c = 1000 / 5000 Ω·m; the owner model with bare braces 1.6 / 2.8 % and 2.2 / 3.6 % high), the agreement of mom_sommerfeld with mom (about 1e-8), and where the frame shift is exact. Golden: 563 of 563 quantities identical.

Audit W2R2: round 2 on the wave-2 fixes

The second round attacked the fixes of fw2src and fw2mom (snapshot 34ad269). D1 holds (the constraint row, its sign and the per-frequency complex path agree with independent methods to round-off; ideal sources stay bit-identical), the W2A fixes hold, and D5 raised no false alarm in eleven projected and local coordinate systems while it caught every stray node or conductor end of a UTM world; worlds outside the items are bit-identical (563 of 563). Findings:

  • W2R2-01 (low): worlds and results pickled before D1 raised AttributeError.
  • W2R2-02 (low, cost): a galvanic mom world whose source has an inductance got one complex factorisation per frequency (×2.0 / ×8.1 / ×28 at 1 / 5 / 20 frequencies, 1488 segments).
  • W2R2-03 (low, text): the stated direct-pair spread of the line kernel was exceeded (a 12 m strip 5.9e-7 / 1.15e-6).
  • W2R2-04, W2R2-05 (low): the message of a short-circuited source with R > 0; measured_impedance raised "2 sources" for a result with one voltage and one current source, which read the current source before.
  • W2R2-06 … W2R2-11 (info): "never flagged" is untrue for wide pure worlds; a TN network with its substation at UTM coordinates builds a mixed world (D5 warns, correctly); "876 of 3600" depends on how the angles are formed (829); mom_sommerfeld against mom is 9e-8 with the interface 0.2 m below the wires and 9.2 % with a truncated series (both warned); a large R loses log10(R/Z_E) digits, and 1e-310 Ω gave nan; what the D5 rule does not see (a stray point between 10 and 1000 km, field and probe points).

Taken up by fw2r2, the known-limitation texts through the coordinator.

Stream fw2r2: fixes of audit W2R2

  • Pickles: worlds and results pickled before D1 load as ideal sources (W2R2-01).
  • Cost: a galvanic mom / mom_sommerfeld world whose source has an inductance factorises its segment system once and solves only the V × V system of the source currents per frequency (exact): 1.02 times the solve without the inductance at 20 frequencies on 1 488 segments, 28 times before; results equal to 3.3e-15 (W2R2-02; audit W3B: within 1.4e-14 of the former path, ×1.04 … ×1.05).
  • Messages and readings: a short-circuited source behind Z_q is told that its current U/Z_q would circulate through the bond and the source; measured_impedance and the layout readings take the single current source, else the single voltage source, as up to 0.15.0 (W2R2-04, -05). A non-zero R or L below the smallest normal float is rejected (W2R2-10), and SubstationConfig.position is documented as local (W2R2-07).
  • Texts: the line-kernel spread, the scope of D5, the 829 … 876 directions and the agreement of mom_sommerfeld (W2R2-03, -06, -08, -09); the text on what D5 does not see (W2R2-11) went to the known limitations.
  • Golden: 563 of 563 quantities identical.

Wave 3: the two-layer image series, earth return and soil

Wave 3 took the roadmap items of the two-layer image series and the cross-layer path with decision D2 (stream w3xl), and those of the earth return, the soil and the BusType document with the user decisions Q34 and Q39 (stream w3perf). The author decided the far-image option and D9 during its fixes.

Stream w3xl: far images, the cross-layer path in line form, memory, the continuous switch (D2, 10.28, 10.56)

Five items. In short:

  • Far images (item 1): far Tagg/Sunde images carry the quadrupole term of the segment average, and the far form of segment pairs the radius term of the reduced kernel; the term is tapered off between 60 and 120 segment lengths of the pair's vertical distance and left out below 1e-9 of a unit point term. A straight strip in two-layer soil is within 3.6e-6 of its uniform-current resistance for segment lengths of 0.125 … 2 m, not monotonically (+5.1e-4 before; the 7.7e-7 of the stream held at its five sampled lengths only, audit W3A-03), and the surface potential above it within 8e-6 (0.94 % before).
  • Cross-layer path (items 2–4): the layered correction in line form (its exact image expansion, ADR-0007 amendment): a rod through the interface changes by 9e-7 between segment lengths of 2 and 0.125 m (1.3e-4 … 2.4e-4 before), and the two paths of image_2layer agree to 1.7e-7 where both apply (6.2e-4). Memory as on the series path, in row chunks and in row blocks beyond the budget: 278 → 137 MiB at the AP1 station with 40 % penetration with numba (without numba 224 → 140 MiB since audit W3A-05). The spectral amplitudes in closed form: the path with the point kernel 1.6 … 2.0 times faster at the AP1 station, round-off.
  • Continuous switch (item 5, D2): pairs between 6 and 7.5 segment lengths blend the exact and the far value with a C¹ weight (direct pairs, surface and Tagg/Sunde images, the images of the cross-layer correction, field points): 1e-13 over local shifts and ≤ 5e-11 at UTM coordinates (4.7e-11 measured by audit W3A-04), where the position had moved results by up to 5.9e-7 (direct pairs) and 8e-6 … 2.6e-5 (two-layer images).
  • Numbers: homogeneous soil ≤ 7.8e-7; two layers: house grids 3e-6 … 1.8e-4, wires near the interface up to 6.2e-4 (audit W3A-04), surface potentials near the interface up to 0.9 %; cross-layer rods ≤ 4e-4, the AP1 station −4e-5. The cost was larger than the stream stated (audit W3A-01, see fw3xl).
  • Golden: 60 quantities in 9 line-kernel cases declared (w3xl.toml), up to 6.0e-4 (line_img2_ring_rods_within_layer); line_img2_rod_crosslayer moves 4.0e-4, its former point-form error. Point-kernel and mom-family cases are bit-identical apart from the round-off of the closed-form amplitudes (≤ 2.5e-16).

Stream w3perf: penetration depth, sommerfeld segment rules, the BusType preset, overlaps (Q34, Q39)

Roadmap items of the earth return and the soil, the user decisions Q34 and Q39, and two audit leftovers (W2B-05, W1R3-07). In short:

  • Penetration depth: penetration_depth(soil, frequencies) and PenetrationDepth give the complex penetration depth and the equivalent resistivity of a soil with any number of layers; exact for homogeneous soil, over the 39 AP1 soils (50 Hz … 1 kHz, 0.1 … 1000 m) within a median of 2.2 % of the exact layered earth return (at most 28 / 33 % overhead / buried); three and four layers up to 46 / 77 % at 1 km and 1 kHz (audit W3B-08). per_metre_mutual_impedance gives the exact layered earth-return impedance per metre (within 5e-8 of Carson and of the two-layer Pollaczek integral; against an independent integral within 6e-8 of the earth-return correction up to 300 m and 7e-7 at 1 km for buried pairs, audit W3B-08).
  • Q34: the self term of every sommerfeld segment is the exact one-dimensional reduction of its double integral, and close pairs get a graded rule: no step at a quarter skin depth (4.8e-4 off before, with a step of 3.5e-4); with the λ grid of audit W3B-01 the self correction is within 1.1e-9 for the soils tested (3.4e-9 in high-contrast soils, audit W3R2B-08) and close pairs within about 4e-8 (the stream had stated 2.7e-9; up to 1.5e-3 before).
  • Q39: BusType documents record the effective-resistivity preset (rho_preset= of the exporters, metadata["rho_preset"], BusTypeSpec.rho_preset); evaluate_spec and bustype_from_spec warn with RhoPresetMismatchWarning when the bus uses another preset.
  • Overlaps: diagnose() reports inductive conductors that lie beside each other closer than touching over more than ten touching distances and 5 % of the shorter one (category overlap); the generated networks had such pairs (the 5-house radial network 10, 200 houses 247: drops of one tap on one axis), which led to decision D9.
  • Cost: a long lumped conductor under sommerfeld costs at most linear time with bounded memory (W2B-05: 2 km 28 s and 1.6 GB → 1.1 s and 0.21 GB; 100 km 10.6 s within 0.24 GB, but beyond 33 km for that conductor, 38 km for one at 0.7 m, the result warns with SommerfeldResolutionWarning and is not converged, audit W3B-10). Compiled Carson integrals were measured and not built (5 … 13 % of an inductive sweep after memoisation, below the 20 % threshold; 10.63).
  • carson_series: a tilted near-parallel pair that comes close is tiled per stretch (W1R3-07: a lumped pair and its pieces within 8e-6 of the loop reactance); generated networks move by up to 3e-7 (audit W3B-07). On the generated networks of 5 … 100 houses the series reads X 4 … 21 % and R up to 11 % high at 1 kHz and X 21 … 50 % and R up to 0.9 % high at 50 Hz against sommerfeld (audits W3B-02, W3R2B-03).
  • Golden: five cases move by 8e-10 … 4.9e-7 (cond_lumped_long_pen_sommerfeld 4.9e-7, cond_isolated_pen_sommerfeld_two_layer, cond_overhead_lead_over_pen_carson_series, cond_galvanic_neumann_sommerfeld, defaults_mixed_cluster_inductive).

Audits W3A and W3B of the wave-3 streams

Two auditors attacked wave 3 (snapshot 0b942c9), W3A stream w3xl, W3B stream w3perf together with the fix streams fw1r3 and fw2r2. Findings:

  • W3A-01 (medium): the image work grew with the world's longest segment and with the image density: eight 9.4 m pieces among 1920 segments made the solve 2.7 … 6.5 times slower, thin top layers 7 … 8.5 times, and the TN 40-house network in 1000/30 Ω·m with h₁ = 1.5 m took 4.4 times (11 times without numba) the solve before wave 3, where the texts said +59 … +70 % and 3.3 times.
  • W3A-02 (medium, pre-existing): image pairs used the reduced kernel √(r² + a²): a ring 1 cm above a 1000/30 Ω·m interface read +1.60 % against the exact thin ring (+1.74 % before wave 3); the cause of what stream w4axi had found.
  • W3A-03 … W3A-06 (low): the strip bound "within 7.7e-7, monotonically" held at the five sampled lengths only; stale texts on the one-step switch and on far images as point sources, 6.2e-4 instead of "up to 4e-4" and 4.7e-11 instead of 3e-11 at UTM coordinates; the memory claims held with numba only (161 instead of 79.6 MiB); the near-interface "finer segment_length" warning fired for the line kernel.
  • W3A-07 (info): switching the quadrupole term off did not give the code before wave 3.
  • W3B-01 (low): the Q34 bound failed for short segments (1e-5 … 7.4e-5 at 0.01 skin depths, 7.5e-5 … 3e-4 at 1 m), because the logarithmic region of the λ grid had 64 nodes; pre-existing, at most 8e-9 in a solved reactance; the close rule 3.5e-8 off instead of the stated 2.7e-9.
  • W3B-02 (medium, text): carson_series on generated networks of 5 … 30 houses reads X +3.6 … +20.7 % and R +1.9 … +7.8 % at 1 kHz and X +21 … +44 % at 50 Hz, which no text stated.
  • W3B-03 (low): the overlap check had no tolerance: cables 1e-14 m inside the touching distance were flagged over their whole length.
  • W3B-04 (info, decision): drops of one tap in a row at the touching distance move the 5-house radial network's X at 1 kHz by −2.0 / −2.7 % (decision D9).
  • W3B-05, W3B-07 … W3B-09 (low, texts): star networks warn too, and the stream's limitation and roadmap texts were not taken over; the stretch tiling moves generated networks (the 10-house star with sites 2.8e-7, the 80-house radial network 3.4e-8); the errors of penetration_depth in three and four layers (44 … 77 % at 1 km, 1 kHz) and per_metre_mutual_impedance 6.8e-7 off at 1 km for buried pairs; rows 34 and 39 of this page.
  • W3B-06 (low): to_bustype and save_bustype_to_db validated the preset and dropped it.
  • W3B-10 … W3B-12 (info): the 100 km conductor warns as unconverged, and so does one of 37 km; the mutual of two long close conductors moved by 2.6e-5 … 4e-5, not 8e-6; penetration_depth read "50" and True as frequencies and raised ZeroDivisionError at 1e-320 Hz, and PenetrationDepth could not be compared or hashed; a proposed test of audit W2R2 reads a phrase that D2 removed.

Confirmed: the blend is continuous; translation invariance holds (7.7e-14 over local shifts, 4.7e-11 at UTM coordinates); the cross-layer rod is within 1.6e-6 of an exact closed form; chunking is bit-identical; golden 497 quantities identical, 6 within round-off, 60 moved within their bounds; the jump of a ring on an interface that w4axi found is resolved (≤ 0.0005 %). penetration_depth agrees with the auditor's own reflection coefficient to 1.8e-9 in one to four layers; Q34 has no step (≤ 6.5e-12 over 6700 lengths); W2B-05 is bounded (2 km: 1.22 s, 0.21 GB); fw1r3 and fw2r2 are bit-identical in the golden cases and right in the auditor's own attacks (pieces against the lumped pair ≤ 4.6e-15; W2R2-02 within 1.4e-14 of the former path). Taken up by fw3xl (W3A, with the far-image option), fw3perf (W3B-01 … -08, -10, -11; -04 with D9) and the coordinator (W3B-09, -12).

Streams fw3xl and fw3perf: fixes of audits W3A and W3B, the far-image option and D9

  • fw3xl (W3A-01, -05): the far-image work follows the pair class and the upper half of the symmetric matrix (bit-identical, round-off in the symmetric half): 16 house grids take 3.8 times the point kernel in homogeneous soil and 1.6 times in two-layer soil (h₁ = 5 m) with numba (5.8 and 1.4 times without); against the solve before wave 3 the TN 40-house network takes 1.84 times with numba and 3.63 times without (4.2 and 9.7 times before the fix), eight 9.4 m pieces among the 16 house grids 1.5 times (2.8), thin top layers 3.6 … 4.5 times (7 … 8.7). Without numba the far-image term holds 80 instead of 161 MiB.
  • fw3xl (W3A-02, -03, -04, -06): image pairs act at the transverse distance max(ρ⊥, a), collinear images and images within one wire radius of their segment keep the reduced kernel, far images have no radius term, and the image corrections are symmetric: the ring 1 cm above 1000/30 Ω·m −0.004 % instead of +1.60 %, a strip 0.1 m above the interface −3.8e-6 instead of +6.8e-5, the rod through the interface within 1.4e-6 of its exact value. The near-interface warning fires for the point kernel only; the texts are corrected.
  • The far-image option (the author's decision of 2026-11-15): Engine.image_far_field = "point" keeps the far Tagg/Sunde images and the images of the cross-layer correction beyond the near-pair reach as point sources, the continuous switch and the transverse distance stay; networks move by 2e-5 … 1.8e-4 against the default (16 house grids 0.4 m above a 1000/10 Ω·m interface 4.25e-4, audit W3R2A-04), surface potentials by up to 0.8 %, and the TN 40-house network solves in 0.46 of the default's time (0.84 of the solve before wave 3); recorded in metadata["series"]["far_field"]. Since stream fw3r2a the point form keeps the near image pairs on the cross-layer path: networks 3e-6 … 4.3e-4, the TN 40-house network 0.49 of the default's time and 0.91 of the solve before wave 3.
  • Golden (fw3xl): W3A-02 moves four cases by at most 3.2e-7 (line_img2_ring_rods_within_layer; 3.19e-7, audit W3R2A-07); the other fixes and the option are bit-identical in every stored case.
  • fw3perf (W3B): the logarithmic region of the λ grid has 256 nodes: the self term is within 1.1e-9 of a refined rule and an independent reference from 1 m and 0.01 skin depths to 3 km, close pairs within about 4e-8, at no measurable cost. The overlap check allows round-off at the touching distance, and find_close_wires calls such wires close; the live BusType keeps the preset as the last line of its description (groundfield rho_preset: <name>, read back by bustype_rho_preset); penetration_depth refuses bool, str, complex and subnormal frequencies, and PenetrationDepth compares by value and is hashable; texts of W3B-02, -05, -07, -08, -10. Golden: the five sommerfeld cases move by 4.8e-18 … 2.2e-11.
  • fw3perf (D9): service drops that leave one tap in one direction lie side by side at the touching distance, sorted by length and centred on their former axis, so that only neighbours touch (PlannedBranch.axis_offset_m): X at 1 kHz of the radial 5-house network −2.33 / −2.70 % (carson_series / sommerfeld), radial 10 −2.31 / −2.82 %, star 10 −1.06 / −1.27 %, radial 80 / 200 ≤ 5e-4, radial 30 ≤ 1.1e-6; no golden case moves.

Audits W3R2A and W3R2B: round 2 on the wave-3 fixes

W3R2A attacked fw3xl and the far-image option (snapshot ac556ec), W3R2B fw3perf and D9 (snapshot df16521). Findings:

  • W3R2A-01 (medium): with image_far_field="point" wires wholly below the layer interface lose accuracy as their segments get longer: a 75 m strip below a 0.5 m top layer reads −1.0e-3 … −1.8e-3 at 2.5 m segments, −1.7 … −4.6 % at 7.5 m and up to −58 % at 37.5 m against an exact reference (the default within 1.3e-6); 16 house grids with a 75 m bare conductor in 40 m pieces +1.13 % against the default.
  • W3R2A-02 (low): far_field of the public solve_image_2layer is not validated; any other value runs the point form, and the field then disagrees with the solve.
  • W3R2A-03 (low): within one wire radius of the interface Z is not monotone in the gap (a ring in 1000/30 Ω·m: 5.993 → 7.319 → 5.992 Ω).
  • W3R2A-04 (low, texts): "the point form moves networks by 2e-5 … 1.8e-4" is too narrow (4.25e-4), and "as before wave 3" is misleading (up to 2.3e-4 from the D2 blend, which the option keeps).
  • W3R2A-05 … W3R2A-07 (info): "integrated exactly" overstates the axis value for short strips near the interface (a 2 m strip 5 mm above 1000/30 Ω·m +3.0e-4); direct pairs of different wires keep the reduced kernel (two strips 1 cm above the interface, 5 cm apart, −3.5e-4); a bound comment in w3xl.toml (3.4e-7 against the measured 3.19e-7).
  • W3R2B-01 (medium): the D9 rows held only to 1e-11 m: any placement jitter from 1 nm to 1 mm put the drops back on one axis (the 10-house radial network: 19 / 20 / 14 overlaps), and X at 1 kHz jumped by +2.37 % / +2.90 % (carson_series / sommerfeld) at 1 nm.
  • W3R2B-02 (low): the overlap tolerance of 1e-11 m lies below the spacing of floating-point numbers at projected coordinates: rows translated to (5e5, 5.8e6) give 4 / 10 / 98 false overlaps for the radial networks of 5 / 80 / 200 houses.
  • W3R2B-03 (medium, text): the stated carson_series error is exceeded (the 80-house radial network +49.7 % at 50 Hz; R up to +11.1 % at 1 kHz and 0.9 % at 50 Hz; the default sommerfeld 1.0e-3 from a refined one, stated 4e-4).
  • W3R2B-04 (low, text): the base error of a 1 m self term is 3.0e-4 / 6.4e-4 in 30/1000 and 10/10 000 Ω·m, not 7.5e-5.
  • W3R2B-05 (info): a PenetrationDepth built directly is not validated, and f = +0.0 and −0.0 compare equal but hash differently.
  • W3R2B-06 (low): loading refused only blank presets ("station\nfoo" lost the preset, " station " read back as "station", unknown names passed), and every user line that merely starts with the marker was deleted.
  • W3R2B-07, W3R2B-08 (info): the start points of a row leave their tap by up to (n − 1)/2 touching distances, and stars of 40 … 180 houses have rows too (the 60-house star X −1.0e-3); the self-term bound of 1.1e-9 reaches 3.4e-9 in 10/10 000 Ω·m and 1.8e-9 under a 0.3 m top layer.

Confirmed: the paths of the option (round trips, several frequencies, solve_mutual_field, no effect with the point kernel, the mom family or homogeneous soil); with D2 and W3A-02 switched off at run time the point form reproduces the code before wave 3 to 6.6e-7 in the upper layer and 5.7e-6 on the cross-layer path; the W3A-01 matrices are bit-identical but for the diagonal rule (Z −5.4e-14); W3A-02 against the auditor's exact references (strips with a gap of at least one radius ≤ 5.5e-5, the ring −0.0039 %, reciprocity ≤ 4e-11). The D9 geometry of 80 AP1 networks and 58 variants: every conductor that is not a row drop, every electrode and every junction bit-identical, the rows equal to the auditor's own construction, up to 277 overlaps → 0 without jitter, old plans rebuilt bit-identically; the D9 moves agree between three constructions; W3B-01 holds (self terms within 1.1e-9 for the stream's soils, close pairs 3.5e-8), golden 43 cases bit-identical and 5 within 4.8e-18 … 2.2e-11. Outside the round, W3R2B found that plan() followed by build() drew the placement jitter again and that a tie of the star topology flips under jitter (the 10-house star: X −11.8 %, now on the roadmap). Taken up by fw3r2a (W3R2A), fw3r2b (W3R2B-01, -02, -05, -06, the texts of -03 and -07, plan() / build()) and the coordinator (the texts of W3R2B-04, -08).

Stream fw3r2a: fixes of audit W3R2A

  • The point form below the interface (W3R2A-01): on the cross-layer path image_far_field="point" keeps every image family with all its images; the near pairs within 7.5 segment lengths are Galerkin integrals blended into the point form, a segment's own image follows the switch of every pair, and only the dense far term stays out. The 75 m strip below a 0.5 m top layer is within 1.1e-5 of its exact value at every segment length (−1.06e-5 at 0.5 m in 1000/30 Ω·m, the option's own far-pair error; −3.1e-7 at 37.5 m, where it read −58 %), and 16 house grids with the 75 m conductor in 37.5 m pieces read −3.65e-6 against the default instead of +1.13 %. The default and the series path in point form are bit-identical.
  • Its cost: on cross-layer worlds the point form takes 0.49 … 0.94 of the default's time; below thin top layers it keeps the Galerkin near image pairs it used to save (1.5 … 2.4 times the solve before wave 3 instead of 1.2). The TN 40-house network in 1000/30 Ω·m with h₁ = 1.5 m is a cross-layer world (its transformer rods reach below h₁): its point form moves by 2.3e-4 and takes 0.91 of the solve before wave 3 (0.83 before the fix).
  • far_field (W3R2A-02): solve_image_2layer, the series kernel, the image families and the field correction raise ValueError for any value but "quadrupole" or "point".
  • Within one wire radius (W3R2A-03): the image blend runs over a tenth of the wire radius; the bump of 22 % of the ring in 1000/30 Ω·m is gone, and a step of at most 0.17 % onto the interface remains (wires 0 < g < a/2 from the interface move by up to −18 %: the ring 1.75 mm above, 7.319 → 5.985 Ω; the ring 1 cm above stays at −0.004 %).
  • Texts (W3R2A-04 … -07): the point form moves networks by 3e-6 … 4.3e-4 against the default (16 house grids 0.4 m above a 1000/10 Ω·m interface) and is not the result before wave 3 (16 grids in 1000/30 Ω·m, h₁ = 1.5 m: +2.32e-4); the line kernel is exact for long wires with an end effect O(a²/(d·ℓ)) (a 2 m strip at one wire radius +3.03e-4); direct pairs of different wires keep their convention (−3.50e-4 against a circumference-averaged direct term); the golden comment gives 3.19e-7.
  • Left open (before the stream as well): in point form a ring at the interface differs by up to 2.96e-4 between the series and the cross-layer path (the default by 1.3e-6), and solve_mutual_matrix(symmetrize=False) of a cross-layer world is asymmetric by 2.3e-8 in both forms.
  • Golden: 563 of 563 quantities identical; 29 new tests.

Stream fw3r2b: fixes of audit W3R2B

  • Rows under jitter (W3R2B-01): two drops of one node belong to one row when their start points lie within the touching distance d_t of each other and the shorter drop's end lies within d_t of the longer drop's line; drops that are not exactly parallel lie along one common normal (PlannedBranch.axis_offset_normal_xy), each at least d_t from the others, and a drop that would overlap a drop of a row joins it, also a drop of a tap 1 … 4 cm away on the same trunk (from 2 cm of jitter). The 10-house radial network at 1 nm of jitter: −8.5e-10 / −1.1e-9 instead of +2.4 % / +2.9 %; no generated network reports an overlap with jitter_m 0 … 0.1 m (240 networks, star and radial, 5 … 200 houses); every network without jitter is bit-identical.
  • Projected coordinates (W3R2B-02): the tolerance at the touching distance is the larger of 1e-9 of it and 16 units in the last place of the pair's largest coordinate; local worlds keep their findings bit for bit.
  • Values and documents (W3R2B-05, -06): a PenetrationDepth built directly is validated and its hash agrees with ==; metadata["rho_preset"] must be a known preset name or null, and only exact preset lines of a description are removed or replaced.
  • plan() and build(): build() right after plan() on the same generator gives the world of that plan; successive calls still draw successive realisations.
  • Golden: 563 of 563 quantities identical.

Wave 4: a conforming fem (Q37, Q40, D6)

Wave 4 replaced the equivalent-hemisphere reduction of fem by conforming finite-element models (user decision Q37): an axisymmetric model (stream w4axi, part A) and a three-dimensional model for every other world (stream w4fem3d, part B), which also quantified the overlap of concrete shells at junctions (Q40). Its dependencies follow decision D6.

Stream w4axi: the conforming axisymmetric model (part A)

Rods on one vertical axis and horizontal rings centred on it are solved as the solid bodies they are (a cylinder with flat end faces, a torus), in any number of horizontal layers, bare or with a concrete shell, each electrode one port: linear triangles on a graded tensor mesh conforming to every electrode surface and layer interface, an O-grid around the ring wire, the monopole Dirichlet-to-Neumann condition on a box 1000 lengths away, and the port conductance matrix extrapolated from two nested levels; no new dependency. The network of the shared pipeline runs on top. In short:

  • Accuracy: within about 1e-4 of independent references (thin-wire limits, elliptic and Hankel rings, finite volumes of the solid rod) at 0.2 … 2 s per solve; the limit cases of the reduction — a ring 1 cm above an interface (+191 … +308 % without a message), a rod reaching 1 µm … 8 cm into a more conductive top layer (−44 … −78 %, warning only), a ring exactly on an interface, rods through one, clusters of several electrodes and several clusters — are solved within 1e-4 (within 2e-3 by the 3-D model of part B where they are not axisymmetric; audit W4A-01 found the exception of a ring wire at an interface, see below).
  • Numbers: every fem result moves: the stored 3 m rods −4.65 % / −4.57 % (Dwight's rod ignored the head depth), the B2 rod / B3 ring −0.70 % / −0.35 %, a ring with a bonded central rod +20 %, a ring 1 cm above a conductive layer −67 %, a rod 2 cm into a conductive top layer +164 %. Every other world was refused until part B.
  • Options: FemOptions.n_radial, n_axial and z_far_factor are gone (2026.11 names); the point sources of fem count against Engine.max_segments (found in the stream's own attack); benchmark B1 checks fem against Weber's disc.
  • For image_2layer: the stream's references found a ring 1 cm above an interface 1.7 % above the exact thin ring, a jump of 0.03 … 0.38 % between the two sides for a ring on an interface, and a truncated series in 30/10 000 Ω·m (−1.0 %); wave 3 resolved the jump, and audit W3A-02 found the cause of the first.
  • Golden: fem_rod_hom −4.65 % and fem_rod_two_layer_deep −4.57 % (w4fem.toml); the other 47 cases are bit-identical.

Stream w4fem3d: the three-dimensional conforming model (part B; Q40, D6)

Every world that is not axisymmetric — strips, polylines, stars, meshes, grids, rods and rings side by side, several clusters with their transfer resistances, galvanic distributed conductors with every leaking piece a port — is solved with smoothed line sources and an analytic radius correction in an isotropic tetrahedral mesh refined towards them, partially penalised immersed layer interfaces, conjugate gradients with an algebraic multigrid, and two nested levels extrapolated. It needs the optional extra fem3d (scikit-fem, BSD-3-Clause; pyamg, MIT; decision D6) and raises ImportError naming it otherwise. In short:

  • Against part A: within 2.0e-3 for rods and rings in one to three layers, inside its own error estimate (away from interfaces and other wires since audits W4B-01, W4B-02, see below).
  • The AP1 station in the corner soils of the AP1 grid lies between the thin-wire engines: image_2layer +0.7 … +3.0 % above it, mom −0.4 … −0.9 % below; 1.5 … 3 minutes and 3.6 … 4.4 GB per solve.
  • Brace effect (the open point of w2mom): +49.09 / +317.99 % at ρ_c = 1000 / 5000 Ω·m, which confirms the per-segment value of the concrete-shell page (+49.2 / +318.5 %) to 0.1 / 0.5 points.
  • Q40: against the concrete resolved as a volume, each junction of encased wires acts like at most about one shell radius of wire (a corner −1.5 cm, a crossing −3 … −6 cm, a T-joint within ±5 cm; 5 mm bar, 5 cm cover, ρ_c 1 000 / 5 000 Ω·m); the generators' house mesh changes by less than 0.6 %, so no correction rule is applied (audit W4B-05 found these numbers not converged, see below).
  • Golden: nothing moves (every golden fem case is axisymmetric and stays on part A bit for bit); the 3-D model has no golden case.

Audit W4A: the axisymmetric model and the shared network

The first wave-4 audit checked part A and the network on top of it (snapshot 4e37760) against references without groundfield code: axisymmetric boundary elements for the solid cylinder and torus with the Tagg/Sunde images as rings, and cell-centred finite volumes of a rod with a shell. Findings:

  • W4A-01 (medium): a ring wire cut by an interface to a more conductive layer, or within 0.05 wire radii of it, is off by up to 6.0e-3 at the default; the error estimate lies below the error in 7 of 14 cases, and the levels are not monotone.
  • W4A-02, W4A-03 (low): extrapolate=False reports an error estimate of 0 for a level-0 ring 6.2e-3 low; model="auto" ends in a bare ValueError for a ring diagonal to a rod's end edge, without falling back to the 3-D model or naming a remedy.
  • W4A-04 (low): tutorial T09 still says that fem refuses every other world.
  • W4A-05 (medium): the node limit of 4 M admits about 16 GB (3.1 / 3.8 / 12.6 GB at 0.80 / 0.91 / 3.21 M nodes), and no memory figure is documented.
  • W4A-06 (low): the provenance line of the validation page names Linux and 2026-11-14 for fem rows measured on macOS on 2026-11-15.
  • W4A-07 (medium): the known limitation on rings near an interface quotes +3.6 % at 1 cm only; closer in, image_2layer reads +8.6 … +93 % (at 1.5 … 0.95 wire radii) without a warning, and diagnose() is silent.
  • W4A-08, W4A-09 (low): the dispatch threshold of 3 nm sends a rod 1 µm off the ring axis to the 3-D model (40.7 s / 2.35 GB instead of 1.8 s / 0.61 GB, −1.43e-3, and it needs the extra); stale or overstated texts ("every other world is refused", "lower bound / monotone", "within 5 %").
  • W4A-10, W4A-11 (info): predicted_nodes is 1.5 … 2.3 % low for rings; the second methods of the validation table are thin-wire models or none (the solid-body boundary elements: −1.07e-5 … −3.0e-5).

Confirmed: the default fem agrees with the boundary elements to 1.0e-5 … 1.5e-4 for rods, rings, rings near and on interfaces, rods through and near interfaces and two-port worlds, with an error estimate of 10 … 130 times the error; three layers and concrete shells against further references; the network (U = R·I to 8e-17, one branch matrix for fem and image_2layer, round trips, a UTM world and the D5 warning); the refusals, the light import and the extra; golden 559 of 563 quantities identical, the 4 that move in the two declared fem cases. Taken up by the wave-4 fixes below.

Audit W4B: the three-dimensional model

The second wave-4 audit checked part B, decision Q40 and the extra fem3d (snapshot 4e37760) against the axisymmetric model, the exact thin rings and closed forms of the smoothed line source. Findings:

  • W4B-01 (medium): the radius correction added terms for the surface image and for every wire within 20 R, where the mesh already gives the exact field: shallow wires up to +1.9e-3 high, two wires 10 cm apart +4.6e-3, above the error estimate.
  • W4B-02 (medium): neither "within 2e-3 of the axisymmetric model" nor "the estimate bounds the error" held for every world the guards accept: a ring 1.5 cm above a 1000 / 30 Ω·m interface read +9.1e-3 against an estimate of 5.4e-3, its two levels on either side of the reference.
  • W4B-03 (low–medium): at a layer contrast of 1000 the conjugate gradients did not converge in 3000 iterations and ended after about a minute in a bare RuntimeError; the pages said "any contrast".
  • W4B-04, W4B-05 (low–medium): the square concrete prism keeps the shell's outer conformal radius, but its inner one is 0.914 r_b, so its concrete leaks 3.9 % per metre more than the shell, which the texts blamed on the discretisation; the Q40 junction numbers were not converged (one face refinement moved the corner by −4.9 / −7.1 cm), although "no correction rule" stays justified.
  • W4B-06, W4B-07 (low–medium): the face key of the immersed elements aliased above 2²¹ nodes (the default limit of 2 million lies 4.6 % below) and coupled unrelated elements; results depended on numpy's global random state (1e-12 … 1.9e-6 apart), and every solve advanced the user's stream.
  • W4B-08, W4B-09, W4B-10 (low): Engine.max_segments was checked only after both levels were solved, and the number of ports had no limit; fem_peak_memory_gb reported the peak of the whole process; about 30 stale texts.

Confirmed: no stored golden number changes (563 of 563 quantities against the merge parent); the AP1 station, the brace effect (+49.09 / +317.99 %) and the Q40 numbers reproduce to the last digit; the light import, the message without the extra, the lock file, the licences and the ci: commit are correct; keeping fem experimental is justified. Taken up by the wave-4 fixes below.

Streams fw4axi and fw4fem3d: fixes of audits W4A and W4B

  • fw4axi, a ring next to a more conductive layer (W4A-01): a ring wire within 1.05 radii of an interface gets 64 instead of 8 tensor intervals per side of its mesh block. The auditor's 14 cases are within 3.3e-4 of the boundary elements (were 6.0e-3), and the error estimate (7.5e-4 … 1.9e-3) is at least the error in each of them (was below it in 7); such a ring takes about four times the nodes (0.37 → 2.3 … 2.7 s).
  • fw4axi (W4A-02, -03, -05, -08, -10): a single level reports an error estimate of NaN; auto solves a ring without room for its mesh block with the 3-D model, and model="axisymmetric" refuses it with a remedy; the common axis has a tolerance of 1e-3 of the smallest wire radius or gap (the axisymmetric reading then errs by less than 1e-6), so a rod 1 µm off a ring's axis stays axisymmetric; FemOptions.max_nodes defaults to 2 million (about 4 GB per million nodes, re-measured 3.92 … 4.21), and the node prediction errs high (+0.67 … +10.8 %).
  • fw4axi, the thin wire next to a contrasting interface (W4A-07, W4B-02): InterfaceContactWarning and the diagnose() category interface_contact for horizontal wires within the reach where the thin wire deviates from the solid wire by more than about 1 %, measured against the axisymmetric torus and the Hankel thin ring with an exact 2-D proximity correction at contrasts 1.5 … 1000 in both directions: 1.0 / 1.5 / 2.9 / 3.5 / 3.8 / 3.9 wire radii over a layer 2 / 3 / 10 / 33 / 100 / 1000 times more conductive, 1.0 … 1.25 radii over a more resistive one, nothing below a contrast of 2. Emitted by the image family, mom, mom_sommerfeld, solve_mutual_* and the 3-D fem; no generated network, no world of the AP1 soils and no golden case is reported.
  • fw4axi, texts (W4A-04, -09, W4B-10): tutorial T09 describes both models; the stale texts of the auditors' lists in the reference pages, the docstrings and ADR-0002.
  • fw4fem3d, the radius correction (W4B-01): it counts the observer's own wire whole and, of every other wire and surface image, only the part within 1.5 R (a clip at 2 R would still keep 2 % of the self term at 1.5 R). A ring r = 1 m at 0.06 … 0.8 m depth lies −1.62e-3 … −1.83e-3 from the axisymmetric model (spread 2.1e-4, was 2.1e-3); two coaxial rings 10 cm apart −1.19e-3 / −1.48e-3, inside the estimate of 3.87e-3 (were +4.60e-3 / +3.67e-3); the AP1 station moves by about −1e-4, the brace effect to +49.14 / +318.23 %.
  • fw4fem3d, the accuracy texts (W4B-02): "within 2e-3 of the axisymmetric model" holds away from interfaces and other wires; the error estimate bounds the error while the ratio of the level errors is at least 2.5 (2.1 … 2.7 times the error for rings), and not for resolved concrete. The ring 1.5 cm above a 1000 / 30 Ω·m interface still reads +9.2e-3 against 5.4e-3: the thin-wire error, which the new warning reports.
  • fw4fem3d (W4B-03 … -09): a conjugate-gradient solve that does not converge (contrast above the tested 300) raises BackendCapabilityError naming the contrast, the axisymmetric model and the integral engines (the auditor's preconditioner gave no gain); the texts say that the square prism's concrete is 3.8 % less resistive (inner conformal radius 0.914 r_b, two methods) and mark the junction numbers not converged — a few cm of wire per junction, at most about 2 r_b, sign not settled, the house mesh 0.35 … 0.85 % re-measured; faces are paired with np.lexsort; numpy's global random state is saved, seeded and restored around the multigrid set-up (results bit-identical whatever the user's seed, the user's stream unchanged); Engine.max_segments and the number of ports (100; about 0.95 s per port and level) are checked before meshing; fem_peak_memory_gb is what the solve added (about 2.9 GB per million nodes of the finer level), fem_process_peak_memory_gb the process peak.
  • Golden: 563 of 563 quantities identical in both streams.

Stream fw4int: the loose ends of the wave-4 fixes

  • The texts of fw4axi on the fem page and in ADR-0016, fitted to those of fw4fem3d; the validation rows next to and on an interface re-measured: image_2layer reads a ring 1 cm above a 1000 / 30 Ω·m interface +3.46 … +3.57 % above fem (the page said +5.2 … +5.4 %, from before wave 3), the ring on an interface within 1.2e-5 of the solid-torus boundary elements.
  • FemOptions.max_ports_3d (default 100): the port limit of the 3-D model is an option, and its refusal names it.
  • Benchmarks B8 and B10 exclude fem for its cost; measured once with the 3-D model, both are reciprocal to round-off, B10 +0.6 / +0.8 % above mom. The transfer impedance of B8 lies 0.40 … 0.96 % below mom, more than the error estimate; handed to the second audit round.
  • A test that the 3-D model warns once for a wire next to a contrasting interface; the call was already in place.
  • Golden: 563 of 563 quantities identical.

Audits W4R2A and W4R2B: round 2 on the wave-4 fixes

The second round tried to break the wave-4 fixes (snapshot 4eb1c2c) with the boundary elements of round 1, the axisymmetric model, mom refined and closed forms of the smoothed line source. Findings:

  • W4R2A-01, W4R2B-03 (medium): the 3-D model next to another wire. The fallback of W4A-03 sent a ring without room for its mesh block to the 3-D model, which read two diagonal rings 1.3 … 3.8 mm apart +11.4 … +14.3 % high against an estimate of 0.42 %, without a message; coaxial rings 7.5 cm apart, where the texts promised 2e-3, read +4.35e-3, 6 cm apart +1.0e-2, and below one source radius the port entries were off by up to 4.3 %; the radius correction counted other ports' wires with the observer's current.
  • W4R2A-02 (medium): the refined ring block held up to a contrast of 33; a ring touching a layer 1000 times more conductive read −1.61e-2 against an estimate of 1.07e-2, and at refinement=1 the estimate fell below the error at contrasts 100 and 1000.
  • W4R2A-03 (medium): the 3-D model neither warned nor refused a rod end at an interface (+43 % for a tip on a 1000 / 30 Ω·m interface).
  • W4R2B-01, W4R2B-02 (low–medium): on straight pieces longer than about 7 m off the coordinate axes the observer's own piece was clipped by round-off (a 20 m oblique strip −3.8e-4); an arm of the same polyline folded back at any angle but exactly parallel counted whole (a hairpin tilted by 1e-4 rad +1.41e-3, a 10° V +8.5e-4 against the same V as two strips).
  • W4R2A-04, W4R2A-05 (low): the reach of the near-interface warning lay 0.2 … 0.4 wire radii short for a thick wire on a small ring, and cut wires below a contrast of 2 read up to ±1.5 % without a warning; diagnose() with a fem engine reported a ring that the axisymmetric model solves.
  • W4R2B-04 … W4R2B-07, W4R2A-06, W4R2A-07 (low, info): resolved concrete with a thin cover ended in a bare ValueError after meshing; stale texts (level ratios, station memory, the junction table, the refusal of W4B-03); tests that failed on the base for the wrong reason.
  • B8 (open point of stream fw4int): the 3-D model is right; mom's floating port at the benchmark's 0.5 m is not converged. Refined to 1/32 m it falls by 0.20 … 0.75 % and ends 0.15 … 0.21 % above fem, and on a coaxial rod and ring the axisymmetric model confirms the 3-D transfer resistance to 1.3e-3.

Confirmed: golden 563 of 563 quantities identical in both audits; one near-interface warning per solve in every backend that should warn and none from the axisymmetric model; no false positive over 868 tests and the tutorials; the depth residual, the coaxial rings at 10 cm and the brace effect reproduce to the digit; the refusals of W4B-03 and W4B-08, the determinism of W4B-07 and the memory keys hold.

Streams fw4r2a and fw4r2b: fixes of audits W4R2A and W4R2B

  • fw4r2b, wires beside each other (W4R2A-01, W4R2B-03): two wires run beside each other where a point of one lies within 1.5 R of the side of the other and the two run within 30° of parallel, or where the whole of one lies within 1.5 R of another it does not meet; junctions, crossings at more than 30°, a rod on a ring and collinear pieces that meet are left alone. The model keeps such wires 1.5 R apart by a smaller source radius for the whole world and refuses them below 2.2 radii of the thickest bare wire of the world (3.3 such radii, axis to axis) before meshing, naming the wires, their distance, mom and image. Coaxial rings 4.5 … 10 cm apart lie within 1.72e-3 of the solid tori in every port entry and the bonded value, inside the estimate; 3 cm is refused by the node limit, the diagonal rings of W4R2A-01 and the ring at a rod head before meshing. The window term of another port counts only where the two wires meet; the coordinator kept this against the literal brief, since dropping it would put an L of two bonded strips 6.3e-4 below the same L as one polyline (1.0e-4 with it) without fixing any audited case.
  • fw4r2b, the own wire (W4R2B-01, -02): the axis distance comes from the cross product (the 20 m oblique strip matches its closed form to 4e-16); the own polyline counts whole only where it has turned by less than 120° (the tilted hairpin −1.9e-4, mom −2.0e-4; the jump at the threshold 1.5e-4 for 4 m arms, −1.26e-3 for 0.5 m arms, replaced in round 3 by a blend in the accumulated turn; the auditor's axis-line rule moved rings away from the solid torus and was not taken).
  • fw4r2b, the rest (W4R2B-04 … -07, W4R2A-07): resolved concrete with a thin cover is refused before meshing; the new fem_error_estimate_transfer (1.06 … 6.3 times the transfer error where the model holds; 6.3 on the coaxial analogue of B8); the B8 note says that mom at 0.5 m is not converged; the level ratios (rods 3.3 … 4.4, rings 3.0 … 3.4) and the CG refusal corrected; the W4B-01 tests fail on their base by assertion; solid_earth defaults to 2 million nodes. The AP1 station and the house mesh are unchanged to 7 digits.
  • fw4r2a, the ring block (W4R2A-02): graded towards the points where the interface cuts the wire at a narrow angle or comes closest to it, in angle and radius, from cells of 1e-3 wire radii, with 32 instead of 64 intervals. The estimate bounds the error in all 113 cases of the auditor's sweep at the default and at refinement=1; the default lies within 5.1e-5 of the boundary elements up to a contrast of 1000 (3.2e-5 at 100), at fewer nodes than before (a touching ring 151 807 nodes, 1.8 s, 0.76 GB).
  • fw4r2a, the warnings (W4R2A-03 … -05): the 3-D dispatch warns for rod ends at an interface; the reach table is re-measured on six ring geometries and covers all 2348 measured points that are 1 % off (34 lay outside the old one); cut wires are reported from a contrast of 1.4; no false positive over 741 tests, T01–T10 and 48 golden cases; diagnose() with a fem engine is silent for a world the axisymmetric model takes.
  • fw4r2a, the rest (W4R2A-06, -07): texts; a ring of radius 1.2 wire radii is solved (−7e-5 against the boundary elements) instead of refused, since no backend could otherwise.
  • New, found by fw4r2a: two mesh lines 5.6e-17 m apart (an interface at 0.3 m and a ring or rod tip at 0.1 + 0.2 m) gave a singular factor or, silently, 6809 Ω instead of 647 Ω; features within 1e-12 were one line, since audit W4R3A-01 within 1e-9 of max(1 m, x).
  • Golden: 563 of 563 quantities identical in both streams; full suite after the merge: 6137 passed, 0 failed.

Audits W4R3A and W4R3B: round 3 on the wave-4 fixes

A short round on the round-2 fixes (snapshot b727b0b), with the boundary elements of rounds 1 and 2, the axisymmetric model, mom refined, image and closed forms. Findings:

  • W4R3B-01 (medium): two collinear wires of different ports with a small end gap ("stacked rods") were left alone, and an end gap up to the wire radius counted as meeting: rods 2 mm … 3 cm apart read +5.1e-2 … +6.4e-3 in a port entry and −20 % … −2.9 % in the transfer entry, far outside both estimates, without a message.
  • W4R3B-02, W4R3B-03 (low–medium): wires that meet at less than 30° (a V, a branch) were refused with the distance of a sample point; the 120° rule tested a piece's direction, not the turn along the chain (an arm turned by 360° counted whole, a spiral as one polyline +2.08e-3 against its windings, the jump at 120° up to −1.26e-3 for short arms).
  • W4R3B-04, W4R3B-05 (low): wires met at an axis distance of the smaller radius, not where their surfaces touch (a 2 m cross jumped by −7.5e-4); the refusal radius is that of the thickest bare wire of the world.
  • W4R3A-01 (low): mesh features merged only within the snap tolerance, so a ring axis a few picometres off an interface still read +35 … +44 % or failed, silently.
  • W4R3A-02 (low): the resistive side of the reach table had been measured above the wire for a thin ring only; a 55 mm wire under a 33 times more resistive layer read +1.72 % at 1.3 radii, unreported.

Confirmed: the graded ring block (the 113-case sweep bit for bit, 26 more worlds against the boundary elements, the estimate above every port entry), the rod-end warning once per solve, diagnose(), the costs, the cross-product axis distance, the 1.5 R and 30° switches for wires that do not meet, the thin-cover limit, the transfer estimate wherever the model holds (1.06 … 6.3 times the error), and the AP1 station and house mesh bit-identical in their radius correction.

Streams fw4r3a and fw4r3b: fixes of audits W4R3A and W4R3B

  • fw4r3b, wires end to end (W4R3B-01): pieces in line with a gap below 5 R run beside each other with the gap as their distance: a smaller R (gap / 5), or a refusal before meshing (stacked 8 mm rods up to 8.8 cm apart). Collinear pieces meet only without a gap, and a collinear piece of another port counts only where the wires meet. The coordinator first took the stream's factor 3; at 10 … 18 cm it left the transfer entry 1.15 … 1.18 times its estimate, so the factor is 5: 10 … 30 cm apart every entry lies within its estimate (R12 −2.6e-3 … −3.7e-3, 10 cm 0.47 million nodes). A rod cut into touching pieces is bit-identical.
  • fw4r3b, wires that meet (W4R3B-02, -04): wires meet where their surfaces touch, with flat ends (crossings within a1 + a2; an encased wire by its shell radius), and the window fades out to a surface gap of a1 + a2 (the cross continuous, −2.4e-5 against mom −1.6e-5). Wires that meet at 10° or more are left alone (a V of 10 … 35° on the trend of mom, polyline and two strips alike to 2e-5). The literal rule of the brief would have made wires touching along their length one conductor, with port entries that are not physical, and would have reached the D9 service drops of the generators; the coordinator set a minimum angle of 10°, below which such wires are refused as before.
  • fw4r3b, the own chain (W4R3B-03): counted whole up to a turn of 90° accumulated along it, fading linearly to 0 at 150° (the meander −1.24e-4, the spiral +5.9e-5, the 0.5 m V across 120° +3.30e-4, each next to mom; rings move by −6.9e-6 / −4.4e-7).
  • fw4r3a, mesh features (W4R3A-01): within 1e-9 of max(1 m, x) they are one line, keeping the coordinate of the physical feature (a ring touching a 1000 times more conductive layer moves by 2.6e-3 per nanometre of the interface); interfaces are cut at their own line; a zero-area triangle is an internal error. 276 gap solves lie within 1.7e-6; the 113-case sweep is bit-identical.
  • fw4r3a, the reach (W4R3A-02): the resistive side re-measured above and below the wire of five geometries with the converged thin wire (1.3 / 1.9 / 2.2 / 2.2 / 2.3 a at 3 / 10 / 33 / 100 / 1000); the conductive node at 1000 is 4.3 a; cut wires are reported from 1.3; no false positive over 727 tests, T01–T10 and 48 golden cases. The conductive nodes stay as measured at one segment length; converged, every distance lies inside them (by 0.004 … 0.17 a), so the coordinator kept the table.
  • Golden: 563 of 563 quantities identical in both streams; the AP1 station, the house mesh and the bonded L / T bit-identical.

Final documentation pass (author's request of 2026-11-16)

Before the release the author asked for a documentation that reads well, renders every formula on GitHub Pages, documents the whole public API, has getting-started examples, explains the physics, mathematics and numerics behind the methods, says when which engine is the better choice and where its limits are, and carries three case studies. Six streams worked on separate files (docstart, doctheory, docapi, docex1 … docex3), the coordinator integrated them and checked the formulas.

  • docstart: the home page, getting started (rod, ring, grid in homogeneous and two-layer soil, a fault with touch and step voltage, a profile, plots, every number asserted), concepts, glossary, units, and the decision guide Choosing an engine (decision path, accuracy against the benchmarks, cost measured on this machine, one table per engine of where it must not be used). It fixed the stale "uniform per electrode" of the engine table (one current per straight wire since Q30).
  • doctheory: one skeleton for the five engine pages (what it solves, method, numerics, accuracy, limits, the audit trail collapsed), the theory pages derived step by step, known limitations and warnings as one short entry per limit with the remedy. It found and fixed four errors (the skin-depth range, fem's support for return_to, junctions and voltage sources, a stale size notice, the quadrupole bound) and reported four outside its files (ADR-0005's skin depths, a code comment, the cim / bem names in an error message, the fem3d extra on the how-to index), which the coordinator fixed.
  • docapi: every name of the public __all__ lists (92 modules, 864 entries) is rendered with a docstring summary; 62 were on no page and 77 had no summary (constants and type aliases documented only by #: comments). tests/test_docs_api_coverage.py keeps it so.
  • docex1 … docex3: the case studies E01 (secondary substation and its LV network: 9.9 Ω alone, 0.29 Ω with 30 houses), E02 (single-family house: concrete moisture, rod, outer ring, image / mom / fem) and E03 (60 m × 40 m substation grid in two-layer soil against EN 50522, with the measures that make it pass). E02 found that a bare ring bonded 1 m outside a foundation mesh reads the touch voltage +5 … +16 % high with the image family (now in the known limitations and the safety docstring); E03 found the corner gap of the touch-voltage envelope below and the larger field errors of image_2layer over a resistive bottom (+45 % at mesh centres).
  • The envelope at the corners (author's decision): the 24 equally spaced directions of touch_voltage_envelope hit the rounded corners of the offset curve only for a square; the 60 m × 40 m grid read 12 % / 28 % low, on the unsafe side. The envelope now also stands on the arc around every corner of the convex hull of the wires (nine feet per corner, corners=True); on that grid it equals the maximum over 3600 directions to 1e-4. Square grids, rings and rods keep their maximum; corners=False reproduces the directions alone; no golden case uses the envelope.
  • Review W5E of the envelope fix: the collinearity tolerance of the hull grew with the absolute coordinates; at UTM coordinates a 20 m × 1 m outline collapsed to one straight wire and the maximum read 1.2 % low (W5E-01; the hull is built relative to the lower-left corner of the footprint). Two text corrections (W5E-02, -03). Checked correct: every corner foot at the distance to 1e-15 over many shapes and distances, the default within −0.07 % of dense sampling at the origin-scale coordinates.
  • Round 2, W5R2 (author's request): the fix holds — no maximum changes with the coordinates, no arc is lost, no sweep flips (425 705 hull vertices). Two low findings, both fixed: at projected coordinates the tolerance lay below the coordinates' round-off, so edge nodes of rotated outlines (also generated foundations) became corners and the number of feet depended on the coordinate system (64 instead of 44 at UTM; the maximum unchanged; W5R2-01: the tolerance includes 16 ulp of the largest coordinate). Five feet per 90° arc read a narrow outline 0.22 % low between two feet (W5R2-02: nine per corner, every probe within 0.001 %).
  • Formulas: a headless-Chromium render of the built site under the mike version path with the vendored MathJax found three formulas left raw (two docstrings split by a line that Markdown read as a list item), raw TeX in the table of contents of four headings with math, and a \texttt with an underscore. All fixed: 99 pages, 4540 formulas typeset, none with an error; tests/test_docs_math.py guards the three classes.
  • On the way: ruff format --check, a blocking CI step, failed on T08 and two test files on the base; fixed. The golden rebase (D8) had removed the v0.15.0 world JSON that tests/test_soil_models.py read; it is a fixture now. DIN 18014 is cited in its edition 2023-06.