CLI Reference (gm-cli)¶
All commands accept --db PATH or GROUNDMEAS_DB. Default order is GROUNDMEAS_DB, ~/.config/groundmeas/config.json, then ./groundmeas.db.
Data management¶
| function | input | output | description |
|---|---|---|---|
add-measurement |
prompts for location, method, asset, metadata | console summary | Interactive measurement creation. |
list-measurements |
none | console table | List measurements with basic metadata. |
list-items |
MEAS_ID, --type |
console table | List items for a measurement. |
add-item |
MEAS_ID, prompts |
console summary | Interactive item creation. |
edit-measurement |
MEAS_ID, prompts |
console summary | Interactive measurement edit. |
edit-item |
ITEM_ID, prompts |
console summary | Interactive item edit. |
delete-measurement |
MEAS_ID, --yes/-y |
console confirmation | Delete measurement and items. |
delete-item |
ITEM_ID, --yes/-y |
console confirmation | Delete one item. |
Import and export¶
| function | input | output | description |
|---|---|---|---|
import-json |
PATH |
console summary | Import measurements from JSON file or folder. |
export-json |
OUT.json, --measurement-id/-m |
JSON file | Export measurements to JSON. |
import-from-images |
MEAS_ID, IMAGES_DIR, options |
console or JSON | OCR import from images. |
import-omicron |
--location, --asset-type, --ze, --ut, --transferred, --soil, -D, options |
console summary | Import OMICRON COMPANO 100 / HGT1 exports (details). |
Analytics¶
| function | input | output | description |
|---|---|---|---|
distance-profile |
MEAS_ID, --type, --algorithm, --window, --frequency/-f, --conservative |
console or JSON | Reduce a distance profile. |
impedance-over-frequency |
MEAS_ID..., --profile-algorithm |
console or JSON | Frequency to impedance map. |
real-imag-over-frequency |
MEAS_ID... |
console or JSON | Frequency to real and imag map. |
rho-f-model |
MEAS_ID... |
console or JSON | Fit rho-f coefficients. |
voltage-vt-epr |
MEAS_ID..., --frequency, --profile-algorithm, --additional-resistance |
console or JSON | EPR and touch voltage summary. |
shield-currents |
LOCATION_ID, --frequency |
console or JSON | List shield currents. |
calculate-split-factor |
--earth-fault-id, --shield-id |
console or JSON | Split factor and currents. |
soil-profile |
MEAS_ID, options |
console or JSON | Depth-resistivity profile. |
soil-model |
--rho, --thickness, options |
console or JSON | Layered model and optional simulation. |
soil-inversion |
MEAS_ID, options |
console or JSON | Invert layered model. |
Plotting¶
| function | input | output | description |
|---|---|---|---|
plot-impedance |
MEAS_ID..., --normalize, --out |
image file | Impedance vs frequency plot. |
plot-rho-f-model |
MEAS_ID..., --rho-f, --rho, --out |
image file | Rho-f model plot. |
plot-voltage-vt-epr |
MEAS_ID..., --frequency, --out |
image file | EPR and touch voltage plot. |
plot-soil-model |
--rho, --thickness, --max-depth, --out |
image file | Layered soil model plot. |
plot-soil-inversion |
MEAS_ID, options, --out |
image file | Observed vs fitted resistivity plot. |
Tower campaigns (gm-cli towers)¶
| function | input | output | description |
|---|---|---|---|
towers run |
--config, --calc, --print, --zip, --stats, --worker, --no-pdf, -v/-q |
files | Evaluate a campaign (JSON, Excel, HTML/PDF protocols, ZIP, statistics). |
towers demo |
DIR, --language, --overwrite |
folder | Synthetic demo campaign. |
towers example-config |
PATH, --overwrite |
JSON file | Example configuration. |
towers flatten |
SRC, DEST, --apply, --report, --only, patterns |
files | Copy a nested delivery into the flat layout (dry run by default). |
towers import-db |
--config, --dry-run, --reimport, --timezone, --voltage-level-kv, --per-frequency |
database | Copy the instrument data of a campaign into the database. |
towers install-browser |
none | browser | Download Playwright's Chromium (needs groundmeas[pdf]). |
The towers commands do not open the database, except towers import-db.
See Tower campaigns – Command line.
Maps and dashboard¶
| function | input | output | description |
|---|---|---|---|
map |
--measurement-id/-m, --out, --open-browser |
HTML file | Generate a Folium map. |
dashboard |
none | Streamlit app | Launch the dashboard. |
Configuration¶
| function | input | output | description |
|---|---|---|---|
set-default-db |
PATH |
console confirmation | Store default DB path. |
set-default-db end-to-end (1.5.2+)¶
gm-cli set-default-db PATH writes the absolute form of PATH into the JSON
file at ~/.config/groundmeas/config.json under the "db_path" key. The
config directory is created automatically if it does not yet exist.
Resolution order for the active database path (highest priority first):
- The
GROUNDMEAS_DBenvironment variable, if set and non-empty. - The
"db_path"entry in~/.config/groundmeas/config.json. - The fallback
groundmeas.dbin the current working directory.
The dashboard, the CLI and the Streamlit UI all share this resolution chain
via :func:groundmeas.ui.dashboard.resolve_db_path (or its CLI equivalent),
so a default written via set-default-db is honoured anywhere.
# Persist the default database path for this user.
gm-cli set-default-db ~/projects/groundmeas/data/site-A.db
# Verify which path the CLI will pick (env-var overrides config).
GROUNDMEAS_DB=~/projects/groundmeas/data/site-B.db gm-cli read-measurements
To inspect the active configuration interactively:
This section documents the resolution chain and env-var precedence in one place.
Database lifecycle¶
The CLI uses :func:groundmeas.connect_db under the hood. Two notes on
its behaviour:
- Re-connect / force override.
connect_db(path)refuses to run when an engine is already initialised in the same Python process and raises :class:RuntimeError. Passforce=Trueto dispose the existing engine and rebind to a new path:
import groundmeas as gm
gm.connect_db("first.db")
# ... work ...
gm.connect_db("second.db", force=True) # replaces the engine
The gm-cli commands invoke connect_db once per process and
therefore do not normally need force=True; the override is for
long-lived Python sessions (Jupyter, Streamlit, FastAPI workers).
- Read-only filesystems.
connect_dbperforms a best-effort writability probe on the parent directory ofpathand raises :class:RuntimeError("... not writable") before SQLAlchemy is touched. NextCloud-/Dropbox-synced folders that are temporarily marked read-only and Streamlit-Cloud containers are the typical triggers. Move the database to a writable directory, pointGROUNDMEAS_DBat it, and re-run the CLI command.
When invoking the dashboard via gm-cli dashboard the same error
surfaces as an st.error panel and the dashboard halts before any
downstream query runs.
- Explicit teardown. Use :func: